Piotr Wegrzyn

Piotr Wegrzyn

Auto-generated profile, based on publicly available information

Piotr Wegrzyn

International Centre for Translational Eye Research

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 March 2022 in Biomedical Optics Express
Verified
Journal Article
Closed access
STSławomir Tomczewski
Sławomir Tomczewski
PWPiotr Węgrzyn
Piotr Węgrzyn
Dawid BoryckiDawid Borycki
Dawid Borycki
EAEgidijus Auksorius
Egidijus Auksorius
MWMaciej Wojtkowski
Maciej Wojtkowski
ACAndrea Curatolo
Andrea Curatolo
For many years electroretinography (ERG) has been used for obtaining information about the retinal physiological function. More recently, a new technique called optoretinography (ORG) has been developed. In one form of this technique, the physiological response of retinal photoreceptors to visible light, resulting in a nanometric photoreceptor optical path length change, is measured by phase-sensitive optical coherence tomography (OCT). To date, a limited number of studies with phase-based ORG measured the retinal response to a flickering light stimulation. In this work, we use a spatio-temporal optical coherence tomography (STOC-T) system to capture optoretinograms with a flickering stimulus over a 1.7 × 0.85 mm2 area of a light-adapted retina located between the fovea and the optic nerve. We show that we can detect statistically-significant differences in the photoreceptor optical path length (OPL) modulation amplitudes in response to different flicker frequencies and with better signal to noise ratios (SNRs) than for a dark-adapted eye. We also demonstrate the ability to spatially map such response to a patterned stimulus with light stripes flickering at different frequencies, highlighting the prospect of characterizing the spatially-resolved temporal-frequency response of the retina with ORG.

3 March 2020 in Optics Letters
Verified
Journal Article
Closed access
Dawid BoryckiDawid Borycki
Dawid Borycki
EAEgidijus Auksorius
Egidijus Auksorius
PWPiotr Węgrzyn
Piotr Węgrzyn
MWMaciej Wojtkowski
Maciej Wojtkowski
Spatiotemporal optical coherence (STOC) imaging is a new technique for suppressing coherent cross talk noise in Fourier-domain full-field optical coherence tomography (FD-FF-OCT). In STOC imaging, the time-varying inhomogeneous phase masks modulate the incident light to alter the interferometric signal. Resulting interference images are then processed as in standard FD-FF-OCT and averaged incoherently or coherently to produce cross-talk-free volumetric optical coherence tomography (OCT) images of the sample. Here, we show that coherent averaging is suitable when phase modulation is performed for both interferometer arms simultaneously. We explain the advantages of coherent over incoherent averaging. Specifically, we show that modulated signal, after coherent averaging, preserves lateral phase stability, enabling computational phase correction to compensate for geometrical aberrations. Ultimately, we employ it to correct for aberrations present in the image of the photoreceptor layer of the human retina that reveals otherwise invisible photoreceptor mosaics.

4 February 2022 in Optics Letters
Verified
Journal Article
Closed access
EAEgidijus Auksorius
Egidijus Auksorius
Dawid BoryckiDawid Borycki
Dawid Borycki
PWPiotr Wegrzyn
Piotr Wegrzyn
IŽIeva Žičkienė
Ieva Žičkienė
KAKarolis Adomavičius
Karolis Adomavičius
MWMaciej Wojtkowski
Maciej Wojtkowski
Fourier-domain full-field optical coherence tomography (FD-FF-OCT) is an emerging tool for high-speed eye imaging. However, cross-talk formation in images limits the imaging depth. To this end, we have recently shown that reducing spatial coherence with a fast deformable membrane can suppress the noise but over a limited axial range and with substantial data processing. Here, we demonstrate that a multimode fiber with carefully chosen parameters enables cross-talk-free imaging over a long axial range and without significant artifacts. We also show that it can be used to image the human retina and choroid in vivo with exceptional contrast.

13 February 2025 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Open access
STSławomir Tomczewski
Sławomir Tomczewski
ACAndrea Curatolo
Andrea Curatolo
AFAndrzej Foik
Andrzej Foik
PWPiotr Węgrzyn
Piotr Węgrzyn
BBBartłomiej Bałamut
Bartłomiej Bałamut
MWMaciej Wojtkowski
Maciej Wojtkowski
In this study, we used an inhibitor of phosphodiesterase 6 (PDE6) to examine the impact of changes in the conformation of the PDE6 protein on the light-induced process responsible for altering the length of the outer segments of photoreceptor cells in both human and rodent eyes. We employed a imaging method called spatiotemporal optical coherence tomography, which ensures high contrast and phase stability within the strongly scattering photoreceptor– Retinal Pigment Epithelium complex. Using this approach, we recorded nanometer-scale changes in human cones and rods in response to photopic flicker stimulation and observed length changes in rodent rods under scotopic conditions following a single pulse of light, in the absence or presence of sildenafil, which inhibits the catalytic activity of PDE6. Our findings are consistent with the interpretation that during phototransduction conformational changes in PDE6 structure, which occur on an angstrom scale, are amplified to the nanometer scale due to the unique structure of the photoreceptor outer segments and sequential stimulation. This finding opens up possibilities for the informed use of photopic flicker optoretinography measurements as a diagnostic tool, as the observed nanometer-scale changes in rod and cone dimensions as a function of light stimulus can now be directly linked to molecular events involved in the phototransduction pathway.

30 April 2024 in Optics Letters
Verified
Journal Article
Open access
STSławomir Tomczewski
Sławomir Tomczewski
PWPiotr Węgrzyn
Piotr Węgrzyn
MWMaciej Wojtkowski
Maciej Wojtkowski
ACAndrea Curatolo
Andrea Curatolo
Flicker electroretinography (ERG) has served as a valuable noninvasive objective tool for investigating retinal physiological function through the measurement of electrical signals originating from retinal neurons in response to temporally modulated light stimulation. Deficits in the response at certain frequencies can be used as effective biomarkers of cone-pathway dysfunction. In this Letter, we present the progress we made on its optical counterpart—photopic flicker optoretinography (f-ORG). Specifically, we focus on the measurement of the response of light-adapted retinal photoreceptors to a flicker stimulus with chirped frequency modulation. In contrast to measurements performed at discrete frequencies, this technique enables a significantly accelerated characterization of photoreceptor outer segment optical path length modulation amplitudes in the nanometer range as a function of stimulus frequency, enabling the acquisition of the characteristic frequency response in less than 2 sec.

1 October 2024 in Neurophotonics
Verified
Journal Article
Open access
PDF file
PWPiotr Węgrzyn
Piotr Węgrzyn
WKWiktor Kulesza
Wiktor Kulesza
MWMaciej Wielgo
Maciej Wielgo
STSławomir Tomczewski
Sławomir Tomczewski
AGAnna Galińska
Anna Galińska
ACAndrea Curatolo
Andrea Curatolo
SignificanceMicrocirculation and neurovascular coupling are important parameters to study in neurological and neuro-ophthalmic conditions. As the retina shares many similarities with the cerebral cortex and is optically accessible, a special focus is directed to assessing the chorioretinal structure, microvasculature, and hemodynamics of mice, a vital animal model for vision and neuroscience research.AimWe aim to introduce an optical imaging tool enabling in vivo volumetric mouse retinal monitoring of vascular hemodynamics with high temporal resolution.ApproachWe translated the spatio-temporal optical coherence tomography (STOC-T) technique into the field of small animal imaging by designing a new optical system that could compensate for the mouse eye refractive error. We also developed post-processing algorithms, notably for the assessment of (i) localized hemodynamics from the analysis of pulse wave–induced Doppler artifact modulation and (ii) retinal tissue displacement from phase-sensitive measurements.ResultsWe acquired high-quality, in vivo volumetric mouse retina images at a rate of 113 Hz over a lateral field of view of ∼500 μm. We presented high-resolution en face images of the retinal and choroidal structure and microvasculature from various layers, after digital aberration correction. We were able to measure the pulse wave velocity in capillaries of the outer plexiform layer with a mean speed of 0.35 mm/s and identified venous and arterial pulsation frequency and phase delay. We quantified the modulation amplitudes of tissue displacement near major vessels (with peaks of 150 nm), potentially carrying information about the biomechanical properties of the retinal layers involved. Last, we identified the delays between retinal displacements due to the passing of venous and arterial pulse waves.ConclusionsThe developed STOC-T system provides insights into the hemodynamics of the mouse retina and choroid that could be beneficial in the study of neurovascular coupling and vasculature and flow speed anomalies in neurological and neuro-ophthalmic conditions.