4 May 2023 in Chemical Reviews
16 January 2022 in ACS Applied Materials & Interfaces
11 July 2016 in Journal of Applied Physics
The effects of gamma irradiation on the dielectric and piezoelectric responses of Pb[Zr0.52Ti0.48]O3 (PZT) thin film stacks were investigated for structures with conductive oxide (IrO2) and metallic (Pt) top electrodes. The samples showed, generally, degradation of various key dielectric, ferroelectric, and electromechanical responses when exposed to 2.5 Mrad (Si) 60Co gamma radiation. However, the low-field, relative dielectric permittivity, εr, remained largely unaffected by irradiation in samples with both types of electrodes. Samples with Pt top electrodes showed substantial degradation of the remanent polarization and overall piezoelectric response, as well as pinching of the polarization hysteresis curves and creation of multiple peaks in the permittivity-electric field curves post irradiation. The samples with oxide electrodes, however, were largely impervious to the same radiation dose, with less than 5% change in any of the functional characteristics. The results suggest a radiation-induced change in the defect population or defect energy in PZT with metallic top electrodes, which substantially affects motion of internal interfaces such as domain walls. Additionally, the differences observed for stacks with different electrode materials implicate the ferroelectric–electrode interface as either the predominant source of radiation-induced effects (Pt electrodes) or the site of healing for radiation-induced defects (IrO2 electrodes).
28 November 2023 in Chemistry of Materials
Linear and nonlinear optical line shapes reveal details of excitonic structure in polymer semiconductors. We implement absorption, photoluminescence, and transient absorption spectroscopies in DPP-DTT, an electron push-pull copolymer, to explore the relationship between their spectral line shapes and chain conformation, deduced from resonance Raman spectroscopy and from ab initio calculations. The viscosity of precursor polymer solutions before film casting displays a transition that suggests gel formation above a critical concentration. Upon crossing this viscosity deflection concentration, the line shape analysis of the absorption spectra within a photophysical aggregate model reveals a gradual increase in interchain excitonic coupling. We also observe a red-shifted and line-narrowed steady-state photoluminescence spectrum along with increasing resonance Raman intensity in the stretching and torsional modes of the dithienothiophene unit, which suggests a longer exciton coherence length along the polymer-chain backbone. Furthermore, we observe a change of line shape in the photoinduced absorption component of the transient absorption spectrum. The derivative-like line shape may originate from two possibilities: a new excited-state absorption or Stark effect, both of which are consistent with the emergence of a high-energy shoulder as seen in both photoluminescence and absorption spectra. Therefore, we conclude that the exciton is more dispersed along the polymer chain backbone with increasing concentrations, leading to the hypothesis that polymer chain order is enhanced when the push-pull polymers are processed at higher concentrations. Thus, tuning the microscopic chain conformation by concentration would be another factor of interest when considering the polymer assembly pathways for pursuing large-area and high-performance organic optoelectronic devices.
15 September 2021 in Journal of Polymer Science
13 June 2016 in Applied Physics Letters
The influence of surface morphology on the local piezoelectric response of highly (100)-textured 0.70PbMg2/3Nb1/3O3-0.30PbTiO3 thin films is studied using piezoresponse force microscopy in band-excitation mode. The local electromechanical response is mostly suppressed in direct proximity of the grain boundaries. However, within 100–200 nm of the grain boundary, the piezoresponse is substantially enhanced, before decaying again within a region at the center of the grain itself. Nested piezoresponse hysteresis curves confirm the influence of topography descriptors on parameters affecting the hysteresis loop shape. The enhancement of the electromechanical response is rationalized through reduced lateral clamping in the grains with deep trenched boundaries, as well as an expected lower energy for complex domain wall structures, due to curved ferroelectric surfaces. The lower piezoresponse at the center of the grain is assigned to the lateral clamping by the surrounding piezoelectric material.