Thao Pham

Thao Pham

Auto-generated profile, based on publicly available information

Thao Pham

Boston University, Department of Biomedical Engineering, Boston, Massachusetts, United States

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 March 2019 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
TPThao Pham
Thao Pham
KTKristen Tgavalekos
Kristen Tgavalekos
ASAngelo Sassaroli
Angelo Sassaroli
GBGiles Blaney
Giles Blaney
SFSergio Fantini
Sergio Fantini
We propose a new near-infrared spectroscopy (NIRS) method for quantitative measurements of cerebral blood flow (CBF). Because this method uses concepts of coherent hemodynamics spectroscopy (CHS), we identify this new method with the acronym NIRS-CHS. We tested this method on the prefrontal cortex of six healthy human subjects during mean arterial pressure (MAP) transients induced by the rapid deflation of pneumatic thigh cuffs. A comparison of CBF dynamics measured with NIRS-CHS and with diffuse correlation spectroscopy (DCS) showed a good agreement for characteristic times of the CBF transient. We also report absolute measurements of baseline CBF with NIRS-CHS (69 ± 6 ml/100g/min over the six subjects). NIRS-CHS can provide more accurate measurements of CBF with respect to previously reported NIRS surrogates of CBF.

7 January 2021 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
BLBoyang Lyu
Boyang Lyu
TPThao Pham
Thao Pham
GBGiles Blaney
Giles Blaney
ZHZachary Haga
Zachary Haga
ASAngelo Sassaroli
Angelo Sassaroli
SAShuchin Aeron
Shuchin Aeron
Functional near-infrared spectroscopy (fNIRS) is a noninvasive optical technique for monitoring regional tissue oxygenation based on diffusion and absorption of near-infrared light photons in human tissue. Continuous-wave (cw) fNIRS provides measurements of concentration changes in oxy-, deoxy-, and total-hemoglobin species (Δ[HbO2], Δ[Hb], and Δ[HbT], respectively) in tissue with temporal sampling rate of on the order of 10 Hz.1 Over the past three decades, fNIRS has been used in several brain imaging applications, including noninvasive imaging of cognitive tasks and brain functional activation,1 – 4 and brain computer interface (BCI).5

16 February 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
GBGiles Blaney
Giles Blaney
RDRyan Donaldson
Ryan Donaldson
SMSamee Mushtak
Samee Mushtak
HNHan Nguyen
Han Nguyen
LVLydia Vignale
Lydia Vignale
Sergio FantiniSergio Fantini
Sergio Fantini
This work presents the design and validation of an instrument for dual-slope broadband diffuse reflectance spectroscopy. This instrument affords calibration-free, continuous-wave measurements of broadband absorbance of optically diffusive media, which may be translated into absolute absorption spectra by adding frequency-domain measurements of scattering at two wavelengths. An experiment on a strongly scattering liquid phantom (milk, water, dyes) confirms the instrument’s ability to correctly identify spectral features and measure absolute absorption. This is done by sequentially adding three dyes, each featuring a distinct spectral absorption, to the milk/water phantom. After each dye addition, the absorption spectrum is measured, and it is found to reproduce the spectral features of the added dye. Additionally, the absorption spectrum is compared to the absorption values measured with a commercial frequency-domain instrument at two wavelengths. The measured absorption of the milk/water phantom quantitatively agrees with the known water absorption spectrum (R2=0.98), and the measured absorption of the milk/water/dyes phantom quantitatively agrees with the absorption measured with the frequency-domain instrument in six of eight cases. Additionally, the measured absorption spectrum correctly recovers the concentration of one dye, black India ink, for which we could accurately determine the extinction spectrum (i.e., the specific absorption per unit concentration). The instrumental methods presented in this work can find applications in quantitative spectroscopy of optically diffusive media, and particularly in near-infrared spectroscopy of biological tissue.

26 July 2019 in Photonics
Verified
Journal Article
Open access
PDF file
GBGiles Blaney
Giles Blaney
ASAngelo Sassaroli
Angelo Sassaroli
TPThao Pham
Thao Pham
NKNishanth Krishnamurthy
Nishanth Krishnamurthy
Sergio FantiniSergio Fantini
Sergio Fantini
We report non-invasive, bilateral optical measurements on the forehead of five healthy human subjects, of 0.1 Hz oscillatory hemodynamics elicited either by cyclic inflation of pneumatic thigh cuffs, or by paced breathing. Optical intensity and the phase of photon-density waves were collected with frequency-domain near-infrared spectroscopy at seven source-detector distances (11–40 mm). Coherent hemodynamic oscillations are represented by phasors of oxyhemoglobin (O) and deoxyhemoglobin (D) concentrations, and by the vector D/O that represents the amplitude ratio and phase difference of D and O. We found that, on an average, the amplitude ratio (|D/O|) and the phase difference (∠(D/O)) obtained with single-distance intensity at 11–40 mm increase from 0.1° and −330° to 0.2° and −200°, respectively. Single-distance phase and the intensity slope featured a weaker dependence on source-detector separation, and yielded |D/O| and ∠(D/O) values of about 0.5 and −200°, respectively, at distances greater than 20 mm. The key findings are: (1) Single-distance phase and intensity slope are sensitive to deeper tissue compared to single-distance intensity; (2) deeper tissue hemodynamic oscillations, which more closely represent the brain, feature D and O phasors that are consistent with a greater relative flow-to-volume contributions in brain tissue compared to extracerebral, superficial tissue.

15 November 2018 in Journal of Biomedical Optics
Verified
Journal Article
Closed access
PDF file
KKKosar Khaksari
Kosar Khaksari
GBGiles Blaney
Giles Blaney
ASAngelo Sassaroli
Angelo Sassaroli
NKNishanth Krishnamurthy
Nishanth Krishnamurthy
TPThao Pham
Thao Pham
Sergio FantiniSergio Fantini
Sergio Fantini
We report a near-infrared spectroscopy (NIRS) study of coherent hemodynamic oscillations measured on the human forehead at multiple source–detector distances (1 to 4 cm). The physiological source of the coherent hemodynamics is arterial blood pressure oscillations at a frequency of 0.1 Hz, induced by cyclic inflation (to a pressure of 200 mmHg) and deflation of two thigh cuffs wrapped around the subject’s thighs. To interpret our results, we use a recently developed hemodynamic model and a phasor representation of the oscillations of oxyhemoglobin, deoxyhemoglobin, and total hemoglobin concentrations in the tissue (phasors O, D, and T, respectively). The increase in the phase angle between D and O at larger source–detector separations is assigned to greater flow versus volume contributions and to a stronger blood flow autoregulation in deeper tissue (brain cortex) with respect to superficial tissue (scalp and skull). The relatively constant phase lag of T versus arterial blood pressure oscillations at all source–detector distances was assigned to competing effects from stronger autoregulation and smaller arterial-to-venous contributions in deeper tissue with respect to superficial tissue. We demonstrate the application of a hemodynamic model to interpret coherent hemodynamics measured with NIRS and to assess the different nature of shallow (extracerebral) versus deep (cerebral) tissue hemodynamics.

10 November 2025 in Biomedical Optics Express
Verified
Journal Article
Closed access
DRDarren Roblyer
Darren Roblyer
APAnahita Pilvar
Anahita Pilvar
TPThao Pham
Thao Pham
SSSamuel Spink
Samuel Spink
CHCarole K. Hayakawa
Carole K. Hayakawa
MPMark Pierce
Mark Pierce
The shortwave infrared (SWIR) wavelength band (1,000–2,000 nm) has recently garnered increased interest due to its beneficial attributes for tissue imaging and spectroscopy. Lower scattering, increased sensitivity to endogenous water and lipid content, and the reduced influence of melanin offer new measurement opportunities and application areas. SWIR sensor technology is advancing at a rapid pace, fueling growth in academic and commercial instrument development. Here, we review recent progress in SWIR tissue imaging and spectroscopy, provide resources on tissue optical properties at SWIR wavelengths, and offer guidance on the utilization of models, methods, and instruments for SWIR measurements in tissue. One key finding is that while some efforts have exploited the lower scattering in the SWIR to achieve deep tissue imaging, this advantage is highly dependent on the specific choice of wavelength and the measurement geometry. Photon attenuation limits these advantages at wavelengths where water absorption is strong, especially in the context of higher-noise SWIR detectors. However, a growing number of clinical applications are emerging, especially those requiring in vivo water and lipid measurements, such as monitoring of tissue hydration, edema, lipid content, and others. There are further opportunities to expand this work toward more disease states while leveraging the low absorption of melanin in the SWIR. Since the field is currently limited by relatively few sources of tissue optical property data at SWIR wavelengths, we have compiled tabulated extinction values of SWIR chromophores from the literature. There is also a need for continued development of techniques for modeling photon propagation in tissue at SWIR wavelengths due to more moderate levels of tissue scattering compared to absorption, and methods to establish stable tissue-mimicking phantoms. The SWIR wavelength region is coming of age in the biophotonics community, with components and systems creating new opportunities in basic research and clinical applications once current challenges can be overcome.