Within the article, a preeroded copper cathode was subjected to the impact of a series of high-voltage pulses with a duration of $<$ 1 ns for surface conditioning. An effective cathode surface area was $\sim$ 0.01 mm $^{2}$ . Preerosion of the cathode surface was performed using a series of vacuum arc discharges of microsecond duration. As a result, a well-pronounced microrelief with a typical dimension of $\sim$ 5–10 $\mu $ m was formed at the cathode surface. Then, to smooth the microrelief, the cathode was placed into a vacuum setup based on a RADAN pulse generator with a pulse duration of $<$ 1 ns and a pulse amplitude of up to $-$ 140 kV. About 900 discharges of a subnanosecond duration were initiated. To estimate the conditioning effectiveness, the state of the cathode surface was controlled by studying the cathode field-emission characteristics and cathode surface imaging by scanning electron microscopy (SEM). The field-emission characteristic study made it possible to estimate the electric field enhancement factor $\beta $ near the cathode surface before and after the conditioning. It was shown that the subnanosecond conditioning led to a decrease in $\beta $ by a factor of 6–8 from $\sim$ 170 after eroding to $\sim$ 20–30. Employing SEM investigation of the sample surface morphology, it was found that a typical microrelief dimension was decreased from $\sim$ 5–10 to $\sim$ 1–2 $\mu $ m or less. That is, a proposed conditioning technique allowed significant smoothing of the cathode surface.
An experiment was performed to estimate the diameters and formation times of the craters formed during the operation of a cathode spot cell in a vacuum arc. The obtained experimental data and the relevant data available in the literature are analyzed within the framework of a two-dimensional axisymmetric model developed to investigate the crater formation on a cathode, which takes into account the finite lifetime of the cathode spot cell. The model is described by the Navier–Stokes equations for a viscous incompressible fluid with a free surface and the heat conduction equation taking into account convective heat transfer. The parameters of the interaction of the cathode spot plasma with the cathode surface are chosen in the process of simulation based on an analysis of experimental data on the parameters and mechanism of crater formation. The changes in the cathode shape caused by the motion of the molten metal under the action of the plasma pressure are calculated from the onset of melting. As a result of the simulation, the main geometric parameters of a crater (diameter and depth) and their formation time have been estimated as functions of the lifetime of the cathode spot cell.
8 September 2022 in IEEE Transactions on Plasma Science
Research of the tungsten “fuzz” emission properties and dielectric strength was carried out. A “fuzzy” sample was made through He+ ion exposure of an initially polished tungsten surface using an inductively coupled plasma (ICP) facility. The eventual He+ ion fluence was $\sim 1.7\times 10^{25}\,\,\text{m}^{-2}$ . The induced nanostructured layer thickness was estimated to be $\sim 1~\mu \text{m}$ . The measurements were performed with an automated experimental setup developed. The setup was operated under the control of the programmable DAC/ADC module “LCard E20-10.” As a result, the untypical behavior of a nanostructured cathode in comparison with an ordinary field emissive cathode was registered. Instability of the W “fuzz” emission properties was demonstrated. Typical values of the electric field enhancement factor were found to be in the range of ~120–200 both before a single breakdown and after it. These values are in agreement with the estimations of the enhancement factor performed with taking into account the geometry of protrude cathode structures. Stabilization of the emission properties after the breakdown was observed. The conditioning effect of the nanostructured cathode was found to take place after approximately five breakdowns. After conditioning, an asymptotic value of a breakdown electric field strength was $\sim 8.5\times 10^{7}$ V/m, which is in agreement with the one for an ordinary tungsten cathode. The conditioning effect and the emission current stabilization are believed to be due to the destruction of the nanostructure under the impact of the breakdowns.
1 December 2023 in Bulletin of the Russian Academy of Sciences: Physics
A multifactorial investigation of the influence of vacuum discharge parameters on the copper cathode emission properties was carried out. The object of the study was an initially smooth surface of copper cathodes obtained by melting tips of copper needles in a vacuum. A typical radius of the cathode tip was 25–30 µm. The cathodes were subjected to vacuum arc discharges of submicrosecond duration with a current amplitude in the range of tens of amperes. After each discharge, the cathode was placed into a field-emission projector inside the same vacuum chamber without breaking the vacuum conditions. An automated measuring system was connected to the projector to obtain the current-voltage characteristics of the field emission. According to the current-voltage characteristics, the electric field enhancement factor on the surface of the emitter was estimated. This estimation, accompanied by the scanning electron microscopy analysis of the sample surface, showed an increase in the typical dimension of the microrelief objects and the local electric field enhancement factor with the arc discharge current value.
1 November 2019 in Journal of Physics: Conference Series
The dependence of the ion flux mass-charge composition from the vacuum arc plasma with the CuCr cathode on a value of the discharge current was investigated via the Thomson spectrometer with automatic signal registration and analysis. The microsecond arc was formed in a millimeter gap between CuCr cathode and copper anode under high vacuum conditions. The arc current was changed within the range from a few to tens of ampere. At the highest currents the plasma composition corresponded the elemental composition of the cathode surface. The fraction of the chromium ions significantly decreased with the arc current decreasing below 30 A. There was noticeable increasing of the fraction of the chromium ions in the plasma at the discharge currents near the threshold values for the cathode materials. The effect appeared on coarse-grained non-melted cathode surfaces, and vanished after a multiple arcing.