17 September 2019 in Indoor and Built Environment
A field investigation on indoor environmental conditions was performed in homes with primary school children in Changsha, a city located in central-south China. The main purpose is to obtain more reliable and comprehensive data relating to the health of children. The results showed that the average temperature, relative humidity and carbon dioxide concentration in October were 20.4°C, 56.7% and 398 ppm, while in January were 10.5°C, 55% and 475 ppm, respectively. The monitored PM2.5 concentrations were greater than the Chinese national standard GB 3095–2012 (75 μg/m3), with a significant difference found between October and January ( p < 0.05). Carbonyl compounds were much lower than the corresponding specified limits. However, total volatile organic compounds (TVOCs) in some homes in January exceeded the Chinese standard GB/T 18883–2002 (600 μg/m3). The most common constituents of semi-volatile organic compounds in house dusts were di(2-ethylhexyl) phthalate and dibutyl phthalate. Furthermore, Cladosporium, Penicillium and Aspergillus were all found in indoor air and house dusts. Children’s daily intake of formaldehyde, acetaldehyde and TVOC were primary from their bedrooms rather than living rooms ( p < 0.05). These results would contribute to the public awareness of indoor environmental conditions and possible impacts on school-age children in their homes.
9 August 2024 in Case Studies in Thermal Engineering
8 October 2020 in Geofluids
Mining activities have increased owing to the rise in the social demand for minerals. Thermal hazards have become a major health and safety consideration in mines. The thermal environment of a working face is related to the air parameters at the bottom of shaft. The objective of this study is to accurately predict the air temperature at the bottom of a shaft in a mine with the ventilation time over 3 years. For this purpose, a mathematical model of the heat and mass exchange between the surrounding rock of the shaft and the downcast air is established by utilizing the finite volume method. The C++ languages are used for numerical calculations. The results are in agreement with the measured data. The effects of the relative humidity of air at the inlet of the shaft, the surface moisture coefficient of the shaft surface, and the physical parameters of the rock on the air parameters at the shaft bottom are studied in detail. Equations for calculating the enthalpy increase of air per 100 m in shaft with the depth of 1300 m were established by using cluster analysis. This equation provides a theoretical basis for predicting the air parameters along the shaft with the ventilation time over 3 years.
28 July 2016 in Indoor and Built Environment
A new comprehensive evaluation method for assessing the sustainability credential of central air-conditioning systems is proposed in this paper. The method is based on the relative coefficient index (K) of costs and benefits of the air-conditioning system. The paper introduces the concept and defined the parameters of costs (energy consumption costs, economic running costs and environmental impact) and benefits (indoor air quality and thermal comfort) and the mathematical principles for the determination and evaluation of these parameters. The parameters are then ranked with an index value for each component that make up the air-conditioning system, and the total index value would be used for the overall evaluation of the costs and benefits to determine the overall index, K. The feasibility of the method is illustrated by three case studies included in this paper. The evaluation index can identify shortcomings of components in the air-conditioning system and to identify the relative environmental impacts and costs as well as the performance in using the system. The evaluation index would thus allow designers and building managers to target performance improvements and guide designers to optimize functions in terms of costs and benefits to minimize environmental impacts. The index method would provide a rating classification of air-conditioning systems for standard specification and selection in terms of cost effectiveness for appropriate building service required.
17 October 2022 in Case Studies in Thermal Engineering