Greater attention is currently being paid to the relationship between indoor environment and childhood allergies, however, the lack of reliable data and the disparity among different areas hinders reliable assessment of the relationship. This study focuses on the effect of indoor pollution on Chinese schoolchildren and the relationship between specific household and health problems suffered. The epidemiological questionnaire survey and the field measurement of the indoor thermal environment and primary air pollutants including CO2, fine particulate matter (PM2.5), chemical pollutants and fungi were performed in six Chinese cities. A total of 912 questionnaires were eligible for statistical analyses and sixty houses with schoolchildren aged 9–12 were selected for field investigation. Compared with Chinese national standards, inappropriate indoor relative humidity (70%), CO2 concentration exceeding 1000 ppm and high PM2.5 levels were found in some monitored houses. Di(2-ethylhexyl) phthalate (DEHP) and dibutyl phthalate (DBP) were the most frequently detected semi-volatile organic compounds (SVOCs) in house dust. Cladosporium, Aspergillus and Penicillium were detected in both indoor air and house dust. This study indicates that a thermal environment with CO2 exceeding 1000 ppm, DEHP and DBP exceeding 1000 μg/g, and high level of PM2.5, Cladosporium, Aspergillus and Penicillium increases the risk of children’s allergies.
As one of the most widely used units in water cooling systems, the closed wet cooling towers (CWCTs) have two typical counter-flow constructions, in which the spray water flows from the top to the bottom, and the moist air and cooling water flow in the opposite direction vertically (parallel) or horizontally (cross), respectively. This study aims to present a simplified calculation method for conveniently and accurately analyzing the thermal performance of the two types of counter-flow CWCTs, viz. the parallel counter-flow CWCT (PCFCWCT) and the cross counter-flow CWCT (CCFCWCT). A simplified cooling capacity model that just includes two characteristic parameters is developed. The Levenberg–Marquardt method is employed to determine the model parameters by curve fitting of experimental data. Based on the proposed model, the predicted outlet temperatures of the process water are compared with the measurements of a PCFCWCT and a CCFCWCT, respectively, reported in the literature. The results indicate that the predicted values agree well with the experimental data in previous studies. The maximum absolute errors in predicting the process water outlet temperatures are 0.20 and 0.24 °C for the PCFCWCT and CCFCWCT, respectively. These results indicate that the simplified method is reliable for performance prediction of counter-flow CWCTs. Although the flow patterns of the two towers are different, the variation trends of thermal performance are similar to each other under various operating conditions. The inlet air wet-bulb temperature, inlet cooling water temperature, air flow rate, and cooling water flow rate are crucial for determining the cooling capacity of a counter-flow CWCT, while the cooling tower effectiveness is mainly determined by the flow rates of air and cooling water. Compared with the CCFCWCT, the PCFCWCT is much more applicable in a large-scale cooling water system, and the superiority would be amplified when the scale of water distribution system increases. Without multiple iterative calculations and extensive experimental data, the simplified method could be used to effectively analyze the thermal performance of counter-flow CWCTs in operation. It is useful for optimization operation of counter-flow CWCTs such that to improve the energy efficiency of the overall cooling water system.
A field investigation on indoor environmental conditions was performed in homes with primary school children in Changsha, a city located in central-south China. The main purpose is to obtain more reliable and comprehensive data relating to the health of children. The results showed that the average temperature, relative humidity and carbon dioxide concentration in October were 20.4°C, 56.7% and 398 ppm, while in January were 10.5°C, 55% and 475 ppm, respectively. The monitored PM2.5 concentrations were greater than the Chinese national standard GB 3095–2012 (75 μg/m3), with a significant difference found between October and January ( p < 0.05). Carbonyl compounds were much lower than the corresponding specified limits. However, total volatile organic compounds (TVOCs) in some homes in January exceeded the Chinese standard GB/T 18883–2002 (600 μg/m3). The most common constituents of semi-volatile organic compounds in house dusts were di(2-ethylhexyl) phthalate and dibutyl phthalate. Furthermore, Cladosporium, Penicillium and Aspergillus were all found in indoor air and house dusts. Children’s daily intake of formaldehyde, acetaldehyde and TVOC were primary from their bedrooms rather than living rooms ( p < 0.05). These results would contribute to the public awareness of indoor environmental conditions and possible impacts on school-age children in their homes.
The impacts of greenery systems (GSs) on microclimate conditions and building energy performance have been frequently investigated using experiments and simulations during the past decades, especially in summer and winter. However, few studies have focused on the performance of GSs in transition seasons. The ambient weather conditions vary with great fluctuations during transition seasons, which may result in severe oscillations in indoor environments. To investigate the impacts of GSs on indoor environments, an experiment was conducted using a contrastive test platform, which consisted of two experimental rooms, one equipped with a GS and the other without, from 1 April 2019 to 31 May 2019 in Hunan, China. Both rooms were free-running. The experimental results showed that the GS had the ability to reduce the oscillations in the indoor environment. The oscillations in indoor dry-bulb temperature (DBT) and relative humidity (RH) were reduced by 39.3% and 28.8%, respectively. The maximum daily DBT and RH ranges were, respectively, cut down by 3.5 °C and 12.4%. The maximum reductions in external and internal surface temperatures were 29.5 °C and 9.4 °C, respectively, for the GS, while the average reductions were 1.6~4.1 °C and 0.2~1.3 °C, respectively, depending on the orientation of the surfaces. The operative temperature (OT) during the daytime on sunny days was also lowered by the GS. The differences in OT between the two rooms ranged from −1.8 °C to 8.2 °C, with an average of 1.0 °C. The GS can improve the indoor thermal comfort during transition seasons. The thermal dissatisfaction was decreased by 7.9%. This lengthened the thermal comfort time by 15% across the whole day and by 28% during the daytime. This indicates reductions in air-conditioning system operating times, leading to energy savings.
An existing idle cooling tower can be reversibly used as a heat-source tower (HST) to drive a heat pump (HP) in cold seasons, with calcium chloride (CaCl2) aqueous solution commonly selected as the secondary working fluid in an indirect system due to its good thermo-physical properties. This study analyzed the effect of CaCl2 mass fraction on the effectiveness (ε) of a closed HST and the coefficient of performance (COP) of a HP heating system using an artificial neural network (ANN) technique. CaCl2 aqueous solutions with five different mass fractions, viz. 3%, 9%, 15%, 21%, and 27%, were chosen as the secondary working fluids for the HSTHP heating system. In order to collect enough measured data, extensive field tests were conducted on an experimental test rig in Changsha, China which experiences hot summer and cold winter weather. After back-propagation (BP) training, the three-layer (4-9-2) ANN model with a tangent sigmoid transfer function at the hidden layer and a linear transfer function at the output layer was developed for predicting the tower effectiveness and the COP of the HP under different inlet air dry-/wet-bulb temperatures, hot water inlet temperatures and CaCl2 mass fractions. The correlation coefficient (R), mean relative error (MRE) and root mean squared error (RMSE) were adopted to evaluate the prediction accuracy of the ANN model. The results showed that the R, MRE, and RMSE between the training values and the experimental values of ε (COP) were 0.995 (0.996), 2.09% (1.89%), and 0.005 (0.060), respectively, which indicated that the ANN model was reliable and robust in predicting the performance of the HP. The findings of this paper indicated that in order to guarantee normal operation of the system, the freezing point temperature of the CaCl2 aqueous solution should be sufficiently (3–5 K) below its lowest operating temperature or lower than the normal operating temperature by about 10 K. The tower effectiveness increased with increasing CaCl2 mass fraction from 0 to 27%, while the COP of the HP decreased. A tradeoff between the tower effectiveness and the COP of the HP should be considered to further determine the suitable mass fraction of CaCl2 aqueous solution for the HSTHP heating system. The outputs of this study are expected to provide guidelines for selecting brine with an appropriate mass fraction for a closed HSTHP heating system for actual applications, which would be a reasonable solution to improve the system performance.