Divyanshu Mishra

Divyanshu Mishra

Auto-generated profile, based on publicly available information

Divyanshu Mishra

Institute of Biomedical Engineering, Department of Engineering Science, University of Oxford, Oxford, OX3 7DQ, United Kingdom

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2022 in JMIR Research Protocols
Verified
Journal Article
Open access
ASAlice Self
Alice Self
QCQingchao Chen
Qingchao Chen
BDBapu Koundinya Desiraju
Bapu Koundinya Desiraju
SDSumeet Dhariwal
Sumeet Dhariwal
AGAlexander D Gleed
Alexander D Gleed
JNJ Alison Noble
J Alison Noble
Background: The World Health Organization recommends a package of pregnancy care that includes obstetric ultrasound scans. There are significant barriers to universal access to antenatal ultrasound, particularly because of the cost and need for maintenance of ultrasound equipment and a lack of trained personnel. As low-cost, handheld ultrasound devices have become widely available, the current roadblock is the global shortage of health care providers trained in obstetric scanning. Objective: The aim of this study is to improve pregnancy and risk assessment for women in underserved regions. Therefore, we are undertaking the Computer-Assisted Low-Cost Point-of-Care UltraSound (CALOPUS) project, bringing together experts in machine learning and clinical obstetric ultrasound. Methods: In this prospective study conducted in two clinical centers (United Kingdom and India), participating pregnant women were scanned and full-length ultrasounds were performed. Each woman underwent 2 consecutive ultrasound scans. The first was a series of simple, standardized ultrasound sweeps (the CALOPUS protocol), immediately followed by a routine, full clinical ultrasound examination that served as the comparator. We describe the development of a simple-to-use clinical protocol designed for nonexpert users to assess fetal viability, detect the presence of multiple pregnancies, evaluate placental location, assess amniotic fluid volume, determine fetal presentation, and perform basic fetal biometry. The CALOPUS protocol was designed using the smallest number of steps to minimize redundant information, while maximizing diagnostic information. Here, we describe how ultrasound videos and annotations are captured for machine learning. Results: Over 5571 scans have been acquired, from which 1,541,751 label annotations have been performed. An adapted protocol, including a low pelvic brim sweep and a well-filled maternal bladder, improved visualization of the cervix from 28% to 91% and classification of placental location from 82% to 94%. Excellent levels of intra- and interannotator agreement are achievable following training and standardization. Conclusions: The CALOPUS study is a unique study that uses obstetric ultrasound videos and annotations from pregnancies dated from 11 weeks and followed up until birth using novel ultrasound and annotation protocols. The data from this study are being used to develop and test several different machine learning algorithms to address key clinical diagnostic questions pertaining to obstetric risk management. We also highlight some of the challenges and potential solutions to interdisciplinary multinational imaging collaboration. International Registered Report Identifier (IRRID): RR1-10.2196/37374

2 May 2025 in Medical Image Analysis
Verified
Journal Article
Closed access
DMDivyanshu Mishra
Divyanshu Mishra
PSPramit Saha
Pramit Saha
HZHe Zhao
He Zhao
Netzahualcoyotl Hernandez-CruzNetzahualcoyotl Hernandez-Cruz
Netzahualcoyotl Hernandez-Cruz
OPOlga Patey
Olga Patey
JNJ. Alison Noble
J. Alison Noble

23 December 2025 in Information Fusion
Verified
Journal Article
Open access
PSPramit Saha
Pramit Saha
DMDivyanshu Mishra
Divyanshu Mishra
FWFelix Wagner
Felix Wagner
KKKonstantinos Kamnitsas
Konstantinos Kamnitsas
JNJ. Alison Noble
J. Alison Noble

26 August 2025 in Medical Image Analysis
Verified
Journal Article
Open access
Md Mostafa Kamal SarkerMd Mostafa Kamal Sarker
Md Mostafa Kamal Sarker
DMDivyanshu Mishra
Divyanshu Mishra
MAMohammad Alsharid
Mohammad Alsharid
Netzahualcoyotl Hernandez-CruzNetzahualcoyotl Hernandez-Cruz
Netzahualcoyotl Hernandez-Cruz
RARahul Ahuja
Rahul Ahuja
JNJ. Alison Noble
J. Alison Noble
Fetal echocardiography offers non-invasive and real-time imaging acquisition of fetal heart images to identify congenital heart conditions. Manual acquisition of standard heart views is time-consuming, whereas automated detection remains challenging due to high spatial similarity across anatomical views with subtle local image appearance variations. To address these challenges, we introduce a very lightweight frequency-guided deep learning-based model named HarmonicEchoNet that can automatically detect heart standard views in a transverse sweep or freehand ultrasound scan of the fetal heart. HarmonicEchoNet uses harmonic convolution blocks (HCBs) and a harmonic spatial and channel squeeze-and-excitation (hscSE) module. The HCBs apply a Discrete Cosine Transform (DCT)-based harmonic decomposition to input features, which are then combined using learned weights. The hscSE module identifies significant regions in the spatial domain to improve feature extraction of the fetal heart anatomical structures, capturing both spatial and channel-wise dependencies in an ultrasound image. The combination of these modules improves model performance relative to recent CNN-based, transformer-based, and CNN+transformer-based image classification models. We use four datasets from two private studies, PULSE (Perception Ultrasound by Learning Sonographic Experience) and CAIFE (Clinical Artificial Intelligence in Fetal Echocardiography), to develop and evaluate HarmonicEchoNet models. Experimental results show that HarmonicEchoNet is 10-15 times faster than ConvNeXt, DeiT, and VOLO, with an inference time of just 3.9 ms. It also achieves 2%-7% accuracy improvement in classifying fetal heart standard planes compared to these baselines. Furthermore, with just 19.9 million parameters compared to ConvNeXt's 196.24 million, HarmonicEchoNet is nearly ten times more parameter-efficient.

19 October 2026 in BMC Pregnancy and Childbirth
Verified
Journal Article
Open access
PDF file
AGAlexander D. Gleed
Alexander D. Gleed
MGMudita Gosain
Mudita Gosain
RTRamachandran Thiruvengadam
Ramachandran Thiruvengadam
SRSaranya Rajaram
Saranya Rajaram
NRNiranjan Rajasekar
Niranjan Rajasekar
JNJ. Alison Noble
J. Alison Noble
Background: In this study, we use quantitative and qualitative assessments to evaluate the feasibility and usability of an obstetric ultrasound video colour overlay to assist placenta localisation and hence risk stratify high-risk pregnancies that have a low-lying placenta. The colour overlay (designed in a previous study) simplifies clinical interpretation of ultrasound video to support screening for pregnant women in rural and low- and middle-income country (LMIC) settings who do not receive care, partly because of a trained operator shortage. Methods: For feasibility, we assessed risk stratification (or checking for a low-lying placenta) of a trained sonographer (6.5 years of experience) using the combined video and colour overlay compared with a hospital freehand scan without a colour overlay. For usability, we recruited 31 Indian healthcare system clinicians in both north and south India hospital sites. We assessed clinical opinions and perceptions of the colour overlay over four study rounds of written questionnaires and a single round of oral interviews. In each round, participants interacted with 20 colour overlays on a portable tablet computer. Results: For feasibility, the sonographer successfully risk stratified the 2 low-lying, high-risk placentas out of a cohort of 55 unique pregnancies (1 video per pregnancy). However, this approach also resulted in 18 false positives (normal placentas that were incorrectly labelled as low-lying). Future feasibility assessment would need to use a larger cohort of pregnancies to strengthen the preliminary findings reported here. For usability, participants gave positive written responses and reported an increase in both confidence when using the colour overlay, and trust in the colour overlay post-study compared to pre-study. From qualitative coding of interview transcripts (1,643 codes and 13 themes generated), the colour overlay was overwhelmingly perceived as an effective risk stratification tool and usable by healthcare workers in rural and LMIC settings. Non-trivial perceived challenges to translation included compliance of the colour overlay with India’s current fetal sex determination law (Pre-Conception and Pre-Natal Diagnostic Techniques Act, 1994), including compliance of targeted users of rural healthcare workers (who cannot currently legally use ultrasound devices), and ultrasound device purchase and maintenance costs. Conclusions: Overall, the colour overlay was perceived favourably by clinicians. For successful adoption of the technology in the Indian healthcare system, the non-technical issues raised would need to be carefully and sensitively addressed.