1 May 2019 in Energy Conversion and Management
16 November 2018 in IEEE Transactions on Power Delivery
In order to predict the changing trend of the dissolved gas in the transformer oil accurately and guide the condition-based maintenance of a power transformer, a combined forecasting model based on cross-entropy is proposed and its application is analyzed. First, a combined forecasting model is established on the basis of radical basis function neural network, back propagation neural network, least squares support vector machine with two different kernel functions, and grey model. Then, the weight coefficient of each algorithm is determined by cross-entropy theory. After that, an application method of the combined forecasting model by the pattern of a variable time window is proposed for the purpose of arranging the equipment maintenance in advance. In this way, the increased budget due to emergency maintenance can be alleviated, and potential loss due to lack of timely maintenance can be reduced. Finally, the accuracy of the combination forecasting method and the effectiveness of the application method are verified by a series of examples.
24 November 2017 in IEEE Transactions on Power Delivery
For lack of the appropriate global distribution of dc currents, the conventional suppression method to suppress dc bias based on capacitive dc blocking device (BD) redirects current to the ground as much as possible, which predisposes to the exceeding neutral current of other transformers in regional power grid and leads to the contradiction between the power grid corporation and other public enterprises. Therefore, this paper presents a flexible suppression method for dc bias based on a novel dc bias suppression device. Firstly, a current balancing device (CBD) based on adjustable parallel resistances is designed. The mathematical model for global optimal switching of CBDs is established by field-circuit coupling method with the equivalent resistance network of ac system along with the location of substations and ground electrodes. The optimal switching scheme to minimize the global maximum dc current is obtained by gravitational search algorithm. Based on the aforementioned work, we propose a suppression strategy considering electro-corrosion of metal pipelines. The effectiveness and superiority of suppression methods are verified by comparative case studies of the Yichang power grid.
1 August 2019 in Applied Energy
4 March 2019 in IEEE Transactions on Power Delivery
For the safety and stability of EHV transmission lines, the identification and isolation of high-resistance single-line-to-ground faults have increasingly been a focus of research. However, the existing protection schemes have shown limitations in different aspects when the fault resistance is extremely high. To solve this problem, an Enhanced Summation Impedance Relay (ESIR) is proposed in this manuscript. An adaptive threshold is set by using the double-end absolute values so that the ESIR can trip the internal fault independent of the data synchronization. Under the open-phase operating conditions, the sound phase ESIR holds sufficient capability against high-resistance faults. Simulation and comparison studies show that the proposed ESIR can work in parallel with several types of existing main protection elements to supplement them to improve high-resistance fault detection. This cooperation enables enhancement of the sensitivity and operating speed of the line protection.