Le Chen

Le Chen

Auto-generated profile, based on publicly available information

Le Chen

State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology, Wuhan, China

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 August 2017 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
LCLe Chen
Le Chen
XLXiangning Lin
Xiangning Lin
ZLZhengtian Li
Zhengtian Li
FWFanrong Wei
Fanrong Wei
Hang ZhaoHang Zhao
Hang Zhao
KDKe Deng
Ke Deng
To solve the following problem: the action speed of protection based on a phasor is restricted by the length of the filtering algorithm time window and the vulnerability to false data, a new pilot protection principle for transmission lines based on waveform similarity is proposed in this paper. By comparing the discrete point sets of current sampling values, a waveform similarity-based algorithm called the Hausdorff distance distinguishes the difference between both side currents of a protected transmission line, realizing fast identification, and removal of the fault. Based on the characteristics of the algorithm, setting methods and protection criterion are discussed. Finally, an improved Hausdorff distance algorithm is proposed to cope with false data. The effectiveness and advantages of the proposed algorithm are validated with theoretical analysis and extensive simulation test results.

5 March 2018 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
FWFanrong Wei
Fanrong Wei
YLYuanzheng Li
Yuanzheng Li
QSQuan Sui
Quan Sui
XLXiangning Lin
Xiangning Lin
LCLe Chen
Le Chen
ZLZhengtian Li
Zhengtian Li
This paper presents a novel phase change material based thermal energy storage system (PCMTESS) that is suitable for smart building energy management, together with its corresponding thermal-electric combined two-stage dispatching strategy. Benefiting from the phase change materials' thermal characteristic of absorbing or releasing a significant amount of heat at a constant temperature, this thermal energy storage system is endowed with a high capacity and a relatively stable thermal state during its charge/discharge process. To evaluate the thermal performance of the PCMTESS, which is integrated as a part of building wallboard, a detailed analytic thermodynamic building model is proposed that considers the influence of the forced air convection and the external environments, such as solar radiation. Furthermore, a two-stage electric-thermal combined dispatching scheme is designed to minimize the electricity consumption expenditure and power fluctuation on the premise of maintaining a comfortable indoor temperature. Simulation studies on a smart building indicate that the proposed thermal energy storage system is a feasible and economical solution for solving peak load shaving and power fluctuation.

8 September 2017 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
LCLe Chen
Le Chen
XLXiangning Lin
Xiangning Lin
ZLZhengtian Li
Zhengtian Li
FWFanrong Wei
Fanrong Wei
NJNeng Jin
Neng Jin
CLChang Liu
Chang Liu
For those protective relays highly dependent on common centralized timing synchronization, the threat of loss of data synchronism, e.g., due to cyber-attack, cannot be ignored. In this case, measurements could be falsely timestamped, leading to undesired mal-operation of protection or evident performance deterioration if countermeasures are lacking. In this paper, several different timing attack scenarios and impacts to protective relays on the transmission line are analyzed. To cope with the timing attack scene, a remedial pilot main protection scheme based only on modulus information of measurements for a transmission line is proposed, independent of timing information. The proposed remedial scheme includes a modulus summation impedance relay, a mid-part relay and an instantaneous over-current relay. The effectiveness of the proposed scheme has been validated by theoretical analysis and simulation tests.

16 November 2018 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
CLChang Liu
Chang Liu
HZHongzhi Zhang
Hongzhi Zhang
ZXZhicheng Xie
Zhicheng Xie
ZWZhixun Wang
Zhixun Wang
LCLe Chen
Le Chen
WXWeihong Xiong
Weihong Xiong
In order to predict the changing trend of the dissolved gas in the transformer oil accurately and guide the condition-based maintenance of a power transformer, a combined forecasting model based on cross-entropy is proposed and its application is analyzed. First, a combined forecasting model is established on the basis of radical basis function neural network, back propagation neural network, least squares support vector machine with two different kernel functions, and grey model. Then, the weight coefficient of each algorithm is determined by cross-entropy theory. After that, an application method of the combined forecasting model by the pattern of a variable time window is proposed for the purpose of arranging the equipment maintenance in advance. In this way, the increased budget due to emergency maintenance can be alleviated, and potential loss due to lack of timely maintenance can be reduced. Finally, the accuracy of the combination forecasting method and the effectiveness of the application method are verified by a series of examples.

30 July 2020 in Biomass Conversion and Biorefinery
Verified
Journal Article
Closed access
PDF file
LCLe Chen
Le Chen
LGLin Guo
Lin Guo
QZQiancong Zhou
Qiancong Zhou
MLMengJie Liu
MengJie Liu
SZSiwei Zhan
Siwei Zhan
YZYongjun Zeng
Yongjun Zeng

16 July 2018 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
NJNeng Jin
Neng Jin
XLXiangning Lin
Xiangning Lin
JXJiawei Xing
Jiawei Xing
ZLZhengtian Li
Zhengtian Li
Shiming LiuShiming Liu
Shiming Liu
NTNing Tong
Ning Tong
As the most suitable main protection for multi-terminal transmission lines represented by T-connections, current differential protection exhibits great performance due to its high reliability and sensitivity. However, considering multiple substations geographically, there are more severe problems of data synchronization for multi-terminal current differential protection than for double-terminal types based on a typical channel. To solve the aforementioned problems, the operating characteristics of multi-terminal line differential protection under different synchronization errors on the - plane are first analyzed. Based on the influence of synchronization errors on the magnitude and phase of the protection operating value, a design method for the restraint current of multi-terminal current differential protection is proposed. To achieve the sensitivity of a high resistance internal fault, as well as the tolerance capability of the data phase-shift error, double restraint coefficients are introduced to optimize the shape and area of the restraint region. Subsequently, the setting method is inferred, which can be used as a reference for an engineering application and the promotion of multi-terminal line differential protection. Finally, the simulation results indicate that the proposed method can significantly improve the criterion security for the case of additional data synchronization errors while maintaining the sensitivity of the internal fault.