In order to investigate the comparability of microsatellite profiles obtained in different laboratories, ten partners in seven countries analyzed 46 grape cultivars at six loci (VVMD5, VVMD7, VVMD27, VVS2, VrZAG62, and VrZAG79). No effort was made to standardize equipment or protocols. Although some partners obtained very similar results, in other cases different absolute allele sizes and, sometimes, different relative allele sizes were obtained. A strategy for data comparison by means of reference to the alleles detected in well-known cultivars was proposed. For each marker, each allele was designated by a code based on the name of the reference cultivar carrying that allele. Thirty-three cultivars, representing from 13 to 23 alleles per marker, were chosen as references. After the raw data obtained by the different partners were coded, more than 97% of the data were in agreement. Minor discrepancies were attributed to errors, suboptimal amplification and visualization, and misscoring of heterozygous versus homozygous allele pairs. We have shown that coded microsatellite data produced in different laboratories with different protocols and conditions can be compared, and that it is suitable for the identification and SSR allele characterization of cultivars. It is proposed that the six markers employed here, already widely used, be adopted as a minimal standard marker set for future grapevine cultivar analyses, and that additional cultivars be characterized by means of the coded reference alleles presented here. The complete database is available at http://www.genres.de/eccdb/vitis/ . Cuttings of the 33 reference cultivars are available on request from the Institut National de la Recherche Agronomique Vassal collection (didier.vares@ensam.inra.fr).
31 March 2000 in Journal of Agricultural and Food Chemistry
Methicillin-Resistant Staphylococcus aureus (MRSA) represents one of the major causes of nosocomial infections, leading to high mortality. Surfaces in clinics, as well as the attending uniform and the hands of the dental doctor can be MRSA reservoirs. Having this in mind, the purpose of this study was to evaluate the presence of Methicillin-Sensitive Staphylococcus aureus (MSSA) and MRSA on dental medicine equipment surfaces. 354 Samples were collected from six equipment surfaces in six attendance areas before and after patient consultation and cultured in a selective medium. Polymerase Chain Reaction (PCR) was used to confirm the identity of bacterial strains as MRSA or MSSA. Data analysis was performed with chi-square tests with Bonferroni correction. It was observed 55.6% of uncontaminated samples. Contamination was: 17.5% MRSA (5.9% of samples collected before patient attendance and 11.6% after); 39.3% MSSA (14.1% collected before and 25.2% after). The prevalence of MRSA and MSSA was significantly higher after patient care. Integrated Clinic represented the most contaminated attendance area (MRSA - 41.7%, MSSA - 51.2%), the chair arm rest was the most contaminated surface for MRSA (29.7%) and the dental spittoon the most contaminated surface for MSSA (23.5%). Although a low level of contamination was observed, dental clinics, through patients possibly carrying bacteria, may be reservoirs for MRSA and MSSA transmission, and might contribute to potential nosocomial infections.