Pavel SkripovPavel Skripov
Pavel Skripov
The investigation is focused on the phenomenon of heat transfer deterioration (HTD), inhibiting the use of supercritical fluids in the processes in which high-power local heat release is possible. The ordinary discussion is based solely on the data of quasi-stationary measurements. In order to clarify the intrinsic nature of HTD as an essentially non-stationary phenomenon, it is worthwhile to take into account the peculiarities of heat transfer confined in time and space. In the present paper, we briefly discuss the characteristic features of such heat transfer in supercritical water. The characteristic heating time was \(10^{-3}\div 10^{-2}\) s and the heat flux density through the wall increased up to 15 MW/m\(^{2}\). The results provide the heat transfer pattern under conditions of predominance of the heat conduction mode. Exactly this mode most closely corresponds to the regime of high-power local heat release in a viscous sublayer. We also propose that the effect of threshold decrease in the heat transfer intensity (typical of pulse processes in supercritical transitions) may be a fundamental factor for occurrence of the HTD mode.

4 May 2012 in Journal of Engineering Thermophysics
Verified
Journal Article
Closed access
PDF file
SRS. B. Rutin
S. B. Rutin
Pavel SkripovPavel Skripov
Pavel Skripov
A technique of electronic control of the probe heating power is developed using the method of controlled pulse heating of a wire probe, that is a resistance thermometer, was developed. An apparatus implementing this technique was fabricated. The characteristic parameters of the apparatus are as follows: the heating pulse length, 1 to 10 ms; the heat flux density through the surface of a 20 µm probe, 1 to 10 MW/m2; repeatability of selected power value in a series of pulses is on a level of 0.05%. As an example, the constant heating power mode is applied for comparing the thermal resistance of nanofluids in the region of stable states of liquid and superheated (with respect to the liquid-vapor equilibrium temperature of the base liquid) ones. The parameter was the content of Al2O3 nanoparticles in the base liquid (isopropanol).

1 December 2021 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
SRS. B. Rutin
S. B. Rutin
The architecture of a novel electronic power regulator, which allows a set value of constant power on a wire probe to be maintained, is presented. A gain in the negative feedback loop of ≈2 · 103 allows the set power value in the series of pulses to be accurately maintained at the level of 99.95% (proximity 0.05). In order to study short term processes, the response time of the described regulator is in the order of 2 μs. The created architecture is easily scalable for various tasks, ranging from the well-known transient hot-wire method to other applications, examples of which are given in this article (unsteady heat transfer in supercritical-pressure fluids and unstable mixtures having lower critical solution temperature). A comparison of the presented controller architecture with the previously described solutions from the point of view of operational stability is given.

1 December 2013 in Russian Journal of Physical Chemistry B
Verified
Journal Article
Closed access
PDF file
SRS. B. Ryutin
S. B. Ryutin
PSP. V. Skripov
P. V. Skripov
A technique based on pulse heating of a wire probe (resistance thermometer) in a constant-heating power regime is developed and used for studies of comparative heat-transfer intensity in supercritical fluids (SCFs) in the pressure and temperature ranges from 1p c to 4–6p c and from 0.6T c to 1.6T c , respectively (p c and T c are critical pressure and temperature). The characteristic parameters of the setup used are as follows: heating -pulse length, 1–10 ms; density of heat flux through the probe surface, 1–10 MW/m2; and repeatability of the selected power value in a series of pulses, not worse than 0.1%. A sharp decrease in the heat-transfer intensity in SCFs compared to that observed at subcritical temperatures is revealed.

14 September 2021 in Instruments and Experimental Techniques
Verified
Journal Article
Closed access
PDF file
SRS. B. Rutin
S. B. Rutin
An apparatus is described for studying unsteady heat transfer in various liquid media by the method of controlled heating of a thin wire probe. The main link of the setup is a high-speed electronic regulator that controls the power dissipated by the probe depending on the control voltage at the regulator input. The main parameters of the apparatus are: the probe is a 1-cm-long 20-μm platinum wire and the controller response time is ≈1–2 μs, the accuracy of maintaining the power value is 0.05%, the heating time is 1–500 ms, and the heat flux density from the probe surface is up to 20 MW/m2. A measurement technique is presented and an example of using a setup for studying the spinodal decomposition of an aqueous solution of polypropylene glycol (PPG-425), which has a lower critical dissolution temperature, is provided.

28 May 2021 in Liquids
Verified
Journal Article
Open access
PDF file
AIAlexander Igolnikov
Alexander Igolnikov
SRSergey Rutin
Sergey Rutin
Pavel SkripovPavel Skripov
Pavel Skripov
In this article, we present a methodology for conducting measurements based on pulse heating of a wire probe in partially soluble binary liquids. These liquids, which can be rapidly transferred to the region of unstable states above the diffusional spinodal, are novel research objects for the thermophysics of extreme states. Using the example of aqueous solutions of polypropylene glycol and glycol monobutyl ether having a lower critical solution temperature, the key hypothesis of the study on the general measurability of the properties of unstable solutions has been confirmed. The characteristic heating times from 1 to 15 milliseconds corresponded to the thickness of the heated layer comprising a few micrometers. The pressure was varied from units of MPa to 100 MPa. The conditions for the transition from measurements on pure components to those on solutions are formulated. The characteristic thermal patterns of the decay of unstable states depending on pressure and heating rate are revealed. The general possibility of using partially soluble binary liquids as a promising coolant in processes involving powerful local heat release is demonstrated.