15 February 2022 in IEEE Transactions on Industrial Electronics
A series-connected 36-pulse rectifier with passive pulse-tripling circuit (PPTC) on the dc side is proposed in this article. The proposed rectifier consists of a series-connected 12-pulse rectifier and a PPTC. The PPTC includes a passive current forming network, a single-phase auxiliary transformer with dual secondary windings and two auxiliary single-phase rectifiers (ASRs). One ASR in PPTC is connected in series with the load to directly modulate the output current of rectifier bridges. The other ASR in PPTC is connected in parallel with the load to modulate the output current of rectifier bridges according to the relationship between its input voltage and load voltage. Composite modulation of the two ASRs increases the pulse number of the rectifier from 12 pulses to 36 pulses. The resulting rectifier obtains an approximate sinusoidal input current with less than 5% THD. Only a few low-capacity passive components are sufficient given the absence of active components in the proposed scheme. The proposed scheme presents advantages of simple circuit structure, easy implementation, and high reliability. Detailed analysis and experimental results are provided to verify the effectiveness of the proposed scheme.
11 October 2023 in IEEE Transactions on Power Electronics
A simple, series-connected, 24-pulse star rectifier employing two different pulse-doubling inter-phase reactors (PD-IPRs) is proposed in this work. The proposed topology consists of two double-star rectifiers, a parallel-connected PD-IPR and a series-connected PD-IPR. The co-modulation of the two PD-IPRs in the rectifier doubles the pulse number of each double-star rectifier and provides a phase displacement of 15° for the two sets of double-star rectifiers. The pulse number of the rectifier is increased from 6 to 24 by the two rectifiers connected in series. The resulting 24-pulse rectifier draws near-sinusoidal input line currents with 4.2% total harmonic distortion. The two small-capacity PD-IPRs can perform phase shifting, thus avoiding the use of complex phase-shifting transformers. The proposed rectifier has a simple structure, easy implementation and low cost. An experimental prototype with an output power of 3.1 kW is constructed to verify the correctness of the theoretical analysis.
4 February 2022 in IEEE Transactions on Industrial Electronics
To effectively suppress the input line current harmonics of 12-pulse rectifier under slightly complex hardware, this letter proposed an input line current step-tripling scheme for 12-pulse rectifier using a novel passive four-tap changer (FTC). The proposed FTC consists of a retrotted four-tap interphase reactor (RFT-IPR) and four auxiliary diodes. Two auxiliary diodes are connected to the inner taps of the RFT-IPR, but the other two auxiliary diodes are connected to the outer taps of the RFT-IPR. The inner and outer auxiliary diodes modulate and increase the output current states of the rectifier bridges together first, then the FTC extends the 12-step to 36-step input line current, and the near sinusoidal input current with 3% THD is obtained. The proposed FTC not only has very low capacity (2.6% of the output power) but also not require any active switching device aside from four auxiliary diodes, thus the proposed scheme is cost-effective, reliable and efficient solution to harmonics pollution. An experimental prototype with output power of 2.4 kW is built, and the correctness of the theoretical analysis is verified by the experimental results.
2 August 2024 in IEEE Transactions on Power Electronics
To solve the problem of the limited harmonic suppression ability of the 12-pulse rectifier, a new pulse-tripling method for the 12-pulse autotransformer rectifier is proposed in this article. The new pulse-tripling method consists of an inter-phase reactor with a secondary side winding, an auxiliary single-phase transformer (AST), and two auxiliary single-phase rectifiers (ASRs). The primary side winding of the AST and the secondary side winding of the interphase reactor are connected in series; by changing the turn ratio of the AST, ASR2 can change the working timing of the auxiliary circuit, thus constituting the three working modes of the rectifier, and the output currents of two sets of three-phase diode bridge rectifiers are modulated into a three-level waveform. Based on the affiliation between the ac and dc sides of the rectifier, the pulse number of the rectifier can be tripled to achieve a new 36-pulse autotransformer rectifier with approximately sinusoidal input current (THD is as low as 2.7%). A 2.4 kW experimental prototype is built to validate the theoretical analysis.
6 September 2024 in IEEE Transactions on Power Electronics
In this paper, a simple series-connected 18-pulse star rectifier is proposed. It consists of a double-star transformer, two sets of three-phase half-wave bridge rectifiers (THBRs), and a pulse-tripling circuit (PTC). The two sets of THBRs adopt the unique connection method of series connection, which provides a midpoint for the PTC. The co-modulation of the four diodes in the PTC makes the rectifier have four working modes and triples the pulse number of the rectifier. Due to the modulation of the PTC, the input current THD of the rectifier is reduced to less than 1/3 of the original. The proposed scheme only needs to add a low rating (10.82% of the output power) PTC on the DC side of the 6-pulse star rectifier, then the new series-connected 18-pulse star rectifier can be obtained. Compared to the conventional 18-pulse rectifiers, the proposed 18-pulse rectifier requires fewer diodes and a simpler phase-shifting transformer. Moreover, in the proposed 18-pulse rectifier, the two sets of THBRs are connected in series, which not only avoids the unbalanced output current problem of THBRs but also provides a new topological choice for series-connected multi-pulse rectifiers. A 1.16 kW experimental prototype was built to verify the correctness of the theoretical analysis.
21 August 2024 in IEEE Journal of Emerging and Selected Topics in Power Electronics
To reduce the volume and weight of the phase-shifting transformer while effectively suppressing the input current harmonics of the 12-pulse rectifier, this paper proposes a 24-pulse rectifier combining a medium-frequency power electronic phase-shifting transformer and a square-wave current injector circuit (SCIC). The proposed 24-pulse rectifier consists of a dual-switch AC/AC converter, a medium-frequency phase-shifting transformer, a three-phase diode rectifier bridge and square-wave current inject circuit (SCIC). The SCIC modulates the output current and voltage of the rectifier bridge by injecting square-wave current. Subsequently, the step number of the input current is increased to 24 based on the relationship between AC and DC currents, which reduces the THD of the input current to half of its original value. The switches in the AC/AC converter operate in a 50% duty cycle medium-frequency state. As a result, the phase-shifting transformer operates at a medium frequency, which effectively reduces the volume and weight of the transformer. Moreover, the SCIC has a low capacity (1.96% P d ) without the need for active device. The circuit has advantages such as simple structure, high reliability, low cost and high reliability. A test prototype with an output power of 1.5 kW was constructed to validate the correctness of the theoretical analysis.