20 January 2021 in IET Renewable Power Generation
Expert, intelligent and robust automatic generation control (AGC) scheme is requisite for stable operation and control of power system (PS) integrated with renewable energy sources (RES) under sudden/random small load disturbances. Large frequency deviations appear if AGC capacity is inept to compensate for the imbalances of generation and demand. In this paper, a cascade‐fractional order ID with filter (C‐I
λ
D
μ
N) controller is proposed as an expert supplementary controller to promote AGC recital adequately in electric power systems incorporated with RES like solar, wind and fuel cells. The imperialist competitive algorithm is fruitfully exploited for optimizing the controller parameters. First, a 2‐area reheat thermal system is examined critically and then to authorize the worth of the proposed controller, the study is protracted to a 2‐area multi‐source hydro‐thermal system. The prominent benefits of C‐I
λ
D
μ
N controller with/without renewable energy sources consist of its great indolence to large load disturbances and superiority over various optimized classical/fuzzy controllers published recently. The sensitivity study validates the robustness of the recommended controller against ±20% deviations in the system parameters and random step load perturbations.
27 December 2020 in International Journal of Energy Research
1 December 2020 in IET Renewable Power Generation
The uncertain demeanour from wind generators and loads adversely affect the grid operational stability. Various control approaches have been explored to remedy the system uncertainties while maintaining generation and load demand balance. This study proposes a fuzzy‐based proportional–fractional integral–derivative with filter controller to sustain frequency stability in wind integrated power systems having different configurations. The controller parameters have been tuned using a recently developed coyote optimisation algorithm (COA). The proposed control approach is executed and validated on three distinct configurations of two‐area power systems. All test models are integrated with a doubly fed induction generator (DFIG) type wind turbine units (WTUs). Different case scenarios have been considered to analyse the efficacy of the proposed control strategy in the presence of WTU. Furthermore, the impact of inertial support delivered by the DFIG‐WTU and higher penetration of wind energy in the power system has been studied. The analysis reveals that the control scheme in coordination with WTU support reduces the stress on a wind turbine during the inertial control scheme and maintains the grid frequency stability under unexpected load disturbances. Stability and robustness analysis are also conducted to verify the validity of the introduced control approach.
7 November 2020 in Electric Power Components and Systems
Regulating the frequency fluctuations (known as load frequency control) in the power system is an important aspect that directly signifies the balance between the generation and demand. The present study proposes an optimal LFC scheme encapsulating the concept of fractional-order based tilted-integral-derivative (TID) controller having optimized parameters using the recently developed optimization technique called salp swarm algorithm. The various non-linearities such as governor dead-band, generation rate constraint, and communication time delays are also considered in the power system having thermal-hydro-wind turbines generating units in both areas. Furthermore, the impact of thyristor controlled phase shifter (TCPS) and redox flow battery (RFB) has been investigated in the proposed power system. Extensive simulations for different test systems and robustness analysis with wide variation in all system parameters at a time have been executed to validate the superiority of the proposed control strategy. The effectiveness of the proposed controller has been studied by comparing system response with recently developed algorithms. The performance evaluations confirm that the proposed controller provides stable, optimal, and superior performance compared to other existing schemes. Further, obtained results strongly suggest that TCPS and RFB units stabilize the transients quickly to enhance the system frequency stability during load instabilities.
2 December 2018 in IETE Journal of Research
Flexible alternating current transmission system devices and energy storage devices have great potential to support frequency regulation in power system. Hence, the impact of interline power flow controller unit and redox flow battery unit in the load frequency control (LFC) of six-area power system having different power plant units has been investigated in this paper. The multi-verse optimizer (MVO) is proposed to tune the parameters of the proportional–integral and derivative (PID) controller. Further, the efficacy of the multi-verse optimizer tuned proportional–integral (PI) controller is also equated with the recently developed sine-cosine algorithm tuned PI controller in the investigated power system. The encouraging role of interline power flow controller (IPFC) unit and redox flow battery (RFB) unit has been confirmed for system frequency and tie-line power regulation. The investigation validated that multi-verse optimizer based proportional–integral–derivative controller with an interline power flow controller unit and redox flow battery unit give better dynamic response during sudden load disturbances.
1 December 2020 in IET Renewable Power Generation
Due to the rapid increase in electrical energy requirements in marine power systems (MPSs), and to reduce the consumption of fossil fuel, there is an emergent need to utilise renewable energy sources (RESs) in MPSs, which has been an attractive field of research. This research aims to present a novel load frequency control (LFC) scheme for a shipboard micro‐grid (SMG) system. Therefore, a MPS with photovoltaic, wind turbine, hybrid energy storage system (ESS), and diesel generator (DG) have been simulated to relate an exact mobile islanded SMG. The system is designed using the transfer function models with the above said generating units and storage systems. Grasshopper optimisation algorithm (GOA) tuned fuzzy‐based proportional–integral–derivative with filter control technique has been proposed to investigate the performance of the LFC scheme for the proposed SMG system. GOA and particle swarm optimisation optimised controllers have been designed and performance evaluation has been carried out on the conventional, adaptive neuro‐fuzzy inference system, and fuzzy cascaded with a conventional controller. The responses obtained from the simulations for different cases are analysed to justify the novelty and superiority of the proposed technique for frequency and power regulation.