Paulo Quintero

Paulo Quintero

Auto-generated profile, based on publicly available information

Paulo Quintero

Memorial Sloan Kettering Cancer Center

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 April 2021 in British Journal of Radiology
Verified
Journal Article
Closed access
PQPaulo Quintero
Paulo Quintero
Yongqiang ChengYongqiang Cheng
Yongqiang Cheng
DBDavid M. Benoit
David M. Benoit
CMCraig Moore
Craig Moore
ABAndrew Beavis
Andrew Beavis
Objective: High levels of beam modulation complexity (MC) and monitor units (MU) can compromise the plan deliverability of intensity-modulated radiotherapy treatments. Our study evaluates the effect of three treatment planning system (TPS) parameters on MC and MU using different multi-leaf collimator (MLC) architectures. Methods: 192 volumetric modulated arc therapy plans were calculated using one virtual prostate phantom considering three main settings: (1) three TPS-parameters (Convergence; Aperture Shape Controller, ASC; and Dose Calculation Resolution, DCR) selected from Eclipse v15.6, (2) four levels of dose-sparing priority for organs at risk (OAR), and (3) two treatment units with same nominal conformity resolution and different MLC architectures (Halcyon-v2 dual-layer MLC, DL-MLC & TrueBeam single-layer MLC, SL-MLC). We use seven complexity metrics to evaluate the MC, including two new metrics for DL-MLC, assessed by their correlation with γ passing rate (GPR) analysis. Results: DL-MLC plans demonstrated lower dose-sparing values than SL-MLC plans (p<0.05). TPS-parameters did not change significantly the complexity metrics for either MLC architectures. However, for SL-MLC, significant variations of MU, target volume dose-homogeneity, and dose spillage were associated with ASC and DCR (p<0.05). MU were found to be correlated (highly or moderately) with all complexity metrics (p<0.05) for both MLC plans. Additionally, our new complexity metrics presented a moderate correlation with GPR (r<0.65). An important correlation was demonstrated between MC (plan deliverability) and dose-sparing priority level for DL-MLC. Conclusions: TPS-parameters selected do not change MC for DL-MLC architecture, but they might have a potential use to control the MU, PTV homogeneity or dose spillage for SL-MLC. Our new DL-MLC complexity metrics presented important information to be considered in future pre-treatment quality assurance programs. Finally, the prominent dependence between plan deliverability and priority applied to OAR dose sparing for DL-MLC needs to be analyzed and considered as an additional predictor of GPRs in further studies. Advances in knowledge: Dose-sparing priority might influence in modulation complexity of DL-MLC.

1 January 2015 in Journal of Contemporary Brachytherapy
Verified
Journal Article
Open access
RCRicardo Cendales
Ricardo Cendales
EAElizabeth Alwers
Elizabeth Alwers
JCJavier Cifuentes
Javier Cifuentes
IBIvan Bobadilla
Ivan Bobadilla
FTFelipe Torres
Felipe Torres
JVJaider Vasquez
Jaider Vasquez
Purpose: High-dose-rate (HDR) brachytherapy has been accepted as an effective and safe method to treat prostate cancer. The aim of this study was to describe acute toxicity following HDR brachytherapy to the prostate, and to examine the association between dosimetric parameters and urinary...

6 December 2022 in Physics in Medicine & Biology
Verified
Journal Article
Open access
PQPaulo Quintero
Paulo Quintero
DBDavid Benoit
David Benoit
YCYongqiang Cheng
Yongqiang Cheng
CMCraig Moore
Craig Moore
ABAndrew Beavis
Andrew Beavis
Machine learning (ML) methods have been implemented in radiotherapy to aid virtual specific-plan verification protocols, predicting gamma passing rates (GPR) based on calculated modulation complexity metrics because of their direct relation to dose deliverability. Nevertheless, these metrics might not comprehensively represent the modulation complexity, and automatically extracted features from alternative predictors associated with modulation complexity are needed. For this reason, three convolutional neural networks (CNN) based models were trained to predict GPR values (regression and classification), using respectively three predictors: (1) the modulation maps (MM) from the multi-leaf collimator, (2) the relative monitor units per control point profile (MUcp), and (3) the composite dose image (CDI) used for portal dosimetry, from 1024 anonymized prostate plans. The models’ performance was assessed for classification and regression by the area under the receiver operator characteristic curve (AUC_ROC) and Spearman’s correlation coefficient ( r ). Finally, four hybrid models were designed using all possible combinations of the three predictors. The prediction performance for the CNN-models using single predictors (MM, MUcp, and CDI) were AUC_ROC = 0.84 ± 0.03, 0.77 ± 0.07, 0.75 ± 0.04, and r = 0.6, 0.5, 0.7. Contrastingly, the hybrid models (MM + MUcp, MM + CDI, MUcp+CDI, MM + MUcp+CDI) performance were AUC_ROC = 0.94 ± 0.03, 0.85 ± 0.06, 0.89 ± 0.06, 0.91 ± 0.03, and r = 0.7, 0.5, 0.6, 0.7. The MP, MUcp, and CDI are suitable predictors for dose deliverability models implementing ML methods. Additionally, hybrid models are susceptible to improving their prediction performance, including two or more input predictors.

10 March 2025 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PQPaulo Quintero
Paulo Quintero
CWCan Wu
Can Wu
HZHao Zhang
Hao Zhang
RORicardo Otazo
Ricardo Otazo
LCLaura Cervino
Laura Cervino
WHWendy Harris
Wendy Harris
Introduction. Real-time 2D-kV-triggered images used to evaluate intra-fraction motion during abdominal radiotherapy only provides 2D information with poor soft-tissue contrast. The main goal of this research is to evaluate a novel method that generates synthetic 3D-MRI from single 2D-kV images for online motion monitoring in abdominal radiotherapy. Methods. Deformable image registration (DIR) is performed between one 4D-MRI reference phase and all other phases, and principal-component-analysis (PCA) is implemented on their respective deformation vectors. By sampling 1,000 times the PCA eigenvalues and applying the new deformations over a reference CT, 1,000 digital reconstructed radiographs (DRRs) were generated to train a convolutional neural network (CNN) to predict their respective eigenvalues. The method was implemented and tested using a digital phantom (XCAT) and an MRI-compatible phantom (ZEUS) with five DRR angles (0°, 45°, 90°, 135°, 180°). Seven motion scenarios were tested. For model performance, mean absolute error (MAE) and root mean square error (RMSE) were reported. Image quality was evaluated with structure similarity index (SSIM) and normalized RMSE (nRMSE), and target-volume variations were evaluated with volumetric dice coefficient (VDC) and Hausdorff-distance (HD). Results. The model performance across the evaluated angles were MAE(XCAT, ZEUS)=(0.053±0.003, 0.094±0.003), and RMSE(XCAT, ZEUS)=(0.054±0.007, 0.103±0.002). Similarly, SSIM(XCAT, ZEUS)=(0.994±0.001, 0.96±0.02), and nRMSE(XCAT, ZEUS)=(0.13±0.01, 0.17±0.03). For all motion scenarios for XCAT and ZEUS, SSIM were 0.98±0.01 and 0.84±0.02, nRMSE were 0.14±0.01 and 0.27±0.02, VDC were 0.98±0.01 and 0.90±0.01, and HD were 0.24±0.02 mm and 2.3±0.8 mm, respectively, averaged across all angles. Finally, SSIM, nRMSE, VDC and HU values for ZEUS using the deformed images as ground truth, presented an improvement of 13%, 28%, 4%, and 76%, respectively. Conclusion. Results from a digital and physical phantom demonstrate a novel approach to generate real-time 3D synthetic MRI from onboard kV images on a conventional LINAC for intra-fraction monitoring in abdominal radiotherapy.

2 May 2023 in British Journal of Radiology
Verified
Journal Article
Closed access
PQPaulo Quintero
Paulo Quintero
DBDavid Benoit
David Benoit
YCYongqiang Cheng
Yongqiang Cheng
CMCraig Moore
Craig Moore
ABAndrew Beavis
Andrew Beavis
Objective: Gamma passing rate (GPR) predictions using machine learning methods have been explored for treatment verification of radiotherapy plans. However, these methods presented datasets with unbalanced number of plans having different treatment conditions (heterogeneous datasets), such as anatomical sites or dose per fractions, leading to lower model interpretability and prediction performance. Methods: We investigated the impact of the dataset composition on GPR binary classification (pass/fail) using random forest (RF), XG-boost, and neural network (NN) models. 945 plans were used to create one reference dataset (randomly assembled) and 24 customized datasets that considered four heterogeneity factors independently (anatomical region, number of arcs, dose per fraction, and treatment unit). 309 predictor features were extracted and calculated from plan parameters, modulation complexity metrics, and radiomic analysis (leave-trajectory maps, 3D dose distributions, and portal dosimetry images). The models’ performances were measured using the area under the curve from the receiver operating characteristic (ROC-AUC). Results: Radiomics features for reference models increased ROC-AUC values up to 13%, 15%, and 5% for RF, XG-Boost, and NN, respectively. The datasets with higher heterogeneous conditions presented the lower ROC-AUC values (RF: 0.72 ± 0.11, XG-Boost: 0.67 ± 0.1, NN: 0.89 ± 0.05) compared to models with less heterogeneous treatment conditions (RF: 0.88 ± 0.06, XG-Boost: 0.89 ± 0.07, NN: 0.98 ± 0.01). The ten most important features for each heterogeneity dataset group demonstrated their correlation with the treatments’ physical aspects and GPR prediction. Conclusion: Improvements in data generalization and model performances can be associated with datasets having similar treatment conditions. This analysis might be implemented to evaluate the dataset quality and model consistency of further ML applications in radiotherapy. Advances in knowledge: Dataset heterogeneities decrease ML model performance and reliability.

5 June 2026 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PQPaulo Quintero
Paulo Quintero
VYVictoria Yu
Victoria Yu
CWCan Wu
Can Wu
LSLauren Smith
Lauren Smith
RORicardo Otazo
Ricardo Otazo
WHWendy Harris
Wendy Harris
Introduction: This study aims to generate synthetic-MRI(synMRI) for abdominal patients undergoing radiotherapy using Deep Inspiration Breath Hold(DIBH) on a conventional Linac. Methods: XCAT phantom and patient data were used to develop and test a patient-specific model to generate synMRI. During patient simulation, 6 DIBH-MRIs and 1 DIBH-CT were acquired. One DIBH-MRI was set as the reference MRI(refMRI) and Principal Component Analysis(PCA) was performed using five Deformation Field Maps(DFMs) by applying deformable image registration between refMRI and the other DIBH-MRIs. PCA eigenvalues were sampled 1,000 times to generate new deformations applied to a synthetic-CT with the same anatomic conditions as refMRI. A convolutional neural network was trained to predict the eigenvalues corresponding to on-board conditions from a CBCT to generate a final synMRI with the new DFM. Four XCAT scenarios simulated changes from simulation to treatment. The model was evaluated using mean-absolute-error(MAE) and root-mean-square-error(RMSE), and the image quality was evaluated by structure-similarity-index metric(SSIM) and normalized RMSE(nRMSE). The accuracy of the predicted target volume for XCAT and fiducial clips for each patient was analyzed using center-of-mass-shift(COMS) between on-board conditions (ground-truth synMRI for XCAT and CBCT for patients) and the predicted synMRI. The liver dome difference was also evaluated. Results: Model performance yielded an MAE of 0.11±0.02 for XCAT, and 0.15±0.01, 0.15±0.02, 0.10±0.03, 0.12±0.09 for four patients, respectively. RMSE values were 0.11±0.07, 0.16±0.03, 0.19±0.01, 0.13±0.07, and 0.14±0.04. For image quality, SSIM values were 0.999±0.001 for XCAT, and 0.998±0.001, 0.995±0.002, 0.996±0.001, 0.998±0.001 for the patients. The nRMSE were 0.10±0.06, 0.58±0.03, 0.87±0.06, 0.39±0.04, and 0.35±0.02, respectively. For XCAT, the liver dome difference and tumor COMS were <0.5 mm in all scenarios. For all patients, liver dome differences were <1 mm, and fiducial COMSs were <1.2 mm. Conclusions: The novel method generates synMRI using on-board conditions in DIBH abdominal treatments performed on a conventional LINAC.