A 1.2-Mpixel indirect time-of-flight (ToF) CMOS image sensor is presented to lower peak current and to cancel out multi-user interference. The proposed 4-tap 3.5-μm demodulation pixel is optimally designed to improve quantum efficiency (QE) and demodulation contrast (DC). A new ``multiple-interleaving'' scheme is proposed to reduce the peak current and self-compensate fixed-pattern phase noise (FPPN) with the minimal side effect of DC imbalance. To cancel out interference from the other ToF sensors, a multi-user interference cancellation (MUIC) scheme based on pseudorandom modulation is adopted. From the measurement results, we achieve a high QE of 38% at 940 nm and a high DC of 96% and 80% at 100- and 200-MHz modulation frequencies, respectively. With the superior pixel performance, the depth noise of <0.92% and <0.3% is achieved at the full and 2 x 2 binning modes, respectively. The multiple-interleaving scheme suppresses the peak current to less than 0.9 A and removes the column FPPN with constant DC for the whole pixel array. The proposed MUIC proves that at least two interferers can be successfully rejected. The sensor chip is fabricated in a two-stack process with 65 nm for the top die and 65 nm for the bottom die.
29 February 2008 in Oral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology
We propose a surveillance system with fiber optic cables based on multi-channel distributed acoustic sensing (DAS) interrogator equipped with optical rotary switch. By switching the optical connection between the interrogator and multiple optical fiber-under-test, we can sample the sensed vibration signal from the fibers with single pulse generator and optical receiver. To identify the source of detected vibration signal, we separated the monitoring process as 2-phases. In the phase-1, we monitor the fibers during 3 second periodically and simply classify the vibration signal is whether threat or non-threat to the fiber-optic cable route using 1-dimensional convolutional neural network. When the result is threat, the optical switch fixed the port and we intentionally monitor the fiber in 10 second to acquire more vibration signal. We adopted 2-D convolutional neural network to classify the source of vibration signal. We trained the two classification models with vibration signal from the deployed fiber-optic cables and the results show the accuracy of 94.5 and 98.2 %.
We propose an injection locked triple contact Fabry-Pérot laser diode (TC F-P LD) for an uncooled WDM systems. By controlling injection currents to three electrodes of the TC F-P LD, we are able to tune the cavity mode for an optimum injection locking without using temperature control. Then, we transmitted 20 Gb/s/channel QPSK signal using the LD as either an optical carrier or a local oscillator. We identified contributions of the performance degradation as a) intensity noise resulting from a finite common mode rejection ratio associated with a relative intensity noise and b) decrease of the effective LO power for coherent detection. Finally, we show the uniform BER performance with change of the injection wavelength by 2.8 nm. This is corresponding to 28 C° change of operating temperature.
The purpose of this study was to evaluate the effect of defect type and depth as well as measurement direction on implant stability in an ex vivo peri-implant bovine rib bone model. Six kinds of defects (3-wall 2.5 mm, 3-wall 5 mm, 1-wall 2.5 mm, 1-wall 5 mm, circumferential 2.5 mm, circumferential 5 mm) and control (no defect) were prepared in 14 bovine rib bones. A total of 84 defects and 14 controls were created. The same type and size of implants (4x10 mm) were placed in each group. The thickness of cortical bone and the insertion torque were measured for each defect and the ISQ value was measured three times from four different directions. The thickness of cortical bone ranged from 2.71 to 3.18 mm. Insertion torque decreased as the defect size increased. As the defect size for the same defect depth increased, the ISQ value decreased (p<0.001). There were significant differences between the ISQ values obtained with different measurement directions only between the control and 3-wall 5 mm defect (p<0.0001). The ISQ value opposite to the defect direction was higher than that in the defect direction in all three directions of the 3-wall and 1-wall 5 mm defects. ISQ values were influenced by defect type and depth. Loss of cortical bone reduced the stability of implants and reduced the ISQ value. Measurement direction also influenced ISQ values.