Libby A. Mauter

Libby A. Mauter

Auto-generated profile, based on publicly available information

Libby A. Mauter

Western Orthopaedics, Denver, Colorado

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 November 2025 in Journal of Bone and Joint Surgery
Verified
Journal Article
Open access
BGB. Gage Griswold
B. Gage Griswold
JBJean Marie Berger
Jean Marie Berger
BDBrian P. Davis
Brian P. Davis
LMLibby Mauter
Libby Mauter
MBMallory Boyd
Mallory Boyd
AHArmodios M. Hatzidakis
Armodios M. Hatzidakis
Background: This study evaluated the progression of humeral head medialization in patients who underwent pyrocarbon hemiarthroplasty (PyC-HA). The authors hypothesized that glenoid erosion would not dramatically progress between the short-term and final imaging evaluations, and that there would be excellent clinical outcomes at ≥5-year follow-up. Methods: Patients who underwent PyC-HA with ≥60 months of follow-up were included in this prospective study. Relevant data included preoperative demographic characteristics, Walch glenoid classification, changes in clinical outcomes, and revision-free and failure-free survival rates. An investigator, who was blinded to patient outcomes, assessed the glenoid morphology, changes in medialization, joint space, acromiohumeral distance (AHD), critical shoulder and β angles, and posterior subluxation in decentered glenoids at the 2-year and final follow-up visits. Results: Forty-five patients with a mean age of 52 years and a mean follow-up of 73 months met the inclusion criteria. Significant improvements were observed across all outcome measures. The 7-year revision-free survival rate was 95.7%. Posterior subluxation in decentered shoulders decreased from 27.1% preoperatively to 19.8% postoperatively (p = 0.008). The mean medialization of the humeral head was 2.9 ± 2.8 mm at the 2-year follow-up and increased to 4.0 ± 3.3 mm at the time of the final follow-up (p = 0.096). A >2-mm decrease in AHD from early postoperative to final imaging was observed in 82.2% of patients (p < 0.001). All other radiographic changes were not significant. Conclusions: PyC-HA is a reliable procedure for treating glenohumeral joint disease, demonstrating excellent clinical outcomes and stabilized glenoid morphology in the majority of patients between the 2-year and intermediate-term follow-up. Level of Evidence: Therapeutic Level II . See Instructions for Authors for a complete description of levels of evidence.

29 December 2025 in Journal of Bone and Joint Surgery
Verified
Journal Article
Closed access
AHArmodios M. Hatzidakis
Armodios M. Hatzidakis
GGGrant E. Garrigues
Grant E. Garrigues
LMLibby A. Mauter
Libby A. Mauter
AGArthur de Gast
Arthur de Gast
MVMatthew R. Venegoni
Matthew R. Venegoni
PJPeter S. Johnston
Peter S. Johnston
Background: Unacceptable pain relief after hemiarthroplasty (HA) has limited its utilization for shoulder replacement. The material properties of pyrolytic carbon-graphite composites may result in less abrasion compared with metal bearing surfaces, theoretically decreasing glenoid-sided pain and erosion. This prospective, single-arm, multicenter study was performed to evaluate the short-term clinical outcomes and implant survivorship of pyrocarbon HA. Methods: The enrollment of 157 patients occurred at 18 sites between December 2015 and April 2017 as part of an Investigational Device Exemption protocol. The Constant score, American Shoulder and Elbow Surgeons (ASES) score, Single Assessment Numeric Evaluation (SANE) score, patient satisfaction, EuroQol-5 Dimensions (EQ-5D) score, and active range of motion were evaluated. A historical control cohort treated with cobalt-chromium HA was identified through a propensity score subclassification analysis. The pyrocarbon HA and cobalt-chromium HA cohorts were compared on the basis of a Composite Clinical Success (CCS) rate, defined as a ≥17-point change in the Constant score without revision or a device-related adverse event. Results: Of the 157 patients enrolled, 144 had short-term follow-up (mean, 24.4 ± 1.2 months), 10 were lost to follow-up, and 3 underwent revision prior to 24 months due to pain or low-grade infection. The mean patient age was 52.4 ± 10.9 years (range, 19 to 73 years). There were significant improvements in all active range-of-motion and patient-reported outcomes. The outcomes of the pyrocarbon HA cohort (n = 157) were compared with those of the cobalt-chromium HA group (n = 169) eligible for a minimum 24-month follow-up, in which multiple imputation was employed to address missing data. The CCS was 82.7% for the pyrocarbon HA group and 66.8% for the cobalt-chromium HA group (p < 0.001). Conclusions: Pyrocarbon HA demonstrated favorable results at a short-term follow-up and improved outcomes compared with the propensity score subclassification-derived cobalt-chromium HA cohort. Level of Evidence: Therapeutic Level III . See Instructions for Authors for a complete description of levels of evidence.

28 November 2018 in JBJS Case Connector
Verified
Journal Article
Closed access
RGRyan M. Greene
Ryan M. Greene
JBJacqueline E. Bader
Jacqueline E. Bader
LMLibby Mauter
Libby Mauter
BSBenjamin Sears
Benjamin Sears
CTConrad J. Tirre
Conrad J. Tirre
AHArmodios M. Hatzidakis
Armodios M. Hatzidakis
Case: A 49-year-old right-hand-dominant man sustained an auger-related injury that resulted in open dislocation at the left wrist and palm, with complete amputation of the distal aspect of the forearm and the hand. The injury at the elbow included instability with an ulnar coronoid fracture, posterior dislocation of the ulna, and posterolateral dislocation of the radius. To restore stability of the forearm stump and elbow, we performed a complete resection of the radius, open reduction and internal fixation of the coronoid tip, a repair of the lateral collateral ligament, and transfer of the distal biceps tendon to the coronoid. Conclusion: The procedure stabilized the elbow, allowing for early mobilization. The patient was eventually fitted with a prosthesis that allowed him to return to full-time manual labor in a rural setting.

1 July 2024 in JBJS Essential Surgical Techniques
Verified
Journal Article
Closed access
BDBrian P. Davis
Brian P. Davis
LMLibby A. Mauter
Libby A. Mauter
BSBenjamin Sears
Benjamin Sears
AHArmodios M. Hatzidakis
Armodios M. Hatzidakis
Background: Intramedullary straight nail fixation of proximal humeral fractures using a locking mechanism provides advantages compared with plating, including (1) less soft-tissue dissection, which preserves periosteal blood supply and soft-tissue attachments; (2) improved construct stability for comminuted fractures or osteopenic bone; and (3) shorter operative time for simpler fractures. Description: The patient is placed in the beach-chair position with the head of the bed elevated approximately 45°. The fracture is reduced with use of closed or percutaneous methods, ideally, or with an open approach if required. Temporary fragment fixation with percutaneous Kirschner wires can be utilized. A 1-cm incision is made just anterior to the acromioclavicular joint, overlying the zenith of the humeral head and in line with the diaphysis. A guide-pin is then placed through this incision and is verified to be centrally located and in line with the humeral diaphysis on fluoroscopic views. The guide-pin is advanced into the diaphysis. A cannulated 9-mm reamer is inserted over the guide-pin to create a starting position. The nail is then inserted, with adequate fragment reduction maintained until the proximal nail portion is buried under the subchondral humeral head. The proximal screw trajectory and alignment are checked fluoroscopically. The proximal locking screws are pre-drilled and inserted first using percutaneous drill sleeves through the radiolucent targeting jig. The screw is inserted through the guide and is advanced into the nail until appropriately seated. This process is then repeated for the other proximal screws as necessary. Finally, the distal diaphyseal screws are pre-drilled and inserted in a similar percutaneous fashion using the jig, and the jig is removed. Final orthogonal images are obtained. Copious irrigation of the incisions is performed and they are closed and dressed with a sterile dressing. The operative arm is placed in an abduction sling. Alternatives: Alternative treatment options for proximal humeral fractures include nonoperative treatment with use of a sling, percutaneous reduction and internal fixation with Kirschner wires, open reduction and internal fixation with a locking plate and screw construct, hemiarthroplasty, and anatomic or reverse total shoulder arthroplasty 1 . Rationale: The presently described technique for proximal humeral fracture fixation using a straight, antegrade, locking nail allows for minimal soft-tissue disruption, preserving vascularity and soft-tissue support and achieving angularly stable fixation in often osteopenic bone. The superior and in-line entry point avoids complications of rotator cuff injury and/or subacromial impingement. The proximal locking screws avoid complications of screw penetration or migration. This technique is appropriate for surgically indicated Neer 2-, 3-, and 4-part humeral fractures, including in elderly patients, when the humeral head fragment remains viable 1–5 . Expected Outcomes: Based on available Level-III and IV evidence using this technique, patients should expect recovered motion and the ability to perform daily activities independently, with a mean active elevation of 132° to 136° 1,4,6 , external rotation of 37° to 52° 1,4,6 , and internal rotation to L3 1 . Pain scores improved significantly from preoperatively to postoperatively, with a mean pain score of 1.4 on the visual analogue scale 3,4,6 . Patient-reported outcomes were good to excellent, with Single Assessment Numerical Evaluation (SANE) scores of 80% to 81% 1,6 , mean Constant scores from 71 to 81 1,3,4,6 , and high rates of patient satisfaction (97% satisfied or very satisfied) 4 . Studies also demonstrated good to excellent fracture healing, with no tuberosity migration and low rates of nonunion (0% to 5%) 1,6 and humeral head necrosis (0% to 4%) 1,4 . Revision rates ranged from 10.5% to 16.7% 4,6 . Important Tips: The starting position of the guide-pin must be central and at the zenith of the humeral head on the anteroposterior Grashey and the scapular Y views, and the guide-pin must be aligned with the diaphysis prior to advancing it. Failure to bluntly dissect the percutaneous incisions risks injury to the axillary nerve. Verify correct version of the nail prior to drilling any screws, to avoid incorrect version and potential loss of functional rotation. Acronyms and Abbreviations: ABD = abduction AP = anteroposterior CT = computed tomography ER = external rotation FF = forward flexion (forward elevation) IR = internal rotation SANE = Single Assessment Numerical Evaluation SSV = Subjective Shoulder Value VAS = Visual Analogue Scale

4 June 2025 in Seminars in Arthroplasty: JSES
Verified
Journal Article
Closed access
BGB. Gage Griswold
B. Gage Griswold
BDBrian P. Davis
Brian P. Davis
HSHayden B. Schuette
Hayden B. Schuette
BSBenjamin Sears
Benjamin Sears
ASAndrea Stapleford
Andrea Stapleford
AHArmodios M. Hatzidakis
Armodios M. Hatzidakis

3 December 2025 in Journal of the American Academy of Orthopaedic Surgeons
Verified
Journal Article
Closed access
RCRose G. Christensen
Rose G. Christensen
BGBranum G. Griswold
Branum G. Griswold
BSBenjamin W. Sears
Benjamin W. Sears
JKJames D. Kelly
James D. Kelly
MKMichael S. Khazzam
Michael S. Khazzam
AHArmodios M. Hatzidakis
Armodios M. Hatzidakis
Background: Partially cemented all-polyethylene glenoids with press-fit fluted central peg (FCP) fixation are commonly used for anatomic total shoulder arthroplasty (aTSA). The purpose of this study was to evaluate clinical outcomes and radiographic findings in patients with ≥48-month follow-up after aTSA with one FCP glenoid design. Methods: A prospective patient registry was used to identify a consecutive group of patients who had undergone aTSA using a FCP glenoid and had ≥48-month follow-up. Final postoperative radiographs, as well as short-term if available, were assessed by five shoulder specialists for bony incorporation and/or radiolucency about the FCP using a validated discriminatory method of evaluating native glenoid reaction to the FCP. Changes in patient-reported and clinical outcomes were evaluated, and regression analysis was performed to identify predictors of central peg osteolysis (CPO), poor clinical outcome, or revision. Results: Eighty-three shoulders satisfied inclusion criteria. At final follow-up (average 90 months), notable improvements were noted in all outcomes ( P < 0.05), including a 75% satisfaction rate. On final imaging, 16 patients (19%) demonstrated optimal FCP bony ingrowth, and 23 (28%) demonstrated CPO. The radiographic appearance of bone around the central peg tended to deteriorate over time and trended with worsened clinical outcomes, but these differences were not notable. Of 73 patients with short-term and final imaging, progression of radiolucency was observed in 30 (41%) and associated with less improvement in American Shoulder and Elbow Surgeons score ( P = 0.026) and Single Assessment Numeric Evaluation ( P = 0.022) scores. Risk of revision was 13% greater in patients with CPO on final imaging while increased age was associated a lower risk of revision. Conclusion: Clinical improvement was observed in most of the patients, but with a dissatisfaction rate of 25%. Progression of CPO was associated with lower improvement in final American Shoulder and Elbow Surgeons score and Single Assessment Numeric Evaluation scores and a higher probability of revision. Level of Evidence: Level IV Case Series.