Arthur de Gast

Arthur de Gast

Auto-generated profile, based on publicly available information

Arthur de Gast

Trauma & Extremities, Upper Extremities and Medical Affairs

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2022 in JBJS Reviews
Verified
Journal Article
Closed access
BGB.A.T.D. van der Gronde
B.A.T.D. van der Gronde
TSTom Schlösser
Tom Schlösser
JEJ.H.J. van Erp
J.H.J. van Erp
TST.E. Snijders
T.E. Snijders
René M. CasteleinRené M. Castelein
René M. Castelein
AGA. de Gast
A. de Gast
Background: Decreased pelvic mobility and pelvic retroversion may result from spinal degeneration and lead to changes in the orientation of the acetabular implant after total hip arthroplasty (THA). While multiple patient and surgery-related factors contribute to THA dislocations, there is increasing evidence that sagittal spinopelvic dynamics are relevant for THA stability. The aim of this systematic review was to assess the relationship between previously described sagittal spinopelvic characteristics and implant dislocations after primary THA. Methods: A comprehensive literature search in the PubMed and Embase databases was conducted for studies reporting on spinopelvic morphology, alignment, pathology, or surgery and THA dislocations. Risk of bias was assessed using the MINORS criteria. Because of high heterogeneity in study methodology, a synthesis of best evidence was performed. Odds ratios (ORs), relative risks (RRs), and effect sizes (g) were calculated. Results: Fifteen studies (1,007,900 THAs) with quality scores of 15 to 23 out of 24 were included. Nine different spinopelvic alignment parameters (8 studies, g = 0.14 to 2.02), spinal pathology (2 studies, OR = 1.9 to 29.2), and previous spinal fusion surgery (8 studies, OR = 1.59 to 23.7, RR = 3.0) were found to be related to THA dislocation. Conflicting results were found for another sagittal pelvic morphology parameter, pelvic incidence. Conclusions: Several sagittal spinopelvic patient characteristics were found to be related to THA dislocation, and the associated risks were greater than for other patient and surgery-related factors. Future research is needed to determine which of those characteristics and parameters should be taken into account in patients undergoing primary THA. Level of Evidence: Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.

3 February 2021 in Archives of orthopaedic and trauma surgery
Verified
Journal Article
Open access
PDF file
JEJ. H. J. van Erp
J. H. J. van Erp
JMJ. R. A. Massier
J. R. A. Massier
STSteven Truijen
Steven Truijen
JBJ. E. J. Bekkers
J. E. J. Bekkers
TST. E. Snijders
T. E. Snijders
AGA. de Gast
A. de Gast
Purpose: Total hip arthroplasty (THA) is a successful procedure. However, in time, heterotopic ossification (HO) can form due to, amongst others, soft tissue damage. This can lead to pain and impairment. This study compares the formations of HO between patients who underwent either THA with the posterolateral approach (PA) or with the direct lateral approach (DLA). Our hypothesis is that patients who underwent THA with a PA form less HO compared to THA patients who underwent DLA. Methods: In this prospective cohort study, 296 consecutive patients were included who underwent THA. A total of 127 patients underwent THA with the PA and 169 with the DLA. This was dependent on the surgeon’s preference and experience. More than 95% of patients had primary osteoarthritis as the primary diagnosis. Clinical outcomes were scored using the Numeric Rating Scale (NRS) and Harris Hip Score (HHS), radiological HO were scored using the Brooker classification. Follow-up was performed at 1 and 6 years postoperatively. Results: Two hundred and fifty-eight patients (87%) completed the 6-year follow-up. HO formation occurred more in patients who underwent DLA, compared to PA (43(30%) vs. 21(18%), p = 0.024) after 6 years. However, the presence of severe HO (Brooker 3–4) was equal between the DLA and PA (7 vs. 5,p = 0.551). After 6 years the HHS and NRS for patient satisfaction were statistically significant higher after the PA (95.2 and 8.9, respectively) compared to the DLA (91.6 and 8.5, respectively) (p < 0.001 and p = 0.003, respectively). The NRS for load pain was statistically significant lower in the PA group (0.5) compared to the DLA group (1.2) (p = 0.004). The NRS for rest pain was equal: 0.3 in the PA group and 0.5 in the DLA group. Conclusion: THA with the PA causes less HO formation than the DLA. Trial registration: Registrated as HipVit trial, NL 32832.100.10, R-10.17D/HIPVIT 1. Central Commission Human-Related research (CCMO) Registry.

12 July 2018 in JBJS Open Access
Verified
Journal Article
Open access
TST.E. Snijders
T.E. Snijders
TSTom Schlösser
Tom Schlösser
SGS.M. van Gaalen
S.M. van Gaalen
René M. CasteleinRené M. Castelein
René M. Castelein
Harrie WeinansHarrie Weinans
Harrie Weinans
AGA. de Gast
A. de Gast
Background: Acetabular cup orientation plays a key role in implant stability and the success of total hip arthroplasty. To date, the orientation has been measured with different imaging modalities and definitions, leading to lack of consensus on optimal cup placement. A 3-dimensional (3D) concept involving a trigonometric description enables unambiguous definitions. Our objective was to test the validity and reliability of a 3D trigonometric description of cup orientation. Methods: Computed tomographic scans of the pelvis, performed for vascular assessment of 20 patients with 22 primary total hip replacements in situ, were systematically collected. On multiplanar reconstructions, 3 observers independently measured cup orientation retrospectively in terms of coronal inclination, sagittal tilt, and transverse version. The angles measured in 2 planes were used to calculate the angle in the third plane via a trigonometric algorithm. For correlation and reliability analyses, intraobserver and interobserver differences between measured and calculated angles were evaluated with use of the intraclass correlation coefficient (ICC). Results: Measured and calculated angles had ICCs of 0.953 for coronal inclination, 0.985 for sagittal tilt, and 0.982 for transverse version. Intraobserver and interobserver reliability had ICCs of 0.987 and 0.987, respectively, for coronal inclination; 0.979 and 0.981, respectively, for sagittal tilt; and 0.992 and 0.978, respectively, for transverse version. Conclusions: The 3D concept with its trigonometric algorithm is a valid and reliable tool for the measurement of cup orientation. Clinical Relevance: By calculating the transverse version of cups from coronal inclination and sagittal tilt measurements, the trigonometric algorithm enables a 3D definition of cup orientation, regardless of the imaging modality used. In addition, it introduces sagittal tilt that, like pelvic tilt, rotates around the transverse axis.

29 December 2025 in Journal of Bone and Joint Surgery
Verified
Journal Article
Closed access
AHArmodios M. Hatzidakis
Armodios M. Hatzidakis
GGGrant E. Garrigues
Grant E. Garrigues
LMLibby A. Mauter
Libby A. Mauter
AGArthur de Gast
Arthur de Gast
MVMatthew R. Venegoni
Matthew R. Venegoni
PJPeter S. Johnston
Peter S. Johnston
Background: Unacceptable pain relief after hemiarthroplasty (HA) has limited its utilization for shoulder replacement. The material properties of pyrolytic carbon-graphite composites may result in less abrasion compared with metal bearing surfaces, theoretically decreasing glenoid-sided pain and erosion. This prospective, single-arm, multicenter study was performed to evaluate the short-term clinical outcomes and implant survivorship of pyrocarbon HA. Methods: The enrollment of 157 patients occurred at 18 sites between December 2015 and April 2017 as part of an Investigational Device Exemption protocol. The Constant score, American Shoulder and Elbow Surgeons (ASES) score, Single Assessment Numeric Evaluation (SANE) score, patient satisfaction, EuroQol-5 Dimensions (EQ-5D) score, and active range of motion were evaluated. A historical control cohort treated with cobalt-chromium HA was identified through a propensity score subclassification analysis. The pyrocarbon HA and cobalt-chromium HA cohorts were compared on the basis of a Composite Clinical Success (CCS) rate, defined as a ≥17-point change in the Constant score without revision or a device-related adverse event. Results: Of the 157 patients enrolled, 144 had short-term follow-up (mean, 24.4 ± 1.2 months), 10 were lost to follow-up, and 3 underwent revision prior to 24 months due to pain or low-grade infection. The mean patient age was 52.4 ± 10.9 years (range, 19 to 73 years). There were significant improvements in all active range-of-motion and patient-reported outcomes. The outcomes of the pyrocarbon HA cohort (n = 157) were compared with those of the cobalt-chromium HA group (n = 169) eligible for a minimum 24-month follow-up, in which multiple imputation was employed to address missing data. The CCS was 82.7% for the pyrocarbon HA group and 66.8% for the cobalt-chromium HA group (p < 0.001). Conclusions: Pyrocarbon HA demonstrated favorable results at a short-term follow-up and improved outcomes compared with the propensity score subclassification-derived cobalt-chromium HA cohort. Level of Evidence: Therapeutic Level III . See Instructions for Authors for a complete description of levels of evidence.

1 April 2013 in Transfusion and Apheresis Science
Verified
Journal Article
Closed access
RER. Eshuis
R. Eshuis
PBP.J. Borgdorff
P.J. Borgdorff
WKW. Kortlandt
W. Kortlandt
JHJ.J. Halma
J.J. Halma
AGA. de Gast
A. de Gast

11 February 2026 in Digital Health
Verified
Journal Article
Open access
PMPierre Mahe
Pierre Mahe
SSSarah Shank
Sarah Shank
AGArthur de Gast
Arthur de Gast
MRMaud Reynier
Maud Reynier
Background: Software-based preoperative 3D shoulder arthroplasty implant planning is traditionally done manually and can be time-consuming. Systems like Blueprint © are now using software features that suggest implant positioning and sizing. This study is a comparative evaluation of preoperative planning software, assessing user interaction efficiency by comparing the time and number of actions required to complete planning tasks with and without automated planning features. Materials and Methods: Real world plannings log files extracted from preoperative software were used to compare the impact of the auto-planning suggestion feature on the time taken and the number of actions to perform shoulder surgical planning. Comparative analyses were performed across the two main groups (with and without auto-planning) and three subgroups divided on surgeon's experience. Results: A total of 7021 preoperative plannings done by 1018 surgeons were included. The auto-planning group included 65 surgeons with 780 plannings and the Manual group included 953 surgeons with 6241 plannings. The Blueprint® new preoperative auto-planning feature—marketed under the name “BP Assist”—reduced the number of actions during the planning process by 29% compared to manual planning. For the most complex cases, auto-planning reduced the planning time by 25%. The auto-planning feature used by new users resulted in preoperative planning times that were at least as fast—and often faster—than those of high experience users who planned manually, while also requiring fewer actions to complete the planning process. Conclusions: The integration of an auto-planning feature into preoperative software allowed for a reduction in the number of actions and the time spent during preoperative software-based planning process. Further research is needed to determine whether auto-planning represents a meaningful advancement in shoulder arthroplasty, with potential to support surgical efficiency and clinical decision-making.