Hong Jin Kong

Hong Jin Kong

Auto-generated profile, based on publicly available information

Hong Jin Kong

Professor of Medicine School of Medicine Chief Division of Gastroenterology Western Reserve University University Hospitals of Cleveland Cleveland Hyderabad Beijing Ohio India

Research Focus & Metrics

Academic Career Length

32Years (1995-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 February 2009 in Laser and Particle Beams
Verified
Journal Article
Closed access
PDF file
HKH.J. Kong
H.J. Kong
JSJae-sung Shin
Jae-sung Shin
JYJ.W. Yoon
J.W. Yoon
DBD.H. Beak
D.H. Beak
The beam combination method using stimulated Brillouin scattering phase conjugate mirrors (SBS-PCMs) is a promising technique for a high energy and high power laser output operating with a high repetition rate. The two-beam combined system was previously demonstrated with an amplitude dividing method. A four-beam combined laser system with amplitude dividing method is demonstrated in this work, and the phase stabilization experiment of this system is performed using the self phase control and the long-term stabilization technique. The phase differences between the SBS waves are stabilized with λ/30 and the fluctuation of the four-beam combined output energy is 6.16% during 2000 shots (200 s).

1 January 2004 in Optics Express
Verified
Journal Article
Open access
PDF file
JKJ. Kong
J. Kong
DTD. Y. Tang
D. Y. Tang
JLJinghui Lu
Jinghui Lu
KUK. Ueda
K. Ueda
HYH. Yagi
H. Yagi
TYT. Yanagitani
T. Yanagitani
We report on the experimental studies of a diode-end-pumped passively Q-switched Yb:Y2O3 ceramic laser with a GaAs wafer simultaneously as saturable absorber and output coupler. The Q-switched operation of the laser has an average output power of 0.51 W with a 17.7-W incident pump power. The Q-switched pulses with pulse energy of 7.7 µJ have been achieved. The minimum pulse width is measured to be about 50 ns with a repetition rate of 52.6 KHz. To our knowledge, this is the first demonstration on a passively Q-switched Yb:Y2O3 ceramic laser.

12 September 1996 in Electronics Letters
Verified
Journal Article
Closed access
DCD.I. Chang
D.I. Chang
MGM.J. Guy
M.J. Guy
SCS.V. Chernikov
S.V. Chernikov
JTJ.R. Taylor
J.R. Taylor
HKH.J. Kong
H.J. Kong
A single-frequency erbium fibre laser operating at 1.534 µm is demonstrated. Single frequency operation is achieved using the twisted mode technique. Using a self-heterodyne technique a detector-limited linewidth of 10 kHz was measured.

11 June 2010 in Optics Express
Verified
Journal Article
Open access
PDF file
YJYu Jin Jeong
Yu Jin Jeong
TLTae Woo Lim
Tae Woo Lim
YSYong Son
Yong Son
DYDong-Yol Yang
Dong-Yol Yang
HKHong-Jin Kong
Hong-Jin Kong
KLKwang-Sup Lee
Kwang-Sup Lee
Diverse movements using optical manipulation have been introduced. These are generally performed in the focal region of the laser beam. To achieve a wider range of movements based on precise motion transformation, an effective method for optical manipulation that overcomes the important obstacles such as small optical trapping forces, friction, and the viscosity of fluids is required. A multi-link system with an elastic joint is introduced that provides precise motion transformation and amplification. By considering the physical properties of the structure and the optical trapping force, an elastic micron-scale joint with the simple shape of a thin plate was designed. As a further example of a multi-link system with an elastic joint, a double 4-link system for motion enlargement was designed and fabricated. By performing experimental evaluations of the fabricated structures, it was confirmed that multi-link systems with an elastic joint were effective tools for precise motion transformation through optical manipulation.

20 May 2006 in Applied Optics
Verified
Journal Article
Closed access
PDF file
JCJin Choi
Jin Choi
TKT. H. Kim
T. H. Kim
HKH. J. Kong
H. J. Kong
JLJong Ung Lee
Jong Ung Lee
A novel imaging spectrometer can individually control spatial and spectral resolution by using zoom lenses as the foreoptics of the system and a focusing lens. By varying the focal length we can use the focusing lens to change the spatial and spectral dimensions; with the foreoptics, however, we can change only the spatial dimension. Therefore the spectral resolution and the spectral range are affected by the zoom ratio of the focusing lens, whereas the spatial resolution and the field of view are affected by the multiplication of the zoom ratios of the foreoptics and the focusing lens. By properly combining two zoom ratios, we can control the spectral resolution with a fixed spatial resolution or the spatial resolution with a fixed spectral resolution. For an imaging spectrometer with this novel zooming function, we used the lens module method and third-order aberration theory to design an initial four-group zoom system with an external entrance pupil for the focusing lens. Furthermore, using the optical design software CODE V, we obtained an optimized zoom lens with a focal-length range of 50 to 150  mm. Finally, the zoom system with its transmission grating in the Littrow configuration performs satisfactorily as the focusing lens of an imaging spectrometer in the wavelength range 450–900 nm.

1 August 1995 in Japanese Journal of Applied Physics
Verified
Journal Article
Closed access
KHK. G. Han
K. G. Han
HKH. J. Kong
H. J. Kong
We report on the four-pass amplifier which has operational reliability for dumping an amplified pulse and produces no hot spot which usually causes optically induced damage in the gain medium. By compensating for the polarization distortion caused by thermal birefringence, we could obtain the gain of 2.5×105 from the amplifier. Without compensating for the polarization distortion, we could not obtain the gain larger than 6×103 because of lasing and generation of a large number of pulses.