Sofia Griff

Sofia Griff

Auto-generated profile, based on publicly available information

Sofia Griff

Wake Forest University School of Medicine, Winston-Salem, NC, USA

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 February 2021 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Closed access
PDF file
JHJamie K. Hu
Jamie K. Hu
HSHee-Won Suh
Hee-Won Suh
MQMunibah Qureshi
Munibah Qureshi
JLJulia M. Lewis
Julia M. Lewis
SYSharon Yaqoob
Sharon Yaqoob
MGMichael Girardi
Michael Girardi
Significance: One in five individuals in the United States will develop skin cancer over the course of a lifetime, and nonsurgical options are limited. To address this, we developed a bioadhesive nanoparticle (BNP) treatment for long-lasting local drug delivery. Incorporation of the topoisomerase inhibitor camptothecin (CPT) into BNPs enhanced tumor cell uptake, bioadhesion within the tumor microenvironment, and prolonged intratumoral drug retention. Therefore, we investigated BNPs encapsulating CPT as a local, nonsurgical treatment for nodular squamous cell carcinoma (SCC) skin cancers in a mouse model. BNP-CPT treatment facilitated tumor destruction and resolution, and was compatible with local immunotherapy. These findings suggest that BNP delivery of antitumor agents may provide opportunities for nonsurgical treatment of nodular skin cancers like SCC.

19 August 2025 in JSES Reviews, Reports, and Techniques
Verified
Journal Article
Open access
SSSujeeth K. Shanmugam
Sujeeth K. Shanmugam
SGSofia Griff
Sofia Griff
BPBryce Polascik
Bryce Polascik
NTNicholas A. Trasolini
Nicholas A. Trasolini
BWBrian R. Waterman
Brian R. Waterman
ARAlan Reynolds
Alan Reynolds
Poor bone mineral density (BMD) has been linked with poor healing and outcomes in the operative management of rotator cuff repair. The deltoid tuberosity index (DTI) has shown promise as an affordable and opportunistic indicator of BMD for patients with proximal humerus fractures. DTI could be a useful preoperative screening tool for BMD among patients indicated for rotator cuff repair. This study aims to evaluate whether DTI can be used as a reliable alternative to dual-energy x-ray absorptiometry (DEXA) for approximating BMD in patients undergoing shoulder arthroscopy. A retrospective chart review was conducted on patients undergoing shoulder arthroscopy who had previously had a DEXA scan and had an x-ray of the shoulder done within one year of the DEXA scan. DEXA T-scores and density values of the spine and femoral neck were collected from patient medical records and compared to cortical measurements from radiographs of the shoulder used to calculate DTI. Regression analysis was performed to compare DTI to DEXA T-scores and DEXA BMD of the spine and femoral neck. Inter-rater and intrarater repeatability were also assessed using intraclass correlation coefficients. 134 patients (115 female and 19 male) were included with an average age of 69 years. For DTI measurements, intraclass correlation coefficient values were 0.94 (95% CI, 0.85 to .98) for intrarater and 0.88 (95% CI, 0.77 to 0.95) for inter-rater reliability. Regression analysis showed a weak positive correlation between DTI and DEXA T-scores of the femoral neck (r = 0.29, P = .0007); DEXA T-scores of the spine (r = 0.26, P = .0026); DEXA BMD of the femoral neck (r = 0.20, P = .0201); and DEXA BMD of the spine (r = 0.19, P = .0341). DTI only weakly correlates with DEXA T-scores and BMD measurements for patients undergoing shoulder arthroscopy. DTI may not be a reliable screening tool for BMD in these patients and should be relied upon with caution outside of application to osteopenic fracture patients.

4 June 2026 in Clinics in Shoulder and Elbow
Verified
Journal Article
Open access
PDF file
SGSofia Griff
Sofia Griff
NDNoah E DiNapoli
Noah E DiNapoli
JRJames A Rhead
James A Rhead
GBGarrett S Bullock
Garrett S Bullock
BWBrian R Waterman
Brian R Waterman
ARAlan Reynolds
Alan Reynolds
Background: The optimization of implant positioning in reverse shoulder arthroplasty produces evolving and conflicting data. The distalization-lateralization index (DLI) has been introduced as a measurement that combines both lateralization and distalization. This study aimed to determine whether legacy and novel measurements correlate with patient reported outcomes.Methods: Patients who underwent primary reverse shoulder arthroplasty at a single institution between 2016 and 2022 and had a minimum of 2 years of follow up were screened by retrospective chart review. Radiographs were used to measure the lateralization shoulder angle, distalization shoulder angle, acromiohumeral interval (AHI), acromiohumeral offset (AHO), and glenohumeral offset (GHO). DLI and ΔDLI were calculated from the ΔAHI and ΔAHO. A linear regression analysis was performed to identify correlations between any measurements and the postoperative American Shoulder and Elbow Surgeons (ASES) score.Results: Data were analyzed from 140 patients with an average age of 71 years and average follow up of 3.3 years. AHO had an adjusted mean difference of –0.29 (P=0.009) between high and low ASES score groups. There was a weak, but statistically significant association between the ASES score and the DLI (r=0.181, P=0.032) in the simple linear regression, but no association was found in the multivariable linear regression, β=0.46 (95% CI, –0.04 to 0.95; P=0.072).Conclusions: Increased DLI was found to be weakly associated with higher ASES scores in the univariate analysis, but not after controlling for other variables. Although the correlation was not statistically significant, both the DLI and GHO were associated with higher ASES scores in the multivariate analysis, warranting further study with larger patient cohorts.Level of evidence: III.

10 April 2026 in HAND
Verified
Journal Article
Closed access
SGSofia Griff
Sofia Griff
LNLauren Neal
Lauren Neal
JCJuliet Chung
Juliet Chung
BGBenjamin R. Graves
Benjamin R. Graves
Artificial intelligence has the potential to assist in the interpretation of radiographs. The distal radius is one of the most commonly fractured bones, and accurate and timely diagnosis is required for proper treatment. This review aims to summarize the current literature on the use of artificial intelligence, particularly convolutional neural networks, in diagnosing distal radius fractures. The results indicate that artificial intelligence has shown increasingly improved performance with image interpretation over time, often on par with specialized physicians. However, these models still struggle with complex fractures.

26 October 2025 in Injury
Verified
Journal Article
Open access
EBEmily Barr
Emily Barr
SGSofia Griff
Sofia Griff
KHKaitlin Henry
Kaitlin Henry
CSChristian Sangio
Christian Sangio
GBGarrett Bullock
Garrett Bullock
HPHolly Pilson
Holly Pilson
To analyze the anatomy of the sternum and manubrium with a focus on the proximity of vital posterior structures to provide surgeons with guidelines for screw length and to increase awareness of locations for the safest hardware placement. A retrospective chart review was conducted at a level one trauma center in the southeastern United States. Patients with a chest CT in 2022 without evidence of abnormalities or prior cardiac or thoracic surgery, chest trauma, or sternotomy were included in the study. The primary study measures were dimensions of the manubrium and sternum and distances to nearby structures including the right atrial appendage, the main pulmonary artery, ascending aorta, right brachiocephalic artery, superior vena cava, and left and right brachiocephalic veins. 20 male (mean body mass index 29.0, mean age 50.5) and 20 female (mean body mass index 28.9, mean age 64.7) subjects were included. The smallest depth measurements of the manubrium and sternum were 10.3/9.3 mm (male/female) and 10.1/9.2 mm (m/f), respectively. The closest structures behind the manubrium were the left and right brachiocephalic veins with mean distances of 9.8/6.3 mm (m/f) and 15.5/13.5 mm (m/f), respectively. This was followed by the right brachiocephalic artery with mean distances of 20.9/16.4 mm (m/f). The closest structure behind the sternum was the right ventricle with mean distances of 8.5/8.4 mm (m/f), then the right atrial appendage with mean distances of 24.6/21.4 mm (m/f). Inter-rater reliability exceeded 0.80, indicating good reliability. Proximity of vital structures behind the sternum and manubrium creates challenges for bicortical screw fixation of the sternum and manubrium. Females had shorter distances indicating greater potential for injury. Understanding locations of vital structures can assist in preoperative planning and decrease complications.

16 October 2026 in Orthopaedic Journal of Sports Medicine
Verified
Journal Article
Open access
ECEthan S. Cui
Ethan S. Cui
MEMina Entessari
Mina Entessari
SGSofia Griff
Sofia Griff
ARAlexander S. Riddell
Alexander S. Riddell
PCPaul J. Carapellotti
Paul J. Carapellotti
BWBrian R. Waterman
Brian R. Waterman
Background: Quadriceps tendon (QT) autografts are increasingly being used for anterior cruciate ligament (ACL) reconstruction, although concerns for graft elongation and early graft failure persist. Suture tape augmentation was introduced to prevent excessive forces on remodeling graft tissue, but graft-specific data for QT autografts with suture tape augmentation remain limited. Purpose: To evaluate short-term patient-reported outcome measures (PROMs), return-to-sport rates, postoperative complications, and graft rerupture rates in patients undergoing primary ACL reconstruction with QT autograft with and without suture tape augmentation. Study Design: Cohort study; Level of evidence, 3. Methods: A retrospective review was performed at a single institution evaluating patients younger than 40 years who underwent primary ACL reconstruction with all soft tissue QT autograft between 2017 and 2024. Patients were stratified into 2 cohorts with and without suture tape augmentation. Demographic data, surgical characteristics, PROMs, time to return to sport, postoperative activity level as categorized by level of athletic participation, postoperative complications, graft rerupture, and reoperation rates were recorded. Minimum follow-up was 2 years. Continuous variables were compared using Welch t test or Mann-Whitney U test, and categorical variables were analyzed using chi-square and Fisher exact tests. Results: Of 225 patients initially identified, 80 (35%) were included in the final data analysis (42 controls, 38 augmented). Demographic, preoperative PROMs, and injury characteristics were similar between groups. At 2-year follow-up, no significant differences were found in PROMs, time to return to sport (41.2 vs 42.1 weeks; P = .8), or postoperative activity level. Graft rerupture occurred in 6 patients in the nonaugmented group (14%) and 0 patients in the augmented group (0%) ( P < .05). Among patients with graft rerupture, median time to failure was 109.5 weeks (range, 35-204 weeks), and mean time to failure was 109.3 ± 59.0 weeks. No significant differences in reoperation rate were found between cohorts. Conclusion: Suture tape augmentation of QT autografts for primary ACL reconstruction was associated with a significantly lower rate of early graft rerupture without differences in PROMs, return to sport, or reoperation rates compared with nonaugmented QT grafts.