12 December 2018 in Cancer Imaging
Cancer patients often have a history of chemotherapy, putting them at increased risk of liver toxicity and pancytopenia, leading to elevated liver fat and elevated liver iron respectively. T1-in-and-out-of-phase, the conventional MR technique for liver fat assessment, fails to detect elevated liver fat in the presence of concomitantly elevated liver iron. IDEAL-IQ is a more recently introduced MR fat quantification method that corrects for multiple confounding factors, including elevated liver iron. This retrospective study was approved by the institutional review board with a waiver for informed consent. We reviewed the MRI studies of 50 cancer patients (30 males, 20 females, 50–78 years old) whose exams included (1) T1-in-and-out-of-phase, (2) IDEAL-IQ, and (3) T2* mapping. Two readers independently assessed fat and iron content from conventional and IDEAL-IQ MR methods. Intraclass correlation coefficient (ICC) was estimated to evaluate agreement between conventional MRI and IDEAL-IQ in measuring R2* level (a surrogate for iron level), and in measuring fat level. Agreement between the two readers was also assessed. Wilcoxon signed rank test was employed to compare iron level and fat fraction between conventional MRI and IDEAL-IQ. Twenty percent of patients had both elevated liver iron and moderate/severe hepatic steatosis. Across all patients, there was high agreement between readers for IDEAL-IQ fat fraction (ICC = 0.957) and IDEAL R2* (ICC = 0.971) measurements, but lower agreement for conventional fat fraction measurements (ICC = 0.626). The fat fractions calculated with IOP were statistically significantly different from those calculated with IDEAL-IQ (reader 1: p < 0.001, reader 2: p < 0.001). Fat measurements using IDEAL-IQ and IOP diverged in patients with concomitantly elevated liver fat and liver iron. Given prior work validating IDEAL-IQ, these diverging measurements indicate that IOP is inadequate to screen for hepatic steatosis in our cancer population.
1 January 2019 in Journal of Computer Assisted Tomography
Rationale and Objectives: The purpose of this study is to compare image quality, presence and grade of artifacts, signal-to-noise ratio, and apparent diffusion coefficient (ADC) values in pancreatic tissue between high-resolution navigator-triggered (NT) restricted field of view (rFOV) FOCUS single-shot (SS) echo-planar imaging (EPI) diffusion-weighted imaging (DWI) and NT large FOV SS-EPI DWI. Materials and Methods: Magnetic resonance imaging examinations were performed with GE 3-T systems using a 32-channel body array coil. Seventeen consecutive patients were imaged. A 5-point scale semiquantitative grading system was used to evaluate image quality and general artifacts. Signal-to-noise ratio and ADC were measured in the head, body, and tail of the pancreas. Statistical analysis was performed using Student t test and Wilcoxon signed rank test, with differences considered significant for P value less than 0.05. Results: More artifacts were present on large FOV compared with rFOV FOCUS SS-EPI DW images (P < 0.01). Restricted field of view image quality was subjectively better (P < 0.01). No difference in the signal-to-noise ratio was demonstrated between the 2 image datasets. Apparent diffusion coefficient values were significantly lower (P < 0.01) when calculated from rFOV images than large FOV images. Conclusions: Our results demonstrate better image quality and reduced artifacts in rFOV images compared with large FOV DWI. Measurements from ADC maps derived from rFOV DWI show significantly lower ADC values when compared with ADC maps derived from large FOV DWI.
1 November 2018 in Clinical Imaging
1 July 2018 in Academic Radiology
24 September 2018 in Abdominal Radiology
SCSandra Huicochea Castellanos
Sandra Huicochea Castellanos
+4
28 January 2019 in European Radiology
SHSandra Huicochea-Castellanos
Sandra Huicochea-Castellanos
+15