Hamed Saeidi

Hamed Saeidi

Auto-generated profile, based on publicly available information

Hamed Saeidi

Department of Computer Science, University of North Carolina Wilmington, Wilmington, NC 28403, USA

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 January 2022 in Science Robotics
Verified
Journal Article
Closed access
HSH. Saeidi
H. Saeidi
JOJ. D. Opfermann
J. D. Opfermann
MKM. Kam
M. Kam
SWShuwen Wei
Shuwen Wei
SLS. Leonard
S. Leonard
AKAxel Krieger
Axel Krieger
Autonomous robotic surgery has the potential to provide efficacy, safety, and consistency independent of individual surgeon’s skill and experience. Autonomous anastomosis is a challenging soft-tissue surgery task because it requires intricate imaging, tissue tracking, and surgical planning techniques, as well as a precise execution via highly adaptable control strategies often in unstructured and deformable environments. In the laparoscopic setting, such surgeries are even more challenging because of the need for high maneuverability and repeatability under motion and vision constraints. Here we describe an enhanced autonomous strategy for laparoscopic soft tissue surgery and demonstrate robotic laparoscopic small bowel anastomosis in phantom and in vivo intestinal tissues. This enhanced autonomous strategy allows the operator to select among autonomously generated surgical plans and the robot executes a wide range of tasks independently. We then use our enhanced autonomous strategy to perform in vivo autonomous robotic laparoscopic surgery for intestinal anastomosis on porcine models over a 1-week survival period. We compared the anastomosis quality criteria—including needle placement corrections, suture spacing, suture bite size, completion time, lumen patency, and leak pressure—of the developed autonomous system, manual laparoscopic surgery, and robot-assisted surgery (RAS). Data from a phantom model indicate that our system outperforms expert surgeons’ manual technique and RAS technique in terms of consistency and accuracy. This was also replicated in the in vivo model. These results demonstrate that surgical robots exhibiting high levels of autonomy have the potential to improve consistency, patient outcomes, and access to a standard surgical technique.

1 May 2019
Verified
Conference Paper
Closed access
HSH. Saeidi
H. Saeidi
HLH. N. D. Le
H. N. D. Le
JOJ. D. Opfermann
J. D. Opfermann
SLS. Leonard
S. Leonard
AKA. Kim
A. Kim
AKA. Krieger
A. Krieger
Compared to open surgical techniques, laparoscopic surgical methods aim to reduce the collateral tissue damage and hence decrease the patient recovery time. However, constraints imposed by the laparoscopic surgery, i.e. the operation of surgical tools in limited spaces, turn simple surgical tasks such as suturing into time-consuming and inconsistent tasks for surgeons. In this paper, we develop an autonomous laparoscopic robotic suturing system. More specific, we expand our smart tissue anastomosis robot (STAR) by developing i) a new 3D imaging endoscope, ii) a novel actuated laparoscopic suturing tool, and iii) a suture planning strategy for the autonomous suturing. We experimentally test the accuracy and consistency of our developed system and compare it to sutures performed manually by surgeons. Our test results on suture pads indicate that STAR can reach 2.9 times better consistency in suture spacing compared to manual method and also eliminate suture repositioning and adjustments. Moreover, the consistency of suture bite sizes obtained by STAR matches with those obtained by manual suturing.

12 December 2018 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
HSHamed Saeidi
Hamed Saeidi
YWYue Wang
Yue Wang

1 October 2018
Verified
Conference Paper
Closed access
HSH. Saeidi
H. Saeidi
JOJustin D. Opfermann
Justin D. Opfermann
MKMichael Kam
Michael Kam
SRSudarshan Raghunathan
Sudarshan Raghunathan
SLS. Leonard
S. Leonard
AKAxel Krieger
Axel Krieger
Autonomous robotic assisted surgery (RAS) systems aim to reduce human errors and improve patient outcomes leveraging robotic accuracy and repeatability during surgical procedures. However, full automation of RAS in complex surgical environments is still not feasible and collaboration with the surgeon is required for safe and effective use. In this work, we utilize our Smart Tissue Autonomous Robot (STAR) to develop and evaluate a shared control strategy for the collaboration of the robot with a human operator in surgical scenarios. We consider 2D pattern cutting tasks with partial blood occlusion of the cutting pattern using a robotic electrocautery tool. For this surgical task and RAS system, we i) develop a confidence-based shared control strategy, ii) assess the pattern tracking performances of manual and autonomous controls and identify the confidence models for human and robot as well as a confidence-based control allocation function, and iii) experimentally evaluate the accuracy of our proposed shared control strategy. In our experiments on porcine fat samples, by combining the best elements of autonomous robot controller with complementary skills of a human operator, our proposed control strategy improved the cutting accuracy by 6.4%, while reducing the operator work time to 44% compared to a pure manual control.

28 October 2019 in IEEE Transactions on Medical Robotics and Bionics
Verified
Journal Article
Closed access
HSH. Saeidi
H. Saeidi
JGJ. Ge
J. Ge
MKM. Kam
M. Kam
JOJ. D. Opfermann
J. D. Opfermann
SLS. Leonard
S. Leonard
AKAxel Krieger
Axel Krieger
Autonomous robotic surgery systems aim to improve patient outcomes by leveraging the repeatability and consistency of automation and also reducing human induced errors. However, intraoperative autonomous soft tissue tracking and robot control still remains a challenge due to the lack of structure, and high deformability of such tissues. In this paper, we take advantage of biocompatible Near-Infrared (NIR) marking methods and develop a supervised autonomous 3D path planning, filtering, and control strategy for our Smart Tissue Autonomous Robot (STAR) to enable precise and consistent incisions on complex 3D soft tissues. Our experimental results on cadaver porcine tongue samples indicate that the proposed strategy reduces surface incision error and depth incision error by 40.03% and 51.5%, respectively, compared to a teleoperation strategy via da Vinci. Furthermore, compared to an autonomous path planning method with linear interpolation between the NIR markers, the proposed strategy reduces the incision depth error by 48.58% by taking advantage of 3D tissue surface information.

12 December 2023 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
JGJiawei Ge
Jiawei Ge
MKMichael Kam
Michael Kam
JOJustin Opfermann
Justin Opfermann
HSHamed Saeidi
Hamed Saeidi
SLSimon Leonard
Simon Leonard
AKAxel Krieger
Axel Krieger
Head and neck cancers are the seventh most common cancers worldwide, with squamous cell carcinoma being the most prevalent histologic subtype. Surgical resection is a primary treatment modality for many patients with head and neck squamous cell carcinoma, and accurately identifying tumor boundaries and ensuring sufficient resection margins are critical for optimizing oncologic outcomes. This letter presents an innovative autonomous system for tumor resection (ASTR) and conducts a feasibility study by performing supervised autonomous midline partial glossectomy for pseudotumor with millimeter accuracy. The proposed ASTR system consists of a dual-camera vision system, an electrosurgical instrument, a newly developed vacuum grasping instrument, two 6-DOF manipulators, and a novel autonomous control system. The letter introduces an ontology-based research framework for creating and implementing a complex autonomous surgical workflow, using the glossectomy as a case study. Porcine tongue tissues are used in this study, and marked using color inks and near-infrared fluorescent (NIRF) markers to indicate the pseudotumor. ASTR actively monitors the NIRF markers and gathers spatial and color data from the samples, enabling planning and execution of robot trajectories in accordance with the proposed glossectomy workflow. The system successfully performs six consecutive supervised autonomous pseudotumor resections on porcine specimens. The average surface and depth resection errors measure $0.73\pm 0.60$ $\text{mm}$ and $1.89\pm 0.54$ $\text{mm}$, respectively, with no positive tumor margins detected in any of the six resections. The resection accuracy is demonstrated to be on par with manual pseudotumor glossectomy performed by an experienced otolaryngologist.