Pradeep Gupta

Pradeep Gupta

Auto-generated profile, based on publicly available information

Pradeep Gupta

Interdisciplinary Centre for Energy Research, Indian Institute of Science, Bengaluru 560012, India

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2019 in Physics of Fluids
Verified
Journal Article
Closed access
PDF file
PGPradeep Gupta
Pradeep Gupta
SRSrisha M. V. Rao
Srisha M. V. Rao
PKPramod Kumar
Pramod Kumar
Ejectors have many applications in aerospace and energy conversion technologies. An ejector is a passive device that pumps a secondary fluid by energy augmentation from a primary fluid. The performance of the ejector is primarily dependent on the complex gas dynamic interactions between the primary and secondary flows in a variable area duct. The maximum mass flow rate of the ejector in the critical flow regime is limited by choking of both the primary and secondary flows. This paper focuses on experimental investigations on the mixing characteristics of the ejector having an area ratio of 2 in the critical flow regime for a range of stagnation pressure ratios varying between 5.49 and 11.12 and a primary Mach number of 1.5, 2.0, and 2.5. The gas dynamic flow field is visualized using non-invasive high-speed schlieren and Mie-scattering techniques. Mie-scattering images are used to gain insight into the mixing characteristics and estimate the non-mixed length. The optical measurements are complimented with the wall static pressure measurements. The experimental performance data are compared with two well-established analytical models. The characterization of the mixing in the critical operating regime of the ejector using optical tools is being reported here for the first time. An important outcome of the paper is the observation of a significant increment in the non-mixed length to the tune of 55% increase in the critical flow regime in comparison to the mixed flow regime.

1 January 2022 in Applied Thermal Engineering
Verified
Journal Article
Closed access
PGPradeep Gupta
Pradeep Gupta
PKPramod Kumar
Pramod Kumar
SRSrisha M.V. Rao
Srisha M.V. Rao

23 July 2022 in Applied Thermal Engineering
Verified
Journal Article
Closed access
PGPradeep Gupta
Pradeep Gupta
PKPramod Kumar
Pramod Kumar
SRSrisha M.V. Rao
Srisha M.V. Rao

1 March 2023 in Physics of Fluids
Verified
Journal Article
Closed access
PDF file
PGPradeep Gupta
Pradeep Gupta
PKPramod Kumar
Pramod Kumar
SRSrisha M. V. Rao
Srisha M. V. Rao
Supersonic ejectors are passive gasdynamic devices that compress a low-pressure fluid by utilizing the kinetic energy of a high-pressure fluid in a variable area duct. The ejector consists of a primary supersonic nozzle in a mixing duct where the secondary flow is entrained and mixed. The mixed flow can undergo a series of recompression shocks resulting in a subsonic flow in the diverging portion to aid pressure recovery. Recompression shocks usually lead to unsteady shock boundary layer interactions. The performance of the ejector is influenced by shear layers, shock and expansion waves, and their mutual interactions. While existing literature has extensively dealt with mixing of the primary and secondary flows, the unsteadiness in flow resulting from recompression shocks has been seldom investigated. Fluctuations in pressure due to the unsteadiness of the shock often lead structural fatigue issues. This paper reports a detailed investigation on low-frequency unsteadiness of recompression shock using high-speed schlieren images and dynamic pressure measurements. Modal analyses using proper orthogonal decomposition and dynamic mode decomposition techniques are used to determine the dominant spatial modes and associated frequencies. Multimodal frequencies ranging between 80 and 300 Hz are observed. These findings are further corroborated by Fourier and wavelet transformations of the experimentally measured wall static pressure signals. Subsequently, scaling parameter is established for the dominant frequencies based on flow velocities upstream of the shock and the distance between two consecutive shocks. This results in a unique scaling frequency of 4.58% ± 18%, for the recompression shock independent of operating conditions.

1 January 2019
Verified
Conference Paper
Closed access
PGPradeep Gupta
Pradeep Gupta
SMSrisha Rao Mv
Srisha Rao Mv
PKPramod Kumar
Pramod Kumar

28 March 2023 in Sādhanā
Verified
Journal Article
Closed access
PDF file
PGPradeep Gupta
Pradeep Gupta
SRSrisha M V Rao
Srisha M V Rao
PKPramod Kumar
Pramod Kumar