Pramod Kumar

Pramod Kumar

Auto-generated profile, based on publicly available information

Pramod Kumar

Interdisciplinary Centre for Energy Research, Indian Institute of Science 1 , Bangalore 560012

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2003 in Metallurgical and Materials Transactions B
Verified
Journal Article
Closed access
PDF file
PKP. Kumar
P. Kumar
KSK. Srinivasan
K. Srinivasan
PDP. Dutta
P. Dutta
Suman ChakrabortySuman Chakraborty
Suman Chakraborty

11 April 2023 in International Journal of Hydrogen Energy
Verified
Journal Article
Closed access
KMK. Malleswararao
K. Malleswararao
PKPramod Kumar
Pramod Kumar
PDPradip Dutta
Pradip Dutta
SMS. Srinivasa Murthy
S. Srinivasa Murthy

1 January 2011
Verified
Conference Paper
Closed access
PDF file
HCHui Chen
Hui Chen
MKMukil Kesavan
Mukil Kesavan
KSKarsten Schwan
Karsten Schwan
AGAda Gavrilovska
Ada Gavrilovska
PKPramod Kumar
Pramod Kumar
YJYogendra Joshi
Yogendra Joshi
Energy efficiency in data center operation depends on many factors, including power distribution, thermal load and consequent cooling costs, and IT management in terms of how and where IT load is placed and moved under changing request loads. Current methods provided by vendors consolidate IT loads onto the smallest number of machines needed to meet application requirements. This paper’s goal is to gain further improvements in energy efficiency by also making such methods ‘spatially aware’, so that load is placed onto machines in ways that respect the efficiency of both cooling and power usage, across and within racks. To help implement spatially aware load placement, we propose a model-based reinforcement learning method to learn and then predict the thermal distribution of different placements for incoming workloads. The method is trained with actual data captured in a fully instrumented data center facility. Experimental results showing notable differences in total power consumption for representative application loads indicate the utility of a two-level spatially-aware workload management (SpAWM) technique in which (i) load is distributed across racks in ways that recognize differences in cooling efficiencies and (ii) within racks, load is distributed so as to take into account cooling effectiveness due to local air flow. The technique is being implemented using online methods that continuously monitor current power and resource usage within and across racks, sense BladeCenter-level inlet temperatures, understand and manage IT load according to an environment’s thermal map. Specifically, at data center level, monitoring informs SpAWM about power usage and thermal distribution across racks. At rack-level, SpAWM workload distribution is based on power caps provided by maximum inlet temperatures determined by CRAC speeds and supply air temperature. SpAWM can be realized as a set of management methods running in VMWare’s ESXServer virtualization infrastructure. Its use has the potential of attaining up to 32% improvements on the CRAC supply temperature requirement compared to non-spatially aware techniques, which can lower the inlet temperature 2∼3°C, that is to say we can increase the CRAC supply temperature 2∼3°C to save nearly 13% −18% cooling energy.

1 March 2023 in Physics of Fluids
Verified
Journal Article
Closed access
PDF file
PGPradeep Gupta
Pradeep Gupta
PKPramod Kumar
Pramod Kumar
SRSrisha M. V. Rao
Srisha M. V. Rao
Supersonic ejectors are passive gasdynamic devices that compress a low-pressure fluid by utilizing the kinetic energy of a high-pressure fluid in a variable area duct. The ejector consists of a primary supersonic nozzle in a mixing duct where the secondary flow is entrained and mixed. The mixed flow can undergo a series of recompression shocks resulting in a subsonic flow in the diverging portion to aid pressure recovery. Recompression shocks usually lead to unsteady shock boundary layer interactions. The performance of the ejector is influenced by shear layers, shock and expansion waves, and their mutual interactions. While existing literature has extensively dealt with mixing of the primary and secondary flows, the unsteadiness in flow resulting from recompression shocks has been seldom investigated. Fluctuations in pressure due to the unsteadiness of the shock often lead structural fatigue issues. This paper reports a detailed investigation on low-frequency unsteadiness of recompression shock using high-speed schlieren images and dynamic pressure measurements. Modal analyses using proper orthogonal decomposition and dynamic mode decomposition techniques are used to determine the dominant spatial modes and associated frequencies. Multimodal frequencies ranging between 80 and 300 Hz are observed. These findings are further corroborated by Fourier and wavelet transformations of the experimentally measured wall static pressure signals. Subsequently, scaling parameter is established for the dominant frequencies based on flow velocities upstream of the shock and the distance between two consecutive shocks. This results in a unique scaling frequency of 4.58% ± 18%, for the recompression shock independent of operating conditions.

15 February 2012
Verified
Book Chapter
Closed access
PDF file
PKPramod Kumar
Pramod Kumar
YJYogendra Joshi
Yogendra Joshi

15 December 2021
Verified
Conference Paper
Closed access
KPKamisetti N V Prasad
Kamisetti N V Prasad
APAshutosh Patel
Ashutosh Patel
VBVijay Biradar
Vijay Biradar
SASyed Shahjahan Ahmad
Syed Shahjahan Ahmad
PKPramod Kumar
Pramod Kumar
GNG. Narayanan
G. Narayanan
In this paper, various mechanical and electrical reasons and methods to prevent bearing failures are highlighted. The bearing selection for a 5 kW, 10,000 rpm switched reluctance machine (SRM) is carried out by estimating axial and radial forces acting on the rotor assembly and various other bearing parameters. The rotor weight and forces due to the rotation of unbalance residue mass is considered as radial force. To handle axial and radial forces, angular contact bearing is selected. The expected bearing life and corresponding axial loads are estimated. The selected bearings are installed in SRM. Further, the SRM is operated at various speeds with closed-loop speed control using a SiC-based asymmetric H-bridge converter. The bearing performance is validated by measuring vibration on bearing housings at a speed of 10,500 rpm.