Tripta Thakur

Tripta Thakur

Auto-generated profile, based on publicly available information

Tripta Thakur

Electrical Engineering Department, Maulana Azad National Institute of Technology, Bhopal, India

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

25 January 2021 in Journal of Control, Automation and Electrical Systems
Verified
Journal Article
Closed access
PDF file
DMDeepthisree Madathil
Deepthisree Madathil
DVDr. Ravikumar Pandi Veerappan
Dr. Ravikumar Pandi Veerappan
Manjula NairManjula Nair
Manjula Nair
TJTooraj Jamasb
Tooraj Jamasb
TTTripta Thakur
Tripta Thakur

1 June 2021 in Economic Analysis and Policy
Verified
Journal Article
Closed access
TJTooraj Jamasb
Tooraj Jamasb
MLManuel Llorca
Manuel Llorca
PKPavan Khetrapal
Pavan Khetrapal
TTTripta Thakur
Tripta Thakur

1 May 2017 in Journal of Renewable and Sustainable Energy
Verified
Journal Article
Closed access
BBBaidyanath Bag
Baidyanath Bag
TTTripta Thakur
Tripta Thakur
Globally, environmental concerns have become the main motive behind energy management to save energy. The compelling rise in security threats due to gradual depletion of conventional energy sources, carbon emissions, global warming, and hikes in global energy prices has increased the global need for energy saving. In this paper, a simple but cost-effective method for energy management through energy saving has been proposed. The proposed method shows that the consumption level of the voltage regulated loads (constant impedance types) can be reduced by a significant amount by reducing input voltage across them while keeping the lowest customer utilization voltage consistent. The reduction in the consumption level also ensures significant reduction in line losses through reduced line flows. The network capacity release due to reduced line flows is also indicative, which prevents investment deferral required for further expansion in network capacity to meet the growing demand. The proposed method is not only beneficial to consumer savings through reduced demand but also enhances appliances' lives, as their operation is at low voltage which again does not affect their performances. On the other hand, although a utility loses revenue due to reduced energy usage among consumers, it is being benefitted indirectly. Indirect benefits include network capacity release, avoided prices for power-purchase during supply-demand gap, net loss reduction including transformers and distribution lines, potential incentives from regulators, fuel preservation, emission reduction, etc. The proposed method is tested on an IEEE 33-bus system, and the results show that an energy saving of 5.91% per year can be achieved.

25 July 2018 in Iranian Journal of Science and Technology, Transactions of Electrical Engineering
Verified
Journal Article
Closed access
PDF file
HCHemanthakumar Chappa
Hemanthakumar Chappa
TTTripta Thakur
Tripta Thakur

19 July 2023 in Sustainability
Verified
Journal Article
Open access
PDF file
SSSreelekshmi R S
Sreelekshmi R S
Manjula NairManjula Nair
Manjula Nair
VKVyshak K.
Vyshak K.
SKSarika Khushalani-Solanki
Sarika Khushalani-Solanki
TTTripta Thakur
Tripta Thakur
The high penetration of renewable energy sources has necessitated the use of more energy-storage devices in Smartgrids. The proposed work addresses the development and implementation of an Instantaneous Discharge Controller (IDC) for a hybrid energy storage system. The discharge control algorithm manages the discharge of the battery and supercapacitor and protects the battery from transient currents. Hybrid energy storage systems (HESSs) are well known for providing ideal attributes such as high-power density and high-energy density for many application areas, including electric vehicles and renewable energy-supported microgrids. However, the application of HESSs for supporting shunt active filters and protecting low power density storage systems from fast variations in load has not been proposed yet. In this context, a hybrid energy storage system (HESS) is proposed here to eliminate harmonics and to support the grid by providing real and reactive power supervened by varying load conditions. This paper proffers an innovative controller for a shunt active filter unified with an HESS to effectively manage storage devices for a microgrid connected to a grid.