Mladen Tomic

Mladen Tomic

Auto-generated profile, based on publicly available information

Mladen Tomic

University of Novi Sad

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2017 in Energy
Verified
Journal Article
Closed access
BMBiljana Milutinović
Biljana Milutinović
GSGordana Stefanović
Gordana Stefanović
PĐPetar S. Đekić
Petar S. Đekić
IMIvan Mijailović
Ivan Mijailović
MTMladen Tomić
Mladen Tomić

11 June 2021 in Energies
Verified
Journal Article
Open access
PDF file
AAAleksandar Andjelkovic
Aleksandar Andjelkovic
MKMiroslav V. Kljajić
Miroslav V. Kljajić
DMDušan Macura
Dušan Macura
VMVladimir Munćan
Vladimir Munćan
IMIgor Mujan
Igor Mujan
BSBorivoj Stepanov
Borivoj Stepanov
A building energy performance gap can be illustrated as the difference between the theoretical (methodologically defined) and the actual energy consumption. In EU countries, Energy Performance Certificates are issued when buildings are constructed, sold, or leased. This information is the first step in order to evaluate the energy performance of the building stock. In Serbia, when issuing an energy certificate, the adopted national methodology recognizes only energy consumption for heating. The main purpose of this paper is to evaluate the energy gap and estimate the relevance of an Energy Performance Certificate to meet the national energy efficiency or carbon target. An Energy Performance Certificate determines the theoretical residential and commercial building energy efficiency or its “design intent”. This research stresses the necessity of measuring and achieving reductions in actual energy consumption through system regulation and consumers’ self-awareness in buildings. The research compares the performance of the building stock (135) that is connected to the District Heating System (DHS), with its own integrated heat meter, to Individual Gas Boiler (IGB) systems (18), in the city of Novi Sad, Serbia, built after 2014. For the purpose of comparing energy consumption, 16 buildings were selected that are very similar in terms of design, operation, and location. The data used are derived from metered consumption data, official evidence of city service companies, and Energy Performance Certificates of the considered buildings. We have determined that IGB systems have a much wider specific annual performance gap (11.19–101 kWh/m2a) than the buildings in the DHS (3.16–18.58 kWh/m2a).

9 February 2023 in Energy Sources, Part A: Recovery, Utilization, and Environmental Effects
Verified
Journal Article
Closed access
AMAleksandar V. Manojlović
Aleksandar V. Manojlović
OMOlivera M. Medar
Olivera M. Medar
AAAleksandar S. Anđelković
Aleksandar S. Anđelković
MTMladen A. Tomić
Mladen A. Tomić
Most of the air pollution originates from combustion processes, where traffic is one of the most important sources. Thus, road traffic’s contribution to pollution and overall emissions is very important. One of the popular methods for reducing pollution in urban areas is the introduction of electric vehicles (EV), and this is the main reason why fully electric vehicles, as an alternative to conventional fossil fuel vehicles, are becoming more popular. Although EVs emit no tailpipe pollutants, the power plants in national grid systems may emit them. This is the case with coal-based energy systems, like the one in the Republic of Serbia. In this study, the analysis of direct and indirect emissions of CO2 and NOX from ICE and EV is presented. The analysis has shown that the average specific emission factor for EVs, if charged in Serbia, is almost the same in terms of CO2 with 194.7 g/km in comparison with 159.6 g/km, while in the case of NOX, the specific emissions factors for EV almost doubles, from 0.71 to 1.30 g/km. Further analyses have shown that decarbonizing the national power grid to reduce the complete replacement of the fleet with EVs for achieving net zero emissions requires all the available solar, wind, and hydropower resources of the Republic of Serbia. On the other hand, EVs could be used as battery storage for discontinuous energy sources covering the needs of over 25% of a personal vehicle fleet.

1 January 2012 in Thermal Science
Verified
Journal Article
Open access
Ivan Toplica CiricIvan Toplica Ciric
Ivan Toplica Ciric
ZCZarko Cojbasic
Zarko Cojbasic
VNVlastimir Nikolic
Vlastimir Nikolic
PZPredrag Zivkovic
Predrag Zivkovic
MTMladen Tomic
Mladen Tomic
The subject of this study is to compare different computational intelligence methodologies based on artificial neural networks used for forecasting an air quality parameter - the emission of CO2, in the city of Nis. Firstly, inputs of the CO2 emission estimator are analyzed and their measurement is explained. It is known that the traffic is the single largest emitter of CO2 in Europe. Therefore, a proper treatment of this component of pollution is very important for precise estimation of emission levels. With this in mind, measurements of traffic frequency and CO2 concentration were carried out at critical intersections in the city, as well as the monitoring of a vehicle direction at the crossroad. Finally, based on experimental data, different soft computing estimators were developed, such as feed forward neural network, recurrent neural network, and hybrid neuro-fuzzy estimator of CO2 emission levels. Test data for some characteristic cases presented at the end of the paper shows good agreement of developed estimator outputs with experimental data. Presented results are a true indicator of the implemented method usability.

1 January 2014
Verified
Journal Article
Open access
MVMica Vukic
Mica Vukic
MTMladen Tomic
Mladen Tomic
PZPredrag Zivkovic
Predrag Zivkovic
GIGradimir Ilic
Gradimir Ilic
In this paper, the results of the experimental investigations of fluid flow and heat transfer in laboratory experimental shell-and-tube heat exchanger are presented. Shell-and-tube heat exchanger is with one pass of warm water on the shell side and two passes of cool water in tube bundle. Shell-and-tube heat exchanger is with 24x2 tubes (U-tube) in triangle layout. During each experimental run, the pressure drops and the fluid temperatures on shell side, along the shell-and-tube heat exchanger (at positions defined in advance) have been measured. Special attention was made to the investigation of the segmental baffles number influence of the shell-and-tube heat exchanger effectiveness.

1 January 2014 in Thermal Science
Verified
Journal Article
Open access
MTMladen Tomic
Mladen Tomic
BMBiljana Milutinovic
Biljana Milutinovic
PZPredrag Zivkovic
Predrag Zivkovic
PDPetar Djekic
Petar Djekic
ABAleksandra Boricic
Aleksandra Boricic
With the rapid development of information technology equipment and its use in the teaching and learning activities, the working environment (especially indoor air quality) in which students and pupils spend a great deal of time in educational institutions has been changing. Therefore, special attention must be paid to indoor air quality and comfort. It is of great importance to maintain indoor air quality in an object, such as information technology classrooms, where a large number of students spend long periods of time. Poor indoor environment can negatively affect scholarly performances and cause discomfort and poor work performance. The problem of indoor air quality in educational institutions can be more serious than in other types of objects, because of the higher concentration of students and information technology equipment. This paper analyzes the changes in air quality in an information technology classrooms, when occupied with students, for the period from March to April. The changes of indoor air temperature, relative humidity, and carbon dioxide concentration are monitored in the classroom, as well as outdoor temperature and relative humidity. Several cases are studied: the classroom with closed windows and doors (closed classroom), the classroom with natural ventilation, the classroom cooled with a split system (cooled classroom). Responses of students are followed for each case. The analysis is performed based on the measurement results and numerical simulations using the computational fluid dynamics package, and measures are proposed to improve the indoor air quality in the considered classroom.