Dongye Zhao

Dongye Zhao

Auto-generated profile, based on publicly available information

Dongye Zhao

Southwestern Institute of Physics, Chengdu, China

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2013 in Spectrochimica Acta Part B: Atomic Spectroscopy
Verified
Journal Article
Closed access
RHRan Hai
Ran Hai
NFNazar Farid
Nazar Farid
DZDongye Zhao
Dongye Zhao
LZLei Zhang
Lei Zhang
JLJiahong Liu
Jiahong Liu
GLGuang-Nan Luo
Guang-Nan Luo

1 July 2018 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
DZDongye Zhao
Dongye Zhao
CLCong Li
Cong Li
ZHZhenhua Hu
Zhenhua Hu
CFChunlei Feng
Chunlei Feng
QXQingmei Xiao
Qingmei Xiao
HDHongbin Ding
Hongbin Ding
The diagnosis of the fuel retention and impurity deposition on the plasma facing components (PFCs) is very important for monitoring plasma-wall interactions and improving the performance of long-pulse operation for tokamak devices. In this study, a remote in situ laser-induced breakdown spectroscopic (RIS-LIBS) system has been developed to be an effective and routine method for the diagnosis of the composition of the PFCs on Experimental Advanced Superconducting Tokamak (EAST). The RIS-LIBS system can be operated between EAST discharges via a remote network control system. This allows a flexible diagnosis for the PFCs at a specific EAST discharge operation or under planned plasma scenarios according to the experimental requirement. Measurements on the fuel retention and impurity deposition of the PFCs have been performed for the test of the RIS-LIBS system, and the depth resolution and the lateral resolution of the RIS-LIBS system have been achieved to be ∼100 nm and ∼3.0 mm, respectively. For the test of detectable elements, the fuel (deuterium) and impurities have been detected and identified clearly. In addition, the measurement of fuel abundance on the first wall as a function of the days of EAST deuterium plasma discharges has been carried out for the first time. These results well manifest a significant prospect of the RIS-LIBS for the diagnosis of the PFCs in the upcoming fusion devices like China Fusion Engineering Test Reactor (CFETR) and ITER.

1 August 2015 in Journal of Nuclear Materials
Verified
Journal Article
Closed access
CLCong Li
Cong Li
DZDongye Zhao
Dongye Zhao
ZHZhenhua Hu
Zhenhua Hu
XWXingwei Wu
Xingwei Wu
GLGuang-Nan Luo
Guang-Nan Luo
HDHongbin Ding
Hongbin Ding

9 April 2021 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Closed access
PDF file
DWDing Wu
Ding Wu
LSLiying Sun
Liying Sun
JLJiamin Liu
Jiamin Liu
YLYan Lyu
Yan Lyu
HWHuace Wu
Huace Wu
HDHongbin Ding
Hongbin Ding
Laser-induced breakdown spectroscopy (LIBS) is a promising method for the in situ online diagnosis of plasma–wall interaction processes in tokamaks. The effect of gas pressure on the plume expansion and spectral emission of nanosecond laser-induced plasma of the tungsten wall material was systematically investigated using a coaxial optical configuration. A nanosecond pulsed laser (5 ns, 1064 nm) was used to ablate a tungsten target surface to produce plasma at various air pressure levels from 10−3 Pa to 105 Pa. It was found that the plasma size was strongly dependent on the ambient gas pressure, and the plume presented complex behaviors such as free expansion, splitting, sharpening, confinement, etc. The spectral intensity, the signal to background ratio, and signal to noise ratio were also affected significantly by the ambient pressure. The ambient pressure influence on the plasma plume expansion and spectral emission can be ignored when the gas pressure is lower than ∼1 Pa. The pressure of 10–100 Pa and delay time of 200–500 ns were the optimum conditions for the LIBS application in tungsten impurity of tokamak wall diagnosis. Moreover, the ablation-depth results indicated that the depth-resolution of fusion-related material analysis can be controlled by the ambient gas pressure. Temporally-resolved emission measurements were carried out to further investigate the continuum radiation and ionic and atomic emission behaviors. The temporal evolution of the electron density and electron temperature at different pressures was also determined. The plasma parameter change and laser ablation depth reduction were observed which are attributed to the ambient gas confinement and enhanced plasma shielding.

1 February 2014 in Plasma Science and Technology
Verified
Journal Article
Closed access
DZDongye Zhao
Dongye Zhao
NFNazar Farid
Nazar Farid
RHRan Hai
Ran Hai
DWDing Wu
Ding Wu
HDHongbin Ding
Hongbin Ding

12 October 2020 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Closed access
PDF file
DZDongye Zhao
Dongye Zhao
DWDing Wu
Ding Wu
JOJannis Oelmann
Jannis Oelmann
SBSebastijan Brezinsek
Sebastijan Brezinsek
QXQingmei Xiao
Qingmei Xiao
HDHongbin Ding
Hongbin Ding
The objective of the present study has been to evaluate the potential applications of picosecond laser-induced breakdown spectroscopy (ps-LIBS) in nuclear fusion devices. The laser-ablation behaviors and the spectral emission features of ps-LIBS at broad laser fluences have been investigated under a high vacuum using a 35 ps laser with λ = 355 nm in order to achieve high depth-resolution diagnosis of the key fusion-related material, tungsten (W). For the ablation behaviors, three ablation regimes in laser fluences have been clearly identified, both in terms of average ablation rate (AAR) changes and surface morphology variations. For the spectral emission features of ps-LIBS investigated utilizing CCD and ICCD spectrometers, the intensities of the continuum background and atomic lines emission showed the different rising tendencies with the laser fluence in these three ablation regimes. Three representative craters in the three ablation regimes were characterized by scanning electron microscopy (SEM) to investigate the crater morphologies and microstructures. The results for the ablation rates and spectral emission features as well as the crater morphologies suggest that the first ablation regime was a superior choice for the diagnosis of the W wall by ps-LIBS due to the limited AAR (<40 nm per pulse), the small thermal effect, and thus the potentially high depth-resolution capacity. Further, the AARs and spectral emission features of ps-LIBS as a function of the ablation crater diameter in the first ablation regime were systematically studied. The results demonstrate that the AAR was weakly dependent on the crater diameter when keeping the same laser fluence, while the spectral intensities of the ps-LIBS increased significantly with the crater diameter increasing. Moreover, a rectangle-like cross-section of the crater could be achieved in the first ablation regime. This has a unique benefit for depth analysis of the deposited layer on the first wall of nuclear fusion devices by ps-LIBS.