Maria Chiara Martire

Maria Chiara Martire

Auto-generated profile, based on publicly available information

Maria Chiara Martire

Biophysics, GSI Helmholtz Centre for Heavy Ion Research GmbH, Planckstr. 1, Darmstadt, Hessen, 64291, GERMANY

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 September 2024 in Physics in Medicine & Biology
Verified
Journal Article
Open access
LVLennart Volz
Lennart Volz
JKJames Korte
James Korte
MMMaria Chiara Martire
Maria Chiara Martire
YZYe Zhang
Ye Zhang
NHNicholas Hardcastle
Nicholas Hardcastle
CGChristian Graeff
Christian Graeff
Objective. Upright positioning has seen a surge in interest as a means to reduce radiotherapy (RT) cost, improve patient comfort, and, in selected cases, benefit treatment quality. In particle therapy (PT) in particular, eliminating the need for a gantry can present massive cost and facility footprint reduction. This review discusses the opportunities of upright RT in perspective of the open challenges. Approach. The clinical, technical, and workflow challenges that come with the upright posture have been extracted from an extensive literature review, and the current state of the art was collected in a synergistic perspective from photon and particle therapy. Considerations on future developments and opportunities are provided. Main results. Modern image guidance is paramount to upright RT, but it is not clear which modalities are essential to acquire in upright posture. Using upright MRI or upright CT, anatomical differences between upright/recumbent postures have been observed for nearly all body sites. Patient alignment similar to recumbent positioning was achieved in small patient/volunteer cohorts with prototype upright positioning systems. Possible clinical advantages, such as reduced breathing motion in upright position, have been reported, but limited cohort sizes prevent resilient conclusions on the treatment impact. Redesign of RT equipment for upright positioning, such as immobilization accessories for various body regions, is necessary, where several innovations were recently presented. Few clinical studies in upright PT have already reported promising outcomes for head&neck patients. Significance. With more evidence for benefits of upright RT emerging, several centers worldwide, particularly in PT, are installing upright positioning devices or have commenced upright treatment. Still, many challenges and open questions remain to be addressed to embed upright positioning firmly in the modern RT landscape. Guidelines, professionals trained in upright patient positioning, and large-scale clinical studies are required to bring upright RT to fruition.

30 September 2024 in Physics in Medicine & Biology
Verified
Journal Article
Open access
CGC Galeone
C Galeone
TST Steinsberger
T Steinsberger
MDM Donetti
M Donetti
MMM C Martire
M C Martire
FMF M Milian
F M Milian
CGChristian Graeff
Christian Graeff
Objective. Real-time adaptive particle therapy is being investigated as a means to maximize the treatment delivery accuracy. To react to dosimetric errors, a system for fast and reliable verification of the agreement between planned and delivered doses is essential. This study presents a clinically feasible, real-time 4D-dose reconstruction system, synchronized with the treatment delivery and motion of the patient, which can provide the necessary feedback on the quality of the delivery. Approach. A GPU-based analytical dose engine capable of millisecond dose calculation for carbon ion therapy has been developed and interfaced with the next generation of the dose delivery system (DDS) in use at Centro Nazionale di Adroterapia Oncologica (CNAO). The system receives the spot parameters and the motion information of the patient during the treatment and performs the reconstruction of the planned and delivered 4D-doses. After each iso-energy layer, the results are displayed on a graphical user interface by the end of the spill pause of the synchrotron, permitting verification against the reference dose. The framework has been verified experimentally at CNAO for a lung cancer case based on a virtual phantom 4DCT. The patient’s motion was mimicked by a moving Ionization Chamber (IC) 2D-array. Main results. For the investigated static and 4D-optimized treatment delivery cases, real-time dose reconstruction was achieved with an average pencil beam dose calculation speed up to more than one order of magnitude smaller than the spot delivery. The reconstructed doses have been benchmarked against offline log-file based dose reconstruction with the TRiP98 treatment planning system, as well as QA measurements with the IC 2D-array, where an average gamma-index passing rate (3%/3 mm) of 99.8% and 98.3%, respectively, were achieved. Significance. This work provides the first real-time 4D-dose reconstruction engine for carbon ion therapy. The framework integration with the CNAO DDS paves the way for a swift transition to the clinics.

29 July 2025 in Physics in Medicine & Biology
Verified
Journal Article
Open access
CGCosimo Galeone
Cosimo Galeone
ANAnestis Nakas
Anestis Nakas
MDMarco Donetti
Marco Donetti
MMMaria Chiara Martire
Maria Chiara Martire
FMFelix Mas Milian
Felix Mas Milian
CGChristian Graeff
Christian Graeff
Objective: Irregular motion impacts treatment accuracy and can be compensated by larger margins or online adaptive approaches. A seamless workflow for fast and accurate 4D-dose reconstruction allows dosimetric monitoring intra- and inter-fractionally, as a basis for adaptive therapy. This study presents a real-time, motion-adaptive framework that combines motion modeling and treatment verification, integrated into the dose delivery and monitoring systems to enable continuous assessment of the delivered 4D-dose. Approach: The framework includes a GPU-based analytical algorithm for real-time dose reconstruction in carbon ion therapy, interfaced with the Dose Delivery and Optical Tracking Systems at the Centro Nazionale di Adroterapia Oncologica (CNAO). A motion model, driven by external surrogate tracking, generates a virtual CT every 150 ms, used for 4D-dose reconstruction with measured spot parameters. Planned and delivered doses are compared after each iso-energy slice. The framework was validated at CNAO using a geometric target and a 4D lung tumor phantom with a moving 2D ionization chamber array, under regular and irregular motion patterns. Main results: The framework successfully generated real-time CT images of the lung phantom, showing strong agreement with ground-truth images. Dose reconstructions were performed within inter-spill times during delivery, ensuring rapid assessment. Comparisons against detector measurements yielded an average gamma-index passing rate of 99% (3%/3mm), confirming the accuracy of both the motion model and the integrated treatment verification system. Significance: This work presents the first real-time framework for carbon ion therapy, integrating motion modeling and dose reconstruction to handle irregular motion, fully embedded in a clinic-like setup.

3 March 2025 in Physics in Medicine & Biology
Verified
Journal Article
Open access
TSTimo Steinsberger
Timo Steinsberger
ANAnestis Nakas
Anestis Nakas
AVAlessandro Vai
Alessandro Vai
SMSilvia Molinelli
Silvia Molinelli
MDMarco Donetti
Marco Donetti
CGChristian Graeff
Christian Graeff
Objective. To identify suitable combination strategies for treatment planning and beam delivery in scanned carbon ion therapy of moving tumors. Approach. Carbon ion treatment plans for five abdominal tumors were optimized on four-dimensional (4D) computed tomography (CT) data using the following approaches. 4DITV across all phases and within a gating window, single phase uniform dose, and an innovative 4D tracking internal target volume (ITV) strategy. Delivered single-fraction doses were calculated on time-resolved virtual CT images reconstructed from 2D cine-magnetic resonance imaging series, using a deformable image registration pipeline. Treatment plans were combined with various beam delivery techniques: three-dimensional (no motion mitigation), rescanning, gating, beam tracking, and multi-phase 4D delivery with and without residual tracking (MP4D and MP4DRT) to form in total 11 treatment modalities. Single fraction doses were accumulated to simulate a fractionated treatment. Main results. Breath-sampled treatments using the MP4D and MP4DRT delivery techniques were the only to achieve D 95 > 95% for hypofractionated treatments, with little dependence on the number of fractions. A combination of MP4DRT with the new 4D tracking ITV approach resulting in conformal dose distributions and demonstrated the greatest robustness against irregular motion and anatomical changes. Significance. This study demonstrates, that real-time adaptive beam delivery strategies can deliver conformal doses within single fractions, thereby enabling hypofractionated treatment schemes that are not feasible with conventional strategies.

18 September 2026 in Radiotherapy and Oncology
Verified
Journal Article
Open access
PTPetra Trnkova
Petra Trnkova
TUTracy Underwood
Tracy Underwood
RBRasmus Bokrantz
Rasmus Bokrantz
EEErik Engwall
Erik Engwall
CGCarri Glide-Hurst
Carri Glide-Hurst
LVLennart Volz
Lennart Volz