Marco Donetti

Marco Donetti

Auto-generated profile, based on publicly available information

Marco Donetti

Centro Nazionale di Adroterapia Oncologica (CNAO), Pavia, Italy

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 February 2020 in IEEE Transactions on Radiation and Plasma Medical Sciences
Verified
Journal Article
Closed access
IMI. Mattei
I. Mattei
AAA. Alexandrov
A. Alexandrov
LSL. Alunni Solestizi
L. Alunni Solestizi
GAG. Ambrosi
G. Ambrosi
SAS. Argiro
S. Argiro
Alessio SartiAlessio Sarti
Alessio Sarti
In a carbon ion treatment the nuclear fragmentation of both target and beam projectiles impacts on the dose released on the tumour and on the surrounding healthy tissues. Carbon ion fragmentation occurring inside the patient body has to be studied in order to take into account this contribution. These data are also important for the development of the range monitoring techniques with charged particles. The production of charged fragments generated by carbon ion beams of 115-353 MeV/u kinetic energy impinging on carbon, oxygen and hydrogen targets has been measured at the CNAO particle therapy center (Pavia, Italy). The use of thin targets of graphite (C), PMMA (C2O5H8) and polyvinyl-toluene (plastic scintillator, CbHa) allowed to measure fragments production cross sections, exploiting a Time of Flight (ToF) technique. Plastic scintillator detectors have been used to perform the ToF measurements, while LYSO crystals have been used for the deposited energy measurement and to perform particle identification. Cross sections have been measured at 90 and 60 degrees with respect to the beam direction. The measured proton, deuteron and triton differential production cross sections on C, O and H, obtained exploiting the target subtraction strategy, are presented here as a function of the fragment kinetic energy.

9 November 2022 in Medical Physics
Verified
Journal Article
Open access
Giuseppe MagroGiuseppe Magro
Giuseppe Magro
MFMartina Fassi
Martina Fassi
AMALFREDO MIRANDOLA
ALFREDO MIRANDOLA
EREleonora Rossi
Eleonora Rossi
SMSilvia Molinelli
Silvia Molinelli
AMAndrea Mairani
Andrea Mairani
Background: With rapid evolutions of fast and sophisticated calculation techniques and delivery technologies, clinics are almost facing a daily patient‐specific (PS) plan adaptation, which would make a conventional experimental quality assurance (QA) workflow unlikely to be routinely feasible. Therefore, in silico approaches are foreseen by means of second‐check independent dose calculation systems possibly handling machine log‐files.Purpose: To validate the in‐house developed GPU‐dose engine, FRoG, for light ion beam therapy (protons and carbon ions) as a second‐check independent calculation system and to integrate machine log‐file analysis into the patient‐specific quality assurance (PSQA) program.Methods: Spot sizes, depth‐dose distributions, and absolute dose calibrations were configured into FRoG and a set of nine regular‐shaped targets in combination with more than 170 clinical treatment fields were tested against pinpoint ionization chamber measurements. Both the treatment planning system DICOM RTplans and machine treatment log‐files were used as input for the dose kernel in water, and a 3D local γ (1 mm/2%) index was used as the main evaluation metric.Results: Calculated configuration data matched experimental measurements with submillimetric agreement. For regular‐shaped targets, the unsigned average relative difference between calculated and measured dose values was less than 2% for both protons and carbon ions. The mean γ passing rate (PR) was around 98% for both particle species. For clinical treatment beams, DICOM‐based recalculations showed a γ‐PR more than 99% for both particle species. The same level of agreement was preserved for protons when moving to log‐file‐based recalculations. A score of around 95% was registered for carbon ion beams, once excluding low‐quality machine log‐files. Unsigned average relative difference against acquired data was less than 2% also for real clinical beams.Conclusions: FRoG was proven as an accurate and reliable tool for PSQA in scanning light ion beam therapy. The proposed method allows for an extremely efficient workflow, without compromising the quality of the plan verification procedure.

1 June 2021 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
AKA.C. Kraan
A.C. Kraan
RZRoberto Zarrella
Roberto Zarrella
AAAndrey Alexandrov
Andrey Alexandrov
BAB. Alpat
B. Alpat
GAG. Ambrosi
G. Ambrosi
MBM.G. Bisogni
M.G. Bisogni

3 August 2024 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Open access
EDEmanuele Maria Data
Emanuele Maria Data
FMFelix Mas Milian
Felix Mas Milian
MAM. Abujami
M. Abujami
DBD. Bersani
D. Bersani
PCP. Cerello
P. Cerello
Simona GiordanengoSimona Giordanengo
Simona Giordanengo

29 November 2023 in Physics in Medicine & Biology
Verified
Journal Article
Open access
VMVincenzo Monaco
Vincenzo Monaco
OAOmar Hammad Ali
Omar Hammad Ali
DBDavide Bersani
Davide Bersani
MAMohammed Abujami
Mohammed Abujami
MBMaurizio Boscardin
Maurizio Boscardin
Roberto SacchiRoberto Sacchi
Roberto Sacchi
Objective . The performance of silicon detectors with moderate internal gain, named low-gain avalanche diodes (LGADs), was studied to investigate their capability to discriminate and count single beam particles at high fluxes, in view of future applications for beam characterization and on-line beam monitoring in proton therapy. Approach . Dedicated LGAD detectors with an active thickness of 55 μ m and segmented in 2 mm 2 strips were characterized at two Italian proton-therapy facilities, CNAO in Pavia and the Proton Therapy Center of Trento, with proton beams provided by a synchrotron and a cyclotron, respectively. Signals from single beam particles were discriminated against a threshold and counted. The number of proton pulses for fixed energies and different particle fluxes was compared with the charge collected by a compact ionization chamber, to infer the input particle rates. Main results . The counting inefficiency due to the overlap of nearby signals was less than 1% up to particle rates in one strip of 1 MHz, corresponding to a mean fluence rate on the strip of about 5 × 10 7 p/(cm 2 ·s). Count-loss correction algorithms based on the logic combination of signals from two neighboring strips allow to extend the maximum counting rate by one order of magnitude. The same algorithms give additional information on the fine time structure of the beam. Significance . The direct counting of the number of beam protons with segmented silicon detectors allows to overcome some limitations of gas detectors typically employed for beam characterization and beam monitoring in particle therapy, providing faster response times, higher sensitivity, and independence of the counts from the particle energy.

30 September 2024 in Physics in Medicine & Biology
Verified
Journal Article
Open access
CGC Galeone
C Galeone
TST Steinsberger
T Steinsberger
MDM Donetti
M Donetti
MMM C Martire
M C Martire
FMF M Milian
F M Milian
CGChristian Graeff
Christian Graeff
Objective. Real-time adaptive particle therapy is being investigated as a means to maximize the treatment delivery accuracy. To react to dosimetric errors, a system for fast and reliable verification of the agreement between planned and delivered doses is essential. This study presents a clinically feasible, real-time 4D-dose reconstruction system, synchronized with the treatment delivery and motion of the patient, which can provide the necessary feedback on the quality of the delivery. Approach. A GPU-based analytical dose engine capable of millisecond dose calculation for carbon ion therapy has been developed and interfaced with the next generation of the dose delivery system (DDS) in use at Centro Nazionale di Adroterapia Oncologica (CNAO). The system receives the spot parameters and the motion information of the patient during the treatment and performs the reconstruction of the planned and delivered 4D-doses. After each iso-energy layer, the results are displayed on a graphical user interface by the end of the spill pause of the synchrotron, permitting verification against the reference dose. The framework has been verified experimentally at CNAO for a lung cancer case based on a virtual phantom 4DCT. The patient’s motion was mimicked by a moving Ionization Chamber (IC) 2D-array. Main results. For the investigated static and 4D-optimized treatment delivery cases, real-time dose reconstruction was achieved with an average pencil beam dose calculation speed up to more than one order of magnitude smaller than the spot delivery. The reconstructed doses have been benchmarked against offline log-file based dose reconstruction with the TRiP98 treatment planning system, as well as QA measurements with the IC 2D-array, where an average gamma-index passing rate (3%/3 mm) of 99.8% and 98.3%, respectively, were achieved. Significance. This work provides the first real-time 4D-dose reconstruction engine for carbon ion therapy. The framework integration with the CNAO DDS paves the way for a swift transition to the clinics.