Solid-state transformers (SSTs) are an emerging technology that has been developed to improve the stability, reliability, and economic operation of distribution systems. These new transformers are composed of a medium ac voltage (MV) stage, a dc stage, and a low ac voltage (LV) stage. Passive and active dc-links are used to construct the dc stage in SSTs in order offer new functionalities, including hybrid (ac and dc) distribution, reactive power compensation, voltage/frequency regulation, power quality improvement, and distributed generation utilization. On one hand, a distribution SST has its ac stage connected to a MV level, which mandates specific power electronic converter (PEC) topologies, switching element capabilities, and filtering circuits. On the other hand, the dc-link stage has to provide isolation between the MV and LV levels, which requires the employment of isolated dc PECs. Part I of this work provides a review of SST designs and constructions (for deployment in distribution systems), in terms of the required technology, supported functionalities, and construction features.
28 August 2019 in IEEE Transactions on Industry Applications
Solid-state transformers (SSTs) have diverse designs and constructions that make them suitable for various industrial applications, including distributions systems. This new breed of transformers has been developed to support the typical functionals of core-type distribution transformers, along with new functionalities, such as controlling power flows, integrating dc distribution systems, utilizing distributed generation and storage units, supporting load-side voltage/frequency control, and improving the power quality. As SSTs become candidates for distribution systems, their deployment can pose challenges for distribution systems. Such challenges include the cost, protection, size and weight, efficiency, and adequate grounding designs. This paper presents and discusses challenges that can face the deployment of SSTs in distribution systems. Furthermore, this paper provides a comparison between core-type and SST transformers, when deployed in distribution systems.
17 October 2018 in IEEE Transactions on Industrial Electronics
Induction motors (IMs) are among the maturest electro-mechanical technologies still in use today. Over the course of the last century, their structure, control, and operation have been through several stages of development. Among stages of development, the automated control and continuous monitoring of IMs has benefited from the emergence of modern artificial intelligence (AI) methods. IM automation schemes have demonstrated the ability to provide machine fault detection and diagnosis (FDD) function. AI based FDD methods in IMs have employed frequency-domain, time-frequency, and time-domain analysis as the basis of their feature extraction schemes. A promising feature extraction scheme is one that uses symmetrical components (SCs) in time-domain FDD systems. Current SC based approaches, however, are limited in their generalizability to different fault classes, may require detailed machine models, and can suffer from computational limitations. In this proposed work, an improved feature extraction method that uses SCs for a pattern recognition based FDD scheme for three-phase (3°) IMs will be presented. This novel feature extraction method will be implemented and verified experimentally to demonstrate high classification performance, increased generalizability, and low computational cost.
10 October 2019 in IEEE Transactions on Industry Applications
Three phase ( $3\phi$ ) power transformers can have their windings configured to create local neutral points that can be grounded. The grounding of a $3\phi$ power transformer is designed to limit ground fault currents and maintain low ground potentials. These constraints can be translated into a resistive grounding that is usually designed based on the system ratings and parameters. The resistive grounding, however, can impact the flow of the harmonic components present in the exciting currents. As a result, undesired harmonic components are induced in primary and secondary voltages. This paper presents the design and performance of a frequency-selective grounding that can meet the constraints for grounding a $3\phi$ power transformer. The developed grounding is designed to provide a resistive path for low frequency currents (faults), while providing a low impedance path for high frequency currents (harmonics). The frequency-selective grounding is experimentally tested for a $3\phi$ power transformer with different primary and secondary winding configurations, different fault types, and source grounding. Test results show that the developed grounding can reduce the ground potential, harmonic distortion in primary and secondary voltages, and ground fault currents with a minimum interference with ground fault protective devices.
7 February 2020 in IEEE Transactions on Industry Applications
This paper presents and tests the performance of a digital differential protection for three phase ( $3\phi$ ) converter transformers. The proposed digital differential protection is developed to comply with the ANSI 87T standard. The presented protection is featured with fault detection based on the energy contents of the high frequency sub-bands of the $d-q$ -axis components of differential currents. Desired energy contents are extracted using the phaselet transform (PHT), which can process signals without sensitivity to the variations in their phase shifts. Energy contents of the high frequency sub-bands offer accurate, fast, and reliable detection and identification of internal faults in any part of a $3\phi$ converter transformer. The $d-q$ PHT-based digital differential protection is implemented for performance evaluation using different $3\phi$ converter transformers, when feeding controlled rectifier units. Performance results demonstrate accurate, fast and reliable detection and response to different types of fault and non-fault events. Response features of the developed differential protection are complimented with simple implementation, reduced computations, and minor sensitivity to phase shifts, fault location, and loading levels.