Basma B. Hasanen

Basma B. Hasanen

Auto-generated profile, based on publicly available information

Basma B. Hasanen

Department of Mechanical Engineering and Khalifa University Center for Autonomous Robotic Systems (KUCARS), Khalifa University, Abu Dhabi, United Arab Emirates

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 October 2022
Verified
Conference Paper
Open access
BHBasma B. Hasanen
Basma B. Hasanen
MAMohammad Awad
Mohammad Awad
MBMohamed N. Boushaki
Mohamed N. Boushaki
ZNZhenwei Niu
Zhenwei Niu
MRMohamed Ramadan
Mohamed Ramadan
IHIrfan Hussain
Irfan Hussain
Loss of upper extremity motor control and function is an unremitting symptom in post-stroke patients. This would impose hardships on accomplishing their daily life activities. Supernumerary robotic limbs (SRLs) were introduced as a solution to regain the lost Degrees of Freedom (DoFs) by introducing an independent new limb. The actuation systems in SRL can be categorized into rigid and soft actuators. Soft actuators have proven advantageous over their rigid counterparts through intrinsic safety, cost, and energy efficiency. However, they suffer from low stiffness, which jeopardizes their accuracy. Variable Stiffness Actuators (VSAs) are newly developed technologies that have been proven to ensure accuracy and safety. In this paper, we introduce the novel Supernumerary Robotic Limb based on Variable Stiffness Actuators. Based on our knowledge, the proposed proof-of-concept SRL is the first that utilizes Variable Stiffness Actuators. The developed SRL would assist post-stroke patients in bi-manual tasks, e.g., eating with a fork and knife. The modeling, design, and realization of the system are illustrated. The proposed SRL was evaluated and verified for its accuracy via predefined trajectories. The safety was verified by utilizing the momentum observer for collision detection, and several post-collision reaction strategies were evaluated through the Soft Tissue Injury Test. The assistance process is qualitatively verified through standard user-satisfaction questionnaire.

11 July 2024 in IEEE Sensors Journal
Verified
Journal Article
Closed access
BHBasma Hasanen
Basma Hasanen
Bhivraj SutharBhivraj Suthar
Bhivraj Suthar
YZYahya Zweiri
Yahya Zweiri
LSLakmal Seneviratne
Lakmal Seneviratne
IHIrfan Hussain
Irfan Hussain
Supernumerary Robotic Limbs (SRLs) have become an effective method for assisting post-stroke patients in their daily life activities. However, conventional SRLs are constrained by functionality, wearability, and portability limitations, which are attributed to the presence of bulky robot actuators, gears, complex design, and high power consumption. This paper presents twisted string actuated (TSAs) flexure robot joints (FRJs) for a supernumerary robotic arm (SRA). This design aims for a compact, lightweight, energy-efficient, affordable, wearable, and portable SRL. The Twisted string actuation replaces the bulky actuator and gearbox in the robot joint. The FRJ joint design and modelling is proposed for the TSA-actuated Flexure Robot Joint (FRJ) and verified through experimental validation. A prototype of the 3 Degrees of Freedom SRL was developed, weighing 2.5 kilograms and possessing a payload capacity of 0.15 kilograms. The TSA-driven FRJ can produce 3 Nm joint torque at the cost of 32.5 mNm maximum motor torque, and the full SRL’s power consumption is 40 watts. In addition, a demonstration of bi-manual tasks is presented using the proposed SRL to check its feasibility. Furthermore, the proposed SRL has merits compared with the existing SRLs in the literature.