Yanting Cheng

Yanting Cheng

Auto-generated profile, based on publicly available information

Yanting Cheng

Department of Electric Power Engineering, South China University of Technology, Guangzhou, China

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2022 in Engineering Failure Analysis
Verified
Journal Article
Closed access
YCYanting Cheng
Yanting Cheng
YHYanpeng Hao
Yanpeng Hao
YCYun Chen
Yun Chen
BHBaojun Hui
Baojun Hui
MFMingli Fu
Mingli Fu
LLLicheng Li
Licheng Li

30 November 2023 in IEEE Sensors Journal
Verified
Journal Article
Closed access
YCYanting Cheng
Yanting Cheng
Yanpeng HaoYanpeng Hao
Yanpeng Hao
QLQishun Li
Qishun Li
BHBaojun Hui
Baojun Hui
WTWanxing Tian
Wanxing Tian
LLLicheng Li
Licheng Li
In recent years, the water blocking tape in high-voltage (HV) crosslinked polyethylene (XLPE) cable is suffered from penetrating moisture frequently, which affects its safe and stable operation, while there are no effective detection methods yet. In this paper, a 110 kV cable sample was prepared, with a single-mode fiber of 30 m built in it. Meanwhile, a distributed detection system for built-in optical fiber of 110 kV cable was established and the criterion for BOTDR breakpoint detection method was proposed. The comparison test of breakpoint detection methods for built-in optical fiber was carried out using Brillouin optical time domain reflectometry (BOTDR) and optical time domain reflectometry (OTDR). Besides, detection tests of moisture water blocking tape including its drying process were launched using BOTDR. The relationship of Brillouin frequency shift (BFS) with moisture length, position, and drying process of the tape was studied. The results have demonstrated that BOTDR plays a better role in detecting breakpoint with poor-quality end face than OTDR. By using BOTDR to detect moisture tape in cable, the BFS decreases sharply when moisture length over some thresholds and linearly falls with increasing moisture length. As time passes, the BFS gradually increases, which can characterize drying process.

22 January 2024 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
YCYanting Cheng
Yanting Cheng
Yanpeng HaoYanpeng Hao
Yanpeng Hao
PZPeng Zhao
Peng Zhao
WTWanxing Tian
Wanxing Tian
HTHaotian Tan
Haotian Tan
LLLicheng Li
Licheng Li
Temperature sensitivity coefficient of optical fiber is a critical parameter for distributed temperature measurement based on Brillouin scattering. However, the optical fiber required by traditional coefficient measurement method, is so long that it is not suitable for embedded optical fiber in high-voltage (HV) cross-linked polyethylene (XLPE) power cables. In this paper, a measuring system for temperature sensitivity coefficient of distributed Brillouin scattering optical fiber is established. By modulating the temperature of a short section of optical fiber to be remarkably differ from that of remaining optical fiber within the spatial resolution of sensing system, the coefficient can be obtained through measuring the Brillouin frequency shift (BFS) of the modulated peak in Brillouin gain spectrum (BGS). The results show that using Brillouin optical time domain reflectometer (BOTDR) with a spatial resolution of 10 m, the coefficient obtained by optical fiber longer than 0.5 m is the same as that obtained by 10 m optical fiber. As the phenomenon that the temperature sensitivity coefficient of polyvinyl chloride (PVC) jacketed optical fiber in the water blocking tape and power cable are both 1.4 MHz/°C, the embedded optical fiber in tape can be used to replace that in HV XLPE cable to measure the coefficient.

19 January 2024 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
YCYanting Cheng
Yanting Cheng
Yanpeng HaoYanpeng Hao
Yanpeng Hao
WTWanxing Tian
Wanxing Tian
PZPeng Zhao
Peng Zhao
HTHaotian Tan
Haotian Tan
LLLicheng Li
Licheng Li
In recent years, buffer layer defects have occur in high-voltage (HV) crosslinked polyethylene (XLPE) cable frequently, which affects its safe and stable operation, while there are no effective detection methods yet. In this paper, a 110 kV cable sample was prepared, embedded with single-mode optical fiber. Meanwhile, a distributed optical fiber detection system for buffer layer defects based on Brillouin optical time domain reflectometry (BOTDR) was built. The partial discharge (PD) test and BOTDR detection test for defective cable were conducted to study the relationship between Brillouin frequency shift (BFS) variation of built-in fiber and temperature rise resulting from dielectric loss, white powder, and damaged insulation. During applying voltage of 96 kV for 7 hours, the BFS variations within white powder and damaged insulation defects are significantly larger than that within non-defect which is only determined by dielectric loss. The BFS variations are closely related to the number and depth of damaged insulation holes, as well as circumferential angle of holes against optical fiber. But the BFS variations within moisture water blocking tape, poor electrical connection, and damaged insulation screen cannot be distinguished from that within non-defect.