Stefan Posse

Stefan Posse

Auto-generated profile, based on publicly available information

Stefan Posse

Department of Neurology, University of New Mexico School of Medicine, Albuquerque, New Mexico, USA

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 November 2012 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Closed access
PDF file
SPStefan Posse
Stefan Posse
RORicardo Otazo
Ricardo Otazo
SDStephen R. Dager
Stephen R. Dager
JAJeffry Alger
Jeffry Alger

29 April 2020 in NMR in Biomedicine
Verified
Journal Article
Closed access
PDF file
AMAndrew A. Maudsley
Andrew A. Maudsley
OAOvidiu C. Andronesi
Ovidiu C. Andronesi
PBPeter B. Barker
Peter B. Barker
ABAlberto Bizzi
Alberto Bizzi
Wolfgang BognerWolfgang Bogner
Wolfgang Bogner
BSBrian J. Soher
Brian J. Soher

17 August 2020 in NMR in Biomedicine
Verified
Journal Article
Open access
PDF file
RKRoland Kreis
Roland Kreis
VBVincent Boer
Vincent Boer
ICIn‐Young Choi
In‐Young Choi
CCCristina Cudalbu
Cristina Cudalbu
RGRobin A. de Graaf
Robin A. de Graaf
Wolfgang BognerWolfgang Bogner
Wolfgang Bogner
With a 40‐year history of use for in vivo studies, the terminology used to describe the methodology and results of magnetic resonance spectroscopy (MRS) has grown substantially and is not consistent in many aspects. Given the platform offered by this special issue on advanced MRS methodology, the authors decided to describe many of the implicated terms, to pinpoint differences in their meanings and to suggest specific uses or definitions. This work covers terms used to describe all aspects of MRS, starting from the description of the MR signal and its theoretical basis to acquisition methods, processing and to quantification procedures, as well as terms involved in describing results, for example, those used with regard to aspects of quality, reproducibility or indications of error. The descriptions of the meanings of such terms emerge from the descriptions of the basic concepts involved in MRS methods and examinations. This paper also includes specific suggestions for future use of terms where multiple conventions have emerged or coexisted in the past.

3 July 2007 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
SPStefan Posse
Stefan Posse
RORicardo Otazo
Ricardo Otazo
ACArvind Caprihan
Arvind Caprihan
JBJuan Bustillo
Juan Bustillo
HCHongji Chen
Hongji Chen
JAJeffry R. Alger
Jeffry R. Alger
In this multicenter study, 2D spatial mapping of J‐coupled resonances at 3T and 4T was performed using short‐TE (15 ms) proton echo‐planar spectroscopic imaging (PEPSI). Water‐suppressed (WS) data were acquired in 8.5 min with 1‐cm3 spatial resolution from a supraventricular axial slice. Optimized outer volume suppression (OVS) enabled mapping in close proximity to peripheral scalp regions. Constrained spectral fitting in reference to a non‐WS (NWS) scan was performed with LCModel using correction for relaxation attenuation and partial‐volume effects. The concentrations of total choline (tCho), creatine + phosphocreatine (Cr+PCr), glutamate (Glu), glutamate + glutamine (Glu+Gln), myo‐inositol (Ins), NAA, NAA+NAAG, and two macromolecular resonances at 0.9 and 2.0 ppm were mapped with mean Cramer‐Rao lower bounds (CRLBs) between 6% and 18% and ∼150‐cm3 sensitive volumes. Aspartate, GABA, glutamine (Gln), glutathione (GSH), phosphoethanolamine (PE), and macromolecules (MMs) at 1.2 ppm were also mapped, although with larger mean CRLBs between 30% and 44%. The CRLBs at 4T were 19% lower on average as compared to 3T, consistent with a higher signal‐to‐noise ratio (SNR) and increased spectral resolution. Metabolite concentrations were in the ranges reported in previous studies. Glu concentration was significantly higher in gray matter (GM) compared to white matter (WM), as anticipated. The short acquisition time makes this methodology suitable for clinical studies. Magn Reson Med, 2007.

1 May 2012 in NeuroImage
Verified
Journal Article
Closed access
SPStefan Posse
Stefan Posse
EAElena Ackley
Elena Ackley
RMRadu Mutihac
Radu Mutihac
JRJochen Rick
Jochen Rick
MSMatthew Shane
Matthew Shane
OSOliver Speck
Oliver Speck

1 January 2013 in Frontiers in Human Neuroscience
Verified
Journal Article
Open access
SPStefan Posse
Stefan Posse
EAElena Ackley
Elena Ackley
RMRadu Mutihac
Radu Mutihac
TZTongsheng Zhang
Tongsheng Zhang
RHRuslan Hummatov
Ruslan Hummatov
HYHoward Yonas
Howard Yonas
We recently demonstrated that ultra-high-speed real-time fMRI using multi-slab echo-volumar imaging (MEVI) significantly increases sensitivity for mapping task-related activation and resting-state networks (RSNs) compared to echo-planar imaging (Posse et al., 2012). In the present study we characterize the sensitivity of MEVI for mapping RSN connectivity dynamics, comparing independent component analysis (ICA) and a novel seed-based connectivity analysis (SBCA) that combines sliding-window correlation analysis with meta-statistics. This SBCA approach is shown to minimize the effects of confounds, such as movement, and CSF and white matter signal changes, and enables real-time monitoring of RSN dynamics at time scales of tens of seconds. We demonstrate highly sensitive mapping of eloquent cortex in the vicinity of brain tumors and arterio-venous malformations, and detection of abnormal resting-state connectivity in epilepsy. In patients with motor impairment, resting-state fMRI provided focal localization of sensorimotor cortex compared with more diffuse activation in task-based fMRI. The fast acquisition speed of MEVI enabled segregation of cardiac-related signal pulsation using ICA, which revealed distinct regional differences in pulsation amplitude and waveform, elevated signal pulsation in patients with arterio-venous malformations and a trend toward reduced pulsatility in gray matter of patients compared with healthy controls. Mapping cardiac pulsation in cortical gray matter may carry important functional information that distinguishes healthy from diseased tissue vasculature. This novel fMRI methodology is particularly promising for mapping eloquent cortex in patients with neurological disease, having variable degree of cooperation in task-based fMRI. In conclusion, ultra-high-real-time speed fMRI enhances the sensitivity of mapping the dynamics of resting-state connectivity and cerebro-vascular pulsatility for clinical and neuroscience research applications.