Rodolphe Le Targat

Rodolphe Le Targat

Auto-generated profile, based on publicly available information

Rodolphe Le Targat

LNE-SYRTE

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 August 2011 in Science
Verified
Journal Article
Closed access
PDF file
JSJ. Struck
J. Struck
CÖC. Ölschläger
C. Ölschläger
RTR. Le Targat
R. Le Targat
PSP. Soltan-Panahi
P. Soltan-Panahi
AEA. Eckardt
A. Eckardt
KSK. Sengstock
K. Sengstock
An optical lattice of trapped atoms provides a tractable and tunable setup to study complex magnetic interactions.

9 August 2016 in Nature Communications
Verified
Journal Article
Open access
PDF file
CLC. Lisdat
C. Lisdat
GGG. Grosche
G. Grosche
NQN. Quintin
N. Quintin
CSC. Shi
C. Shi
SRS.M.F. Raupach
S.M.F. Raupach
PPP.-E. Pottie
P.-E. Pottie
Leveraging the unrivalled performance of optical clocks as key tools for geo-science, for astronomy and for fundamental physics beyond the standard model requires comparing the frequency of distant optical clocks faithfully. Here, we report on the comparison and agreement of two strontium optical clocks at an uncertainty of 5 × 10−17 via a newly established phase-coherent frequency link connecting Paris and Braunschweig using 1,415 km of telecom fibre. The remote comparison is limited only by the instability and uncertainty of the strontium lattice clocks themselves, with negligible contributions from the optical frequency transfer. A fractional precision of 3 × 10−17 is reached after only 1,000 s averaging time, which is already 10 times better and more than four orders of magnitude faster than any previous long-distance clock comparison. The capability of performing high resolution international clock comparisons paves the way for a redefinition of the unit of time and an all-optical dissemination of the SI-second.

9 April 2008 in Physical Review Letters
Verified
Journal Article
Closed access
PDF file
SBS. Blatt
S. Blatt
ALA. D. Ludlow
A. D. Ludlow
GCG. K. Campbell
G. K. Campbell
JTJ. W. Thomsen
J. W. Thomsen
TZT. Zelevinsky
T. Zelevinsky
VFV. V. Flambaum
V. V. Flambaum
The S01-P03 clock transition frequency νSr in neutral Sr87 has been measured relative to the Cs standard by three independent laboratories in Boulder, Paris, and Tokyo over the last three years. The agreement on the 1×10−15 level makes νSr the best agreed-upon optical atomic frequency. We combine periodic variations in the Sr87 clock frequency with Hg+199 and H-maser data to test local position invariance by obtaining the strongest limits to date on gravitational-coupling coefficients for the fine-structure constant α, electron-proton mass ratio μ, and light quark mass. Furthermore, after Hg+199, Yb+171, and H, we add Sr87 as the fourth optical atomic clock species to enhance constraints on yearly drifts of α and μ.

9 July 2013 in Nature Communications
Verified
Journal Article
Open access
PDF file
RTR. Le Targat
R. Le Targat
LLL. Lorini
L. Lorini
YCY. Le Coq
Y. Le Coq
MZM. Zawada
M. Zawada
JGJ. Guéna
J. Guéna
JLJ. Lodewyck
J. Lodewyck
Progress in realizing the SI second had multiple technological impacts and enabled further constraint of theoretical models in fundamental physics. Caesium microwave fountains, realizing best the second according to its current definition with a relative uncertainty of 2–4 × 10−16, have already been overtaken by atomic clocks referenced to an optical transition, which are both more stable and more accurate. Here we present an important step in the direction of a possible new definition of the second. Our system of five clocks connects with an unprecedented consistency the optical and the microwave worlds. For the first time, two state-of-the-art strontium optical lattice clocks are proven to agree within their accuracy budget, with a total uncertainty of 1.5 × 10−16. Their comparison with three independent caesium fountains shows a degree of accuracy now only limited by the best realizations of the microwave-defined second, at the level of 3.1 × 10−16.

2 June 2017 in Physical Review Letters
Verified
Journal Article
Closed access
PDF file
PDPacôme Delva
Pacôme Delva
JLJ. Lodewyck
J. Lodewyck
SBS. Bilicki
S. Bilicki
EBE. Bookjans
E. Bookjans
GVG. Vallet
G. Vallet
PGP. Gill
P. Gill
Phase compensated optical fiber links enable high accuracy atomic clocks separated by thousands of kilometers to be compared with unprecedented statistical resolution. By searching for a daily variation of the frequency difference between four strontium optical lattice clocks in different locations throughout Europe connected by such links, we improve upon previous tests of time dilation predicted by special relativity. We obtain a constraint on the Robertson-Mansouri-Sexl parameter |α|≲1.1×10−8, quantifying a violation of time dilation, thus improving by a factor of around 2 the best known constraint obtained with Ives-Stilwell type experiments, and by 2 orders of magnitude the best constraint obtained by comparing atomic clocks. This work is the first of a new generation of tests of fundamental physics using optical clocks and fiber links. As clocks improve, and as fiber links are routinely operated, we expect that the tests initiated in this Letter will improve by orders of magnitude in the near future.

7 December 2018 in Science Advances
Verified
Journal Article
Open access
PDF file
PWP. Wcisło
P. Wcisło
PAP. Ablewski
P. Ablewski
KBK. Beloy
K. Beloy
SBS. Bilicki
S. Bilicki
MBM. Bober
M. Bober
MZM. Zawada
M. Zawada
The first Earth-scale quantum sensor network based on optical atomic clocks is looking for dark matter candidates.