22 March 2011 in Physics in Medicine & Biology
In this study, a comprehensive electron dosimetry model of the adult male skeletal tissues is presented. The model is constructed using the University of Florida adult male hybrid phantom of Lee et al (2010 Phys. Med. Biol. 55 339-63) and the EGSnrc-based Paired Image Radiation Transport code of Shah et al (2005 J. Nucl. Med. 46 344-53). Target tissues include the active bone marrow, associated with radiogenic leukemia, and total shallow marrow, associated with radiogenic bone cancer. Monoenergetic electron emissions are considered over the energy range 1 keV to 10 MeV for the following sources: bone marrow (active and inactive), trabecular bone (surfaces and volumes), and cortical bone (surfaces and volumes). Specific absorbed fractions are computed according to the MIRD schema, and are given as skeletal-averaged values in the paper with site-specific values reported in both tabular and graphical format in an electronic annex available from http://stacks.iop.org/0031-9155/56/2309/mmedia. The distribution of cortical bone and spongiosa at the macroscopic dimensions of the phantom, as well as the distribution of trabecular bone and marrow tissues at the microscopic dimensions of the phantom, is imposed through detailed analyses of whole-body ex vivo CT images (1 mm resolution) and spongiosa-specific ex vivo microCT images (30 µm resolution), respectively, taken from a 40 year male cadaver. The method utilized in this work includes: (1) explicit accounting for changes in marrow self-dose with variations in marrow cellularity, (2) explicit accounting for electron escape from spongiosa, (3) explicit consideration of spongiosa cross-fire from cortical bone, and (4) explicit consideration of the ICRP's change in the surrogate tissue region defining the location of the osteoprogenitor cells (from a 10 µm endosteal layer covering the trabecular and cortical surfaces to a 50 µm shallow marrow layer covering trabecular and medullary cavity surfaces). Skeletal-averaged values of absorbed fraction in the present model are noted to be very compatible with those weighted by the skeletal tissue distributions found in the ICRP Publication 110 adult male and female voxel phantoms, but are in many cases incompatible with values used in current and widely implemented internal dosimetry software.
8 May 2016 in Journal of Applied Clinical Medical Physics
Benchmarking is a process in which standardized tests are used to assess system performance. The data produced in the process are important for comparative purposes, particularly when considering the implementation and quality assurance of DIR algorithms. In this work, five commercial DIR algorithms (MIM, Velocity, RayStation, Pinnacle, and Eclipse) were benchmarked using a set of 10 virtual phantoms. The phantoms were previously developed based on CT data collected from real head and neck patients. Each phantom includes a start of treatment CT dataset, an end of treatment CT dataset, and the ground‐truth deformation vector field (DVF) which links them together. These virtual phantoms were imported into the commercial systems and registered through a deformable process. The resulting DVFs were compared to the ground‐truth DVF to determine the target registration error (TRE) at every voxel within the image set. Real treatment plans were also recalculated on each end of treatment CT dataset and the dose transferred according to both the ground‐truth and test DVFs. Dosimetric changes were assessed, and TRE was correlated with changes in the DVH of individual structures. In the first part of the study, results show mean TRE on the order of 0.5 mm to 3 mm for all phantoms and ROIs. In certain instances, however, misregistrations were encountered which produced mean and max errors up to 6.8 mm and 22 mm, respectively. In the second part of the study, dosimetric error was found to be strongly correlated with TRE in the brainstem, but weakly correlated with TRE in the spinal cord. Several interesting cases were assessed which highlight the interplay between the direction and magnitude of TRE and the dose distribution, including the slope of dosimetric gradients and the distance to critical structures. This information can be used to help clinicians better implement and test their algorithms, and also understand the strengths and weaknesses of a dose adaptive approach.PACS number(s): 87.57.nj, 87.55.dk, 87.55.Qr
22 March 2011 in Physics in Medicine & Biology
A comprehensive set of photon fluence-to-dose response functions (DRFs) is presented for two radiosensitive skeletal tissues-active and total shallow marrow-within 15 and 32 bone sites, respectively, of the ICRP reference adult male. The functions were developed using fractional skeletal masses and associated electron-absorbed fractions as reported for the UF hybrid adult male phantom, which in turn is based upon micro-CT images of trabecular spongiosa taken from a 40 year male cadaver. The new DRFs expand upon both the original set of seven functions produced in 1985, and a 2007 update calculated under the assumption of secondary electron escape from spongiosa. In this study, it is assumed that photon irradiation of the skeleton will yield charged particle equilibrium across all spongiosa regions at energies exceeding 200 keV. Kerma coefficients for active marrow, inactive marrow, trabecular bone and spongiosa at higher energies are calculated using the DRF algorithm setting the electron-absorbed fraction for self-irradiation to unity. By comparing kerma coefficients and DRF functions, dose enhancement factors and mass energy-absorption coefficient (MEAC) ratios for active marrow to spongiosa were derived. These MEAC ratios compared well with those provided by the NIST Physical Reference Data Library (mean difference of 0.8%), and the dose enhancement factors for active marrow compared favorably with values calculated in the well-known study published by King and Spiers (1985 Br. J. Radiol. 58 345-56) (mean absolute difference of 1.9 percentage points). Additionally, dose enhancement factors for active marrow were shown to correlate well with the shallow marrow volume fraction (R(2) = 0.91). Dose enhancement factors for the total shallow marrow were also calculated for 32 bone sites representing the first such derivation for this target tissue.
19 September 2011 in Medical Physics
22 December 2010 in Journal of Magnetic Resonance Imaging
Purpose To determine the tracking factor by studying the relationship between kidney and diaphragm motions and to compare the efficiency of the gating‐and‐following and gating‐only algorithms in reducing motion artifacts in navigator‐gated scans. Materials and Methods Diaphragm and kidney motions were measured by using real‐time TrueFISP sequences from 10 healthy human volunteers to determine tracking factors at different acceptance windows. Mean tracking factors were used to calculate mean residual errors and improvement factors for the gating‐and‐following and gating‐only algorithms. Results Mean tracking factors for ±4, ±6, ±8 mm and full acceptance windows ranged from 0.6 to 0.7, with large interindividual variations. Acceptance rates increased as the size of the acceptance window increased (acceptance rate for a 4 mm window ∼50%). There was a greater reduction of motion errors by gating‐and‐following (maximum of 1.86 mm) than gating‐only (maximum of 7.05 mm). Conclusion Mean tracking factors obtained in this study can be used as a guideline for using the gating‐and‐following algorithm in navigator‐gated kidney scans. The gating‐and‐following and gating‐only algorithms were quantitatively compared, and it was found that the former is more effective in reducing motion errors. J. Magn. Reson. Imaging 2011;33:143–148.
17 November 2009 in Proceedings of the IEEE
Hybrid computational phantoms offer unique advantages for the construction of diverse anthropomorphic models. In this paper, a methodology is presented for the construction of patient-dependent phantoms built around anthropometric distributions of the U.S. adult and pediatric populations. The methodology relies on the flexibility of hybrid phantoms to match target anthropometric parameters as determined from National Center for Health Statistics databases. Target parameters as defined in this paper include the primary parameters such as standing height, sitting height, and total body mass; and secondary parameters such as waist, buttocks, arm, and thigh circumference. As a demonstration of this methodology, the UF hybrid adult male (UFHADM) and UF hybrid 10-year-old female (UFH10F) were selected as representative anchor phantoms for this study and were subsequently remodeled to create 25 different adult male and 15 different pediatric female patient-dependent phantoms. The phantoms were evaluated based on appearance and internal organ masses. Aesthetically, the phantoms appear correct and display characteristics of a diverse population including variability in body shape and standing/sitting height. Organ masses display several general trends, including a gradual increase with both standing height and subject weight. Selected organ masses from the UFHADM series were also compared with published correlations taken from a 2001 French-based autopsy study. The organ masses were located well within the statistical deviation presented in the autopsy study and followed similar trends when correlated with both standing height and body mass index.