The Federal University of Technology - Paraná (UTFPR), Civil Engineering Graduate Program, Deputado Heitor de Alencar Furtado St., 5000, Ecoville, 81280-340 Curitiba, Paraná, Brazil
Auto-generated profile, based on publicly available information
Mateus Xavier de Lima
The Federal University of Technology - Paraná (UTFPR), Civil Engineering Graduate Program, Deputado Heitor de Alencar Furtado St., 5000, Ecoville, 81280-340 Curitiba, Paraná, Brazil
The presence of silver in the natural water environment has been of great concern because of its toxicity, especially when it is in the free ion form (Ag+). This paper aims to study the adsorption kinetics of silver ions from an aqueous solution onto coconut shell activated carbon using batch methods. Batch kinetic data were fitted to the first-order model and the pseudo-second-order model, and this last equation fits correctly the experimental data. Equilibrium experiments were carried out at 30°C, 40°C, and 50°C. The adsorption isotherms were reasonably fit using Langmuir model, and the adsorption process was slightly influenced by changes in temperature. Thermodynamic parameters (ΔH°, ΔG°, and ΔS°) were determined. The adsorption process seems to be non-favorable, exothermic, and have an increase in the orderness.
The role of Eichhornia crassipes for removing pollutants from low strength sewage was evaluated in three pilot-scale constructed wetlands (CW): CW 1, planted with E. crassipes in a filter media; CW 2, unplanted, composed by filter media; and CW 3, composed by E. crassipes floating on the sewage. The operation was divided into three stages by varying the nominal hydraulic retention time into: (I) 24 h; (II) 48 h; (III) 72 h. Temporal sampling profiles were carried out with collection of the influent and effluent samples to determine temperature, pH, chemical oxygen demand (COD), TKN and TP. Contents of TP and TN were analyzed in the plant tissue of the macrophyte. The best removal efficiency rates for phosphorus (38%) and TKN (47%) were obtained in CW 3 for 72 h. The highest COD removal was observed in the CW 2 (80%) for 48 h. The macrophyte E. crassipes contributed to the absorption process with uptake rate percentages of 8.3% (CW 1) and 9.0% (CW 3) for TN and 0.78% (CW 1) and 1.56% (CW 3) for TP on the dry matter of the plant. The chosen species planted in the systems contributed to the achievement of higher nutrient removal.
The eutrophication and increase in toxicity promoted by the continuous or abundant supply of nutrients in water bodies threaten the safety of drinking water and human health. In this regard, this study proposes the investigation of wastewater treatment focusing on the simultaneous removal of nitrogen and phosphorus in the anaerobic–oxic–anoxic (AOA) system. The AOA system was operated in three different stages to verify the influence of the external carbon source addition in the anoxic reactor and the reduction of hydraulic retention time (HRT) in the anaerobic and oxic reactors for nutrient removal optimization. Results showed that the best performance of the AOA system on nutrient removal was obtained in Stage 3, with the reduction of the HRT in the anaerobic and oxic reactors (HRT = 4 h) while maintaining HRT of 6.4 h in the anoxic reactor with no addition of the external carbon source. Under these conditions, the average removal efficiencies reached 98% for Chemical Oxygen Demand (COD), 88% for Total Ammonia Nitrogen (TAN), 81% for Total Kjeldahl Nitrogen (TKN), and 70% for Total Phosphorus (TP). The results also demonstrate that the highest phosphorus removal efficiency was achieved in the anoxic reactor, thus indicating the occurrence of denitrifying phosphorous removal by Denitrifying Phosphate Accumulating Organisms (DNPAOs). This configuration was efficient regarding the simultaneous removal of nitrogen and phosphorus; besides, the advantages of this system include robust configuration and excellent performance on the nutrient removal. GRAPHICAL ABSTRACT