The eutrophication and increase in toxicity promoted by the continuous or abundant supply of nutrients in water bodies threaten the safety of drinking water and human health. In this regard, this study proposes the investigation of wastewater treatment focusing on the simultaneous removal of nitrogen and phosphorus in the anaerobic–oxic–anoxic (AOA) system. The AOA system was operated in three different stages to verify the influence of the external carbon source addition in the anoxic reactor and the reduction of hydraulic retention time (HRT) in the anaerobic and oxic reactors for nutrient removal optimization. Results showed that the best performance of the AOA system on nutrient removal was obtained in Stage 3, with the reduction of the HRT in the anaerobic and oxic reactors (HRT = 4 h) while maintaining HRT of 6.4 h in the anoxic reactor with no addition of the external carbon source. Under these conditions, the average removal efficiencies reached 98% for Chemical Oxygen Demand (COD), 88% for Total Ammonia Nitrogen (TAN), 81% for Total Kjeldahl Nitrogen (TKN), and 70% for Total Phosphorus (TP). The results also demonstrate that the highest phosphorus removal efficiency was achieved in the anoxic reactor, thus indicating the occurrence of denitrifying phosphorous removal by Denitrifying Phosphate Accumulating Organisms (DNPAOs). This configuration was efficient regarding the simultaneous removal of nitrogen and phosphorus; besides, the advantages of this system include robust configuration and excellent performance on the nutrient removal. GRAPHICAL ABSTRACT
30 June 2023 in Journal of Environmental Chemical Engineering
Recent studies point out losses of 30–40% of the produced methane in the effluent of anaerobic reactors treating sewage, reducing the renewable energy potential and the environmental footprint. A novel bench-scale upflow anaerobic hybrid (UAHB) reactor combining a sludge blanket at the bottom and a filter media at the top, both with three-phase separators, was proposed to evaluate the recovery of dissolved methane. UAHB was operated with volumetric organic loading rate of 1.24 kg COD m−3 d−1 and hydraulic retention time of 8 h for 218 days to evaluate the influence of temperature (18°C, 23°C, and 28°C) in the methane dissolved in the effluent and collected from three-phase separators. Chemical oxygen demand (COD) and total suspended solids (TSS) removals efficiencies remained constant during the operation and equal to 90 and 95%, respectively, related to the activity of biomass retained in the filter media. Temperature increase influenced more the methane production in the sludge blanket rather than in the upper bed. The volume of recovered methane increased about 20% with the installation of the support media and the upper three-phase separator (3PHS). The loss of methane dissolved in the effluent was strongly influenced by the temperature, and higher with the decrease of this parameter. Non-statistically significant correlations were observed between the temperature and the methane production in the upper bed (p-value = 0.0943) and total (p-value = 0.0930). Thus, it can be concluded that the evaluated temperatures did not influence the global efficiency and the total methane yield of the UAHB reactor. GRAPHICAL ABSTRACT
The hydrodynamic behavior of an anaerobic fixed bed reactor (AFBR) was evaluated in the treatment of cattle slaughterhouse wastewater. The AFBR was operated at hydraulic retention time (HRT) of 14, 11 and 8 h. Stimulus-response assays were carried out with Eosin Y and the experimental data were adjusted to the single-parameter theoretical models of dispersion and N-continuous stirred tank reactors in series (N-CSTR). The experimental results of the residence time distribution curves showed that at lower flow rate, the reactor showed plug flow behavior with correlation coefficient (r) of 0.88 and number of dispersion of 0.2 for high dispersion (HD). However, at higher and intermediate flow rates, the AFBR behave as a complete mixture flow, (r) of 0.94 and 0.96, respectively. Residence time distribution curves in the AFBR showed a good approximation of the complete mixing model at hydraulic residence time of 11 and 8 h, with 5 and 2 N-CSTR reactors in series, respectively. The volume of dead zones corresponding to 43.0, 37.4 and 11.2% of the volume of the reactor for HRT of 14, 11 and 8 h, respectively, was noted, and hydraulic short circuiting were not confirmed.
This paper sought to evaluate the behavior of an upflow Anaerobic-Aerobic Fixed Bed Reactor (AAFBR) in the treatment of cattle slaughterhouse effluent and determine apparent kinetic constants of the organic matter removal. The AAFBR was operated with no recirculation (Phase I) and with 50% of effluent recirculation (Phase II), with θ of 11h and 8h. In terms of pH, bicarbonate alkalinity and volatile acids, the results indicated the reactor ability to maintain favorable conditions for the biological processes involved in the organic matter removal in both operational phases. The average removal efficiencies of organic matter along the reactor height, expressed in terms of raw COD, were 49% and 68% in Phase I and 54% and 86% in Phase II for θ of 11h and 8h, respectively. The results of the filtered COD indicated removal efficiency of 52% and k = 0.0857h-1 to θ of 11h and 42% and k = 0.0880h-1 to θ of 8h in the Phase I. In Phase II, the removal efficiencies were 59% and 51% to θ of 11h and 8h, with k = 0.1238h-1 and k = 0.1075 h-1, respectively. The first order kinetic model showed good adjustment and described adequately the kinetics of organic matter removal for θ of 11h, with r² equal to 0.9734 and 0.9591 to the Phases I and II, respectively.