14 December 2022 in Green Chemistry
Benzoic acids and phenols were obtained through a tBuOK–O2 system realizing the degradation of lignin model compounds through continuous oxidation. The process is carried out at room temperature without the participation of a metal catalyst.
3 March 2022 in IEEE Transactions on Power Electronics
In magnetic resonance imaging (MRI), high-power gradient power amplifiers (GPAs) are required to drive the gradient coils to generate strong and high-fidelity gradient fields. High precision is an essential requirement for the GPAs since precision directly impacts MRI imaging quality. Various aspects of the GPA have been the subject of research in the past years; however, high-precision GPA control that meets the stringent requirements of MRI applications is still a challenge. This article proposes a novel multi-rational-delay variables state space control method and an efficient out-of-band signal injection method to achieve GPA control accuracy at the level of one part per million at MVA output power levels. First, a systematic modeling and design method of the state space controller for high-power GPA is introduced utilizing state vectors with multi-rational-delay variables. This method improves the GPA dynamic performance significantly. Second, an efficient out-of-band signal injection method is presented to further improve the control precision at low output current, enabling the fulfillment of the challenging high-precision MRI requirements over the full GPA output range. Finally, the high-precision control method is validated in a GPA demonstrator with 500 A/1000 V output. Key results are a 30% improvement in current pulse reproducibility with respect to the conventional control method and a factor of 2.5 less noise at low currents. These experimental results validate the proposed novel method for the high-precision control of GPAs in MRI applications and prove its capability to contribute to significantly improved MRI image quality.
25 March 2022 in IEEE Transactions on Power Electronics
High-resolution gradient power amplifiers are required to generate high-fidelity gradient fields in magnetic resonance imaging (MRI) systems. Various aspects of gradient power amplifiers have been the subject of research in the past years, however, systematic analysis and design methods for its resolution improvement have not been sufficiently addressed. This article addresses this research gap with comprehensive analysis and design methods for resolution improvement. First, a method for systematic resolution characterization of the MRI gradient power amplifier with gradient coil is proposed. Second, noise modeling with respect to the critical aspects in the system resolution degradation is developed and discussed. Third, the resolution improvement methods of bandwidth optimization, pseudorandom code modulation, and utilizing silicon carbide (SiC) switching power devices are proposed and analyzed, achieving a resolution at the one part in ${10^6}$ level. Finally, the resolution improvement methods are experimentally validated in a 1000 V/400 A SiC gradient power amplifier. The experimental results show a 3.6 times reduction in the peak spurious signals and resolution improvement at all current levels and pulse lengths, compared to a conventional insulated gate bipolar transistor GPA. These results prove the validity of the proposed methods for resolution improvement in a high-power MRI gradient power amplifier, enabling future high-power and high-resolution amplifier designs.