Keqiu Zeng

Keqiu Zeng

Auto-generated profile, based on publicly available information

Keqiu Zeng

Philips Healthcare (Suzhou) Company, Ltd., Suzhou, China

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 November 2023 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
LWLei Wang
Lei Wang
WWWenbo Wang
Wenbo Wang
KZKeqiu Zeng
Keqiu Zeng
JDJunyun Deng
Junyun Deng
GRGerrit Rietveld
Gerrit Rietveld
RHRaymond Hueting
Raymond Hueting
Conventional packaging technologies cannot facilitate full utilization of wide bandgap (WBG) power modules due to the parasitics of wire bonds and the thermal stresses in solder layers. Pressure contact technology is considered to be an effective approach to reduce stress and to make the assembly compact by replacing solder materials and wire bonds. This article reviews the state of the art of pressure contact packaging and discusses the advantages and limitations of various adopted methodologies. The challenges are revealed in detail in terms of die metallization, multiphysical design, stress distribution, and failures in pressure-based joints. In addition, potential future trends of pressure contact packaging toward different power levels and strategies to select appropriate technologies for different scenarios are discussed. This work aims to support designers in implementing pressure contacts in WBG power modules to fully exploit their advantages and to improve the reliability in thermal cycling.

3 March 2022 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
KZKeqiu Zeng
Keqiu Zeng
SMSaijun Mao
Saijun Mao
GRGerrit Rietveld
Gerrit Rietveld
Jelena PopovicJelena Popovic
Jelena Popovic
HYHui Yu
Hui Yu
ZZZhiding Zhou
Zhiding Zhou
In magnetic resonance imaging (MRI), high-power gradient power amplifiers (GPAs) are required to drive the gradient coils to generate strong and high-fidelity gradient fields. High precision is an essential requirement for the GPAs since precision directly impacts MRI imaging quality. Various aspects of the GPA have been the subject of research in the past years; however, high-precision GPA control that meets the stringent requirements of MRI applications is still a challenge. This article proposes a novel multi-rational-delay variables state space control method and an efficient out-of-band signal injection method to achieve GPA control accuracy at the level of one part per million at MVA output power levels. First, a systematic modeling and design method of the state space controller for high-power GPA is introduced utilizing state vectors with multi-rational-delay variables. This method improves the GPA dynamic performance significantly. Second, an efficient out-of-band signal injection method is presented to further improve the control precision at low output current, enabling the fulfillment of the challenging high-precision MRI requirements over the full GPA output range. Finally, the high-precision control method is validated in a GPA demonstrator with 500 A/1000 V output. Key results are a 30% improvement in current pulse reproducibility with respect to the conventional control method and a factor of 2.5 less noise at low currents. These experimental results validate the proposed novel method for the high-precision control of GPAs in MRI applications and prove its capability to contribute to significantly improved MRI image quality.

25 March 2022 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
KZKeqiu Zeng
Keqiu Zeng
Jelena PopovicJelena Popovic
Jelena Popovic
GRGerrit Rietveld
Gerrit Rietveld
SMSaijun Mao
Saijun Mao
HYHui Yu
Hui Yu
ZZZhiding Zhou
Zhiding Zhou
High-resolution gradient power amplifiers are required to generate high-fidelity gradient fields in magnetic resonance imaging (MRI) systems. Various aspects of gradient power amplifiers have been the subject of research in the past years, however, systematic analysis and design methods for its resolution improvement have not been sufficiently addressed. This article addresses this research gap with comprehensive analysis and design methods for resolution improvement. First, a method for systematic resolution characterization of the MRI gradient power amplifier with gradient coil is proposed. Second, noise modeling with respect to the critical aspects in the system resolution degradation is developed and discussed. Third, the resolution improvement methods of bandwidth optimization, pseudorandom code modulation, and utilizing silicon carbide (SiC) switching power devices are proposed and analyzed, achieving a resolution at the one part in ${10^6}$ level. Finally, the resolution improvement methods are experimentally validated in a 1000 V/400 A SiC gradient power amplifier. The experimental results show a 3.6 times reduction in the peak spurious signals and resolution improvement at all current levels and pulse lengths, compared to a conventional insulated gate bipolar transistor GPA. These results prove the validity of the proposed methods for resolution improvement in a high-power MRI gradient power amplifier, enabling future high-power and high-resolution amplifier designs.

4 February 2025 in IEEE Transactions on Components, Packaging and Manufacturing Technology
Verified
Journal Article
Closed access
LWLisheng Wang
Lisheng Wang
JDJunyun Deng
Junyun Deng
KZKeqiu Zeng
Keqiu Zeng
HCHaoguan Cheng
Haoguan Cheng
QWQiang Wu
Qiang Wu
RHRaymond Hueting
Raymond Hueting
Embedded packaging of wide bandgap power modules offers an inherently lower parasitic inductance, higher switching frequency and lower power losses compared to traditional wire-bonding technology. However, the present embedded technology suffers from a relatively tight laser drilling process window and unknown reliability. This work presents a new embedded packaging technology with minimal thermo-mechanical interfacial stress and a relaxed process window. For this purpose, a pre-sintered die top system (DTS) layer for an improved laser drilling process window with minimal interfacial stress in the topside interconnection is adopted. To design and fabricate the proposed new embedded power module, the interaction between different ceramics and the lamination resin is also studied. Furthermore, the thermal and thermomechanical stress characteristics of the proposed embedded, conventional embedded and wire-bonded power modules have been analyzed and compared through FEM multiphysics simulations in order to evaluate the performance of the three packaging approaches. The simulations indicate that despite the maximum von Mises stress of silicon-nitride (Si3N4) is the highest compared to its substrate counterparts, the obtained maximum stress is much lower than its flexural strength and thus is the best choice of substrate material. The silicon-carbide (SiC) module prototypes fabricated based on the proposed embedding technique show a good laser drilling performance, resulting in an excellent plating quality. In addition, our fabrication results show good agreement with the out-of-plane deformation simulation results. Finally, the proposed module exhibits good reproducibility and process stability due to the protection of the DTS layer.

17 June 2025 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
LWLei Wang
Lei Wang
WWWenbo Wang
Wenbo Wang
KZKeqiu Zeng
Keqiu Zeng
RZRuomeng Zhang
Ruomeng Zhang
GRGerrit Rietveld
Gerrit Rietveld
RHRaymond Hueting
Raymond Hueting
Pressure contact technology (PCT) in power modules offers advantages in improved thermo-mechanical performance and double-sided cooling. This work presents the design and implementation of a proposed PCT in a half-bridge SiC active metal brazed (AMB)-based module. The 3D layout of the power loop provides external degrees of freedom to minimize the commutation loop inductance and to balance the current. To accommodate the small footprint of SiC MOSFETs, graphene films (GFs) and fuzz buttons are applied for the source/drain connectors and gate pins, respectively. These soft connectors not only conduct current and heat but also absorb a certain amount of thermal stress. A thermo-mechanical coupled model under fluid cooling condition is developed to precisely compare the performance of the modules fabricated both with Molybdenum (Mo) and GF connectors. The implementation of GFs significantly reduces the junction temperature and balances the stress of the chips. The double-sided cooling reduces the measured junction to heatsink thermal resistance of the experimental prototype with GF to 0.68 K/W. The double pulse test of the prototype demonstrates a low parasitic inductance of 5.1 nH and a voltage overshoot of only 5.8 %.

19 May 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
KZKeqiu Zeng
Keqiu Zeng
GRGerrit Rietveld
Gerrit Rietveld
Jelena PopovicJelena Popovic
Jelena Popovic
HYHui Yu
Hui Yu
Accurate measurement of fast-changing direct current (DC) is of great importance for high-power, high-resolution amplifiers generating fast-changing pulsed DC currents, as for example used in magnetic resonance imaging systems. A setup and a comprehensive measurement method is developed for the accurate determination of fast-changing DC currents up to 900 A for evaluating these amplifiers. By using a comprehensive analysis method, the predominant factors and noise sources affecting the accurate determination of the amplifier current pulse reproducibility are studied. To further reduce the noise of the readout electronics in the measurement system, a noise reduction method based on correlation analysis is developed. Experiments have subsequently been carried out to prove the validity of the theorical analysis and the design method. The experiments show that a single measurement channel achieves a current pulse reproducibility of around 1.1 μAs. Using two channels and the correlation analysis method gives around 80 % improvement in the measurement noise, resulting in a current pulse reproducibility of around 0.25 μAs, which is more than a factor 20 improvement with respect to the state of the art. These results and the successful final application of the new setup in an actual high-power, high-resolution power amplifier confirm the effectiveness of this new measurement method.