Martin Høyer Rose

Martin Høyer Rose

Auto-generated profile, based on publicly available information

Martin Høyer Rose

Department of Surgery, Center for Surgical Science, Zealand University Hospital, Køge, Denmark

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 September 2025 in Nature Medicine
Verified
Journal Article
Open access
PDF file
ARAndreas Weinberger Rosen
Andreas Weinberger Rosen
IOIlze Ose
Ilze Ose
MGMikail Gögenur
Mikail Gögenur
LALars Peter Kloster Andersen
Lars Peter Kloster Andersen
RBRasmus Dahlin Bojesen
Rasmus Dahlin Bojesen
IGIsmail Gögenur
Ismail Gögenur
Adverse outcomes after elective cancer surgery are a main contributor to decreased survival, poorer oncological outcomes and increased healthcare costs. Identifying high-risk patients and selecting interventions according to individual risk profiles in the perioperative period in cancer surgery is a challenge. Using real-world data on 18,403 patients with colorectal cancer from Danish national registries and consecutive patients from a single center, we developed, validated and implemented an artificial-intelligence-based risk prediction model in clinical practice as a decision support tool for personalized perioperative treatment. Personalized treatment pathways were designed according to the predicted risk of 1-year mortality with the intensity of interventions increasing with the predicted risk. The developed model had an area under the receiver operating characteristic curve of 0.79 in the validation set. Results from the nonrandomized before/after cohort study showed an incidence proportion of the comprehensive complication index >20 of 19.1% in the personalized treatment group versus 28.0% in the standard-of-care group, adjusted odds ratio of 0.63 (95% confidence interval, 0.42–0.92; P = 0.02). The incidence of any medical complication was 23.7% in the personalized treatment group and 37.3% in the standard-of-care group; odds ratio of 0.53 (95% confidence interval, 0.36–0.76; P < 0.001). According to the short-term health economic modeling, personalized perioperative treatment was cost effective. The study demonstrates a fully scalable registry-based approach for using readily available data in an artificial-intelligence-based decision support pipeline in clinical practice. Our results indicate that this specific approach can be a cost-effective strategy to improve key surgical clinical outcomes.

1 January 2013 in Critical Care Medicine
Verified
Journal Article
Closed access
JPJesper B. Poulsen
Jesper B. Poulsen
MRMartin H. Msc Rose
Martin H. Msc Rose
BJBente R. Jensen
Bente R. Jensen
KMKirsten Md Møller
Kirsten Md Møller
APAnders Perner
Anders Perner
Objectives: ICU admission is associated with decreased physical function for years after discharge. The underlying mechanisms responsible for this muscle function impairment are undescribed. The aim of this study was to describe the biomechanical properties of the quadriceps muscle in ICU survivors 12 months after ICU discharge. Design: Case-control study with consecutive inclusion of ICU survivors and age- and sex-matched controls. Setting: Patients were treated at a mixed 18-bed ICU at a tertiary care university hospital and tested at a biomechanical university laboratory. Patients: We included 16 male ICU patients (Acute Physiology and Chronic Health Evaluation II score 20 ± 7, mean ± SD), who had stayed in the ICU >72 hrs and survived to 12 months and 15 age- and sex-matched controls. Interventions: None. Measurements and Main Results: An extensive battery of biomechanical tests, including maximum, fast, and endurance contractions, was administered during isometric knee extensions while simultaneously recording surface electromyography (quadriceps and hamstrings). Compared to controls, ICU survivors had reduced maximal voluntary torque (22%, 179 ± 64 Nm vs. 230 ± 57 Nm, p = 0.03), absolute rate of force development (50%, 868 ± 372 Nm/sec vs. 1739 ± 470 Nm/sec, p < 0.001) and relative rate of force development (32%, 512 ± 260% maximum voluntary contraction/sec vs. 754 ± 189% maximum voluntary contraction/sec, p < 0.01), and endurance time (40%, 136 ± 84 sec vs. 226 ± 111 sec, p < 0.02). Rate of force development, but not maximal voluntary torque, was significantly reduced after adjusting for muscle mass. Electromyography data indicated no impairment of motor activation strategy or central motor drive. Also, no difference in reaction time was found between patients and controls. Conclusions: ICU survivors had reduced rate of force development and muscular endurance 1 yr after ICU discharge. Our data indicate that the functional deficits experienced by ICU survivors originate in muscle tissue rather than the nervous system. Also, increased attention to velocity-orientated exercise during rehabilitation of ICU patients may have the potential to better physical outcome after critical illness.

6 August 2009 in Muscle & Nerve
Verified
Journal Article
Closed access
PDF file
TBThomas Bandholm
Thomas Bandholm
MRMartin H. Rose
Martin H. Rose
RSRikke Sløk
Rikke Sløk
SSStig Sonne‐Holm
Stig Sonne‐Holm
BJBente R. Jensen
Bente R. Jensen

5 November 2024 in Scientific Reports
Verified
Journal Article
Open access
PDF file
ALAnders Lenskjold
Anders Lenskjold
MBMathias W Brejnebøl
Mathias W Brejnebøl
MRMartin H Rose
Martin H Rose
HGHenrik Gudbergsen
Henrik Gudbergsen
ACAkshay Chaudhari
Akshay Chaudhari
MBMikael Boesen
Mikael Boesen
Humans have been shown to have biases when reading medical images, raising questions about whether humans are uniform in their disease gradings. Artificial intelligence (AI) tools trained on human-labeled data may have inherent human non-uniformity. In this study, we used a radiographic knee osteoarthritis external validation dataset of 50 patients and a six-year retrospective consecutive clinical cohort of 8,273 patients. An FDA-approved and CE-marked AI tool was tested for potential non-uniformity in Kellgren-Lawrence grades between the right and left sides of the images. We flipped the images horizontally so that a left knee looked like a right knee and vice versa. According to human review, the AI tool showed non-uniformity with 20–22% disagreements on the external validation dataset and 13.6% on the cohort. However, we found no evidence of a significant difference in the accuracy compared to senior radiologists on the external validation dataset, or age bias or sex bias on the cohort. AI non-uniformity can boost the evaluated performance against humans, but image areas with inferior performance should be investigated.