Mathias Willadsen Brejnebøl

Mathias Willadsen Brejnebøl

Auto-generated profile, based on publicly available information

Mathias Willadsen Brejnebøl

Department of Radiology, Copenhagen University Hospital – Bispebjerg and Frederiksberg, Copenhagen, Denmark

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2023 in Radiology
Verified
Journal Article
Closed access
LPLouis Lind Plesner
Louis Lind Plesner
FMFelix C. Müller
Felix C. Müller
MBMathias W. Brejnebøl
Mathias W. Brejnebøl
LLLene C. Laustrup
Lene C. Laustrup
FRFinn Rasmussen
Finn Rasmussen
MAMichael Brun Andersen
Michael Brun Andersen
Background Commercially available artificial intelligence (AI) tools can assist radiologists in interpreting chest radiographs, but their real-life diagnostic accuracy remains unclear. Purpose To evaluate the diagnostic accuracy of four commercially available AI tools for detection of airspace disease, pneumothorax, and pleural effusion on chest radiographs. Materials and Methods This retrospective study included consecutive adult patients who underwent chest radiography at one of four Danish hospitals in January 2020. Two thoracic radiologists (or three, in cases of disagreement) who had access to all previous and future imaging labeled chest radiographs independently for the reference standard. Area under the receiver operating characteristic curve, sensitivity, and specificity were calculated. Sensitivity and specificity were additionally stratified according to the severity of findings, number of findings on chest radiographs, and radiographic projection. The χ2 and McNemar tests were used for comparisons. Results The data set comprised 2040 patients (median age, 72 years [IQR, 58-81 years]; 1033 female), of whom 669 (32.8%) had target findings. The AI tools demonstrated areas under the receiver operating characteristic curve ranging 0.83-0.88 for airspace disease, 0.89-0.97 for pneumothorax, and 0.94-0.97 for pleural effusion. Sensitivities ranged 72%-91% for airspace disease, 63%-90% for pneumothorax, and 62%-95% for pleural effusion. Negative predictive values ranged 92%-100% for all target findings. In airspace disease, pneumothorax, and pleural effusion, specificity was high for chest radiographs with normal or single findings (range, 85%-96%, 99%-100%, and 95%-100%, respectively) and markedly lower for chest radiographs with four or more findings (range, 27%-69%, 96%-99%, 65%-92%, respectively) (P < .001). AI sensitivity was lower for vague airspace disease (range, 33%-61%) and small pneumothorax or pleural effusion (range, 9%-94%) compared with larger findings (range, 81%-100%; P value range, > .99 to < .001). Conclusion Current-generation AI tools showed moderate to high sensitivity for detecting airspace disease, pneumothorax, and pleural effusion on chest radiographs. However, they produced more false-positive findings than radiology reports, and their performance decreased for smaller-sized target findings and when multiple findings were present. © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Yanagawa and Tomiyama in this issue.

12 March 2022 in European Journal of Radiology
Verified
Journal Article
Open access
MBMathias Willadsen Brejnebøl
Mathias Willadsen Brejnebøl
PHPhilip Hansen
Philip Hansen
JNJanus Uhd Nybing
Janus Uhd Nybing
RBRikke Bachmann
Rikke Bachmann
URUlrik Ratjen
Ulrik Ratjen
MBMikael Boesen
Mikael Boesen
To externally validate an artificial intelligence (AI) tool for radiographic knee osteoarthritis severity classification on a clinical dataset. This retrospective, consecutive patient sample, external validation study used weight-bearing, non-fixed-flexion posterior-anterior knee radiographs from a clinical production PACS. The index test was ordinal Kellgren-Lawrence grading by an AI tool, two musculoskeletal radiology consultants, two reporting technologists, and two resident radiologists. Grading was repeated by all readers after at least four weeks. Reference test was the consensus of the two consultants. The primary outcome was quadratic weighted kappa. Secondary outcomes were ordinal weighted accuracy, multiclass accuracy and F1-score. 50 consecutive patients between September 24, 2019 and October 22, 2019 were retrospectively included (3 excluded) totaling 99 knees (1 excluded). Quadratic weighted kappa for the AI tool and the consultant consensus was 0.88 CI95% (0.82-0.92). Agreement between the consultants was 0.89 CI95% (0.85-0.93). Intra-rater agreements for the consultants were 0.96 CI95% (0.94-0.98) and 0.94 CI95% (0.91-0.96) respectively. For the AI tool it was 1 CI95% (1-1). For the AI tool, ordinal weighted accuracy was 97.8% CI95% (96.9-98.6 %). Average multiclass accuracy and F1-score were 84% (83/99) CI95% (77-91%) and 0.67 CI95% (0.51-0.81). The AI tool achieved the same good-to-excellent agreement with the radiology consultant consensus for radiographic knee osteoarthritis severity classification as the consultants did with each other.

1 September 2020 in Radiology
Verified
Journal Article
Closed access
FMFelix C. Müller
Felix C. Müller
KGKasper K. Gosvig
Kasper K. Gosvig
HBHenrik Børgesen
Henrik Børgesen
JGJesper S. Gade
Jesper S. Gade
MBMathias Brejnebøl
Mathias Brejnebøl
MBMikael Boesen
Mikael Boesen
In this prospective study, dual-energy CT and MRI had a similarly high sensitivity and specificity in helping detect radiographically negative wrist fractures. Background Patients with wrist trauma and negative findings on radiographs often undergo additional MRI examinations to assess for radiographically occult fractures. Dual-energy CT may be more read...

1 July 2024 in Radiology
Verified
Journal Article
Closed access
MBMathias W. Brejnebøl
Mathias W. Brejnebøl
ALAnders Lenskjold
Anders Lenskjold
KZKatharina Ziegeler
Katharina Ziegeler
HRHuib Ruitenbeek
Huib Ruitenbeek
FMFelix C. Müller
Felix C. Müller
MBMikael Boesen
Mikael Boesen
In this retrospective, three-center, multireader study using consecutive knee radiographs in patients with suspected osteoarthritis, concurrent artificial intelligence assistance improved osteoarthritis grading performance of junior readers and increased interobserver agreement across all readers.

26 February 2022 in European Journal of Radiology
Verified
Journal Article
Open access
MBMathias W. Brejnebøl
Mathias W. Brejnebøl
YNYousef W. Nielsen
Yousef W. Nielsen
OTOliver Taubmann
Oliver Taubmann
EEEva Eibenberger
Eva Eibenberger
FMFelix C. Müller
Felix C. Müller
The primary aim was to investigate the diagnostic performance of an Artificial Intelligence (AI) algorithm for pneumoperitoneum detection in patients with acute abdominal pain who underwent an abdominal CT scan. This retrospective diagnostic test accuracy study used a consecutive patient cohort from the Acute High-risk Abdominal patient population at Herlev and Gentofte Hospital, Denmark between January 1, 2019 and September 25, 2019. As reference standard, all studies were rated for pneumoperitoneum (subgroups: none, small, medium, and large amounts) by a gastrointestinal radiology consultant. The index test was a novel AI algorithm based on a sliding window approach with a deep recurrent neural network at its core. The primary outcome was the area under the curve (AUC) of the receiver operating characteristic (ROC). Of 331 included patients (median age 68 years (Range 19-100; 180 women)) 31 patients (9%) had pneumoperitoneum (large: 16, moderate: 7, small: 8). The AUC was 0.77 (95% CI 0.66-0.87). At a specificity of 99% (297/300, 95% CI: 97-100%), sensitivity was 52% (16/31, 95% CI 29-65%), and positive likelihood ratio was 52 (95% CI 16-165). When excluding cases with smaller amounts of free air (<0.25 mL) the AUC increased to 0.96 (95% CI 0.89-1.0). At 99% specificity, sensitivity was 81% (13/16) and positive likelihood ratio was 82 (95% CI 27 - 254). An AI algorithm identified pneumoperitoneum on CT scans in a clinical setting with low sensitivity but very high specificity, supporting its role for ruling in pneumoperitoneum.

1 August 2024 in Radiology
Verified
Journal Article
Closed access
LPLouis Lind Plesner
Louis Lind Plesner
FMFelix C. Müller
Felix C. Müller
MBMathias W. Brejnebøl
Mathias W. Brejnebøl
CKChristian Hedeager Krag
Christian Hedeager Krag
LLLene C. Laustrup
Lene C. Laustrup
MAMichael Brun Andersen
Michael Brun Andersen
A commercial AI tool used off-label correctly excluded pathology in 24.5%–52.7% of unremarkable chest radiographs at greater than or equal to 98% sensitivity, with lower rates of critical misses than radiology reports.