Krzysztof Szymaniec

Krzysztof Szymaniec

Auto-generated profile, based on publicly available information

Krzysztof Szymaniec

National Physical Laboratory

Research Focus & Metrics

Academic Career Length

30Years (1997-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2023 in New Journal of Physics
Verified
Journal Article
Open access
PDF file
NSNathaniel Sherrill
Nathaniel Sherrill
APAdam O Parsons
Adam O Parsons
CBCharles F A Baynham
Charles F A Baynham
WBWilliam Bowden
William Bowden
ECElizabeth Anne Curtis
Elizabeth Anne Curtis
Xavier  CalmetXavier Calmet
Xavier Calmet
We present a new framework to study the time variation of fundamental constants in a model-independent way. Model independence implies more free parameters than assumed in previous studies. Using data from atomic clocks based on87Sr,171Yb+and133Cs, we set bounds on parameters controlling the variation of the fine-structure constant,α, and the electron-to-proton mass ratio,µ. We consider variations on timescales ranging from a minute to almost a day. In addition, we use our results to derive some of the tightest limits to date on the parameter space of models of ultralight dark matter and axion-like particles.

27 April 2020 in Metrologia
Verified
Journal Article
Open access
PDF file
SBScott Beattie
Scott Beattie
BJBin Jian
Bin Jian
JAJohn Alcock
John Alcock
MGMarina Gertsvolf
Marina Gertsvolf
RHRich Hendricks
Rich Hendricks
KGKurt Gibble
Kurt Gibble

8 October 2018 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
RHRichard J. Hendricks
Richard J. Hendricks
FOFilip Ozimek
Filip Ozimek
KSKrzysztof Szymaniec
Krzysztof Szymaniec
BNBartlomiej Nagorny
Bartlomiej Nagorny
PDPiotr Dunst
Piotr Dunst
KGKurt Gibble
Kurt Gibble
We report on the design, assembly, testing and delivery of a series of new caesium fountain primary frequency standards built through commercial and scientific collaboration with international users. The new design, based on proven NPL solutions, improves reliability, simplicity of operation and transportability. The complete system consists of a novel physics package, a specially developed optical package and dedicated electronics for system control. We present results showing that despite their simplified and more compact design, the new fountains have state-of-the-art performance in terms of signal-to-noise ratio and robust long-term operation. With a sufficiently low noise local oscillator they are capable of reaching a short-term stability below 3×10−14 (1 s) and have potential accuracy in the low 10−16 range, similar to the best caesium fountains currently in operation. This cost-effective solution could be used to increase the availability of accurate frequency references and timescales and provide redundancy in critical locations.

30 May 2006 in Metrologia
Verified
Journal Article
Closed access
KSK Szymaniec
K Szymaniec
WCWitold Chałupczak
Witold Chałupczak
PWP B Whibberley
P B Whibberley
SLS N Lea
S N Lea
DHD Henderson
D Henderson

5 October 2020 in Metrologia
Verified
Journal Article
Closed access
PDF file
KBKathryn Burrows
Kathryn Burrows
RHR J Hendricks
R J Hendricks
KSKrzysztof Szymaniec
Krzysztof Szymaniec
KGKurt Gibble
Kurt Gibble
SBScott Beattie
Scott Beattie
BJBin Jian
Bin Jian
Distributed cavity phase (DCP) frequency shifts are a leading systematic effect in atomic fountain frequency standards. They originate from the phase variations of the field in the microwave cavity combined with different positions of the atoms in the cavity on the ascent and descent. Here we demonstrate techniques to precisely determine the position of the cloud of atoms in the microwave cavity, using either the approximately linear variation of the transverse components of the microwave field or the quadratic variation of the longitudinal microwave field amplitude in the cavity. We also show that shifting the initial position of the atoms gives a significantly higher sensitivity to DCP variations than the often-used tilting of fountains. A demonstrated centring precision of order 50 μm will enable DCP frequency shift uncertainties to be reduced to less than 10 –17 and thereby contribute insignificantly to the accuracy budget of a standard. These techniques to vertically align a fountain are straightforward to automate for routine operation and require a negligible fraction of the standard’s averaging time.

1 December 1997 in Journal of the Optical Society of America B
Verified
Journal Article
Closed access
PDF file
MLM. Lubińska
M. Lubińska
AWA. Wiecek
A. Wiecek
LJL. Józefowski
L. Józefowski
JKJarosław Koperski
Jarosław Koperski
KSK. Szymaniec
K. Szymaniec
TDT. Dohnalik
T. Dohnalik
Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.