13 March 2024 in IEEE Transactions on Industry Applications
Successful discrimination of, isolation from, and recovery against short-circuit electrical faults within microgrids having distributed energy resources (DERs) is challenging, as protection coordination must include not only the distribution equipment, but also control and low voltage ride-through settings of DERs. This is especially the case when grid resilience is improved by use of the microgrid to maintain services from DERs (localized to an installation) following utility grid outages. Under islanded configurations, continued reliability of power delivery is essential, even in the face of subsequent electrical faults. The main purpose of this paper is to propose a novel protection design process, and to demonstrate it on an islanded ac microgrid with parallel feeders. The contribution is a methodology for coordinated circuit breaker protection and ride-through settings, thereby maximizing the post-fault recoverability of an ac microgrid subject to faults in an islanded configuration. The aim is improve the microgrid resilience in islanded configurations. The protection and IEEE Standard 1547-2018 ride-through settings are validated in controller hardware-in-the-loop simulation, validating the proposed design process. Additionally, detailed implementation of ride-through enabling controls are discussed.
19 August 2020 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Real-time (RT) simulation of power and energy conversion systems allows engineers to interface both simulation- and hardware-based controls using controller hardware-in-the-loop (CHiL) simulation of networks of power electronic converters (PECs) in order to de-risk highly developmental systems such as next generation electrified transportation systems and dc microgrids. CHiL exploration and performance verification moves a design from Technology Readiness Level (TRL) 3 to TRL 4 without incurring significant cost investments in developmental hardware platforms, which otherwise discourages such endeavors. A real-time CHiL simulation platform suitable for explorations of protective equipment, protection schemes and networked PEC dc and mixed dc-ac power distribution architectures must be capable of simulating common-mode behavior, various grounding schemes, and fault transients at sufficiently high resolution. This paper demonstrates this capability using a Latency-Based Linear Multistep Compound (LB-LMC) simulation method implemented in a commercially sustainable, adaptable and expandable FPGA-based test and instrumentation platform. The proposed CHiL platform achieves real-time power system simulations, including detailed switching commutations of networked PECs, with 50 ns resolution, and faithfully produces resonant and transient behaviors associated with line-to-ground (LG) and line-to-line (LL) faults and fault recovery in ungrounded PEC-based dc systems. This resolution in RT cannot be achieved with today’s commercial off-the-shelf CHiL platforms. This paper demonstrates the need for high resolution RT simulation of LG and LL faults within dc systems, and demonstrates a CHiL approach that enables dc protection design explorations and protective control hardware testing while taking into account the realistic aspects that affect fault characteristics in PEC-based dc systems, such as cable current rating and length, cable and PEC parasitic LG capacitance and PEC internal response to fault scenarios.
2 June 2021 in IEEE Transactions on Industry Applications
This article compares the performance of different detection methods for a single-phase inverter interfacing a distributed energy resource during abnormal transients or failures of the utility electric power system voltage. The performance of the various methods is presented and compared to IEEE Standard 1547-2018 requirements using a physics-based model. Simulation scenarios are created to compare controller responses to intentional islanding and ride-through recommended timing specified in IEEE Standard 1547-2018. Additionally, four voltage abnormality detection methods were implemented in a Field Programmable Gate Array (FPGA)-based controller hardware-in-the-loop simulation and assessed for steady state and transient performance, and FPGA resource utilization. Finally, the physics-based model is validated by experimental measurements on a laboratory prototype with an FPGA-based controller.