Diele A. G. Araujo

Diele A. G. Araujo

Auto-generated profile, based on publicly available information

Diele A. G. Araujo

Institute of Chemistry, Department of Fundamental Chemistry, University of São Paulo, 05508-000, São Paulo-SP, Brazil

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2020 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
LPLauro A. Pradela-Filho
Lauro A. Pradela-Filho
IAIsabela A.A. Andreotti
Isabela A.A. Andreotti
JCJefferson Henrique de Souza Carvalho
Jefferson Henrique de Souza Carvalho
DADiele A.G. Araújo
Diele A.G. Araújo
LOLuiz O. Orzari
Luiz O. Orzari
Bruno Campos JanegitzBruno Campos Janegitz
Bruno Campos Janegitz

1 December 2017 in Electrochimica Acta
Verified
Journal Article
Closed access
LPL.A. Pradela-Filho
L.A. Pradela-Filho
DAD.A.G. Araújo
D.A.G. Araújo
RTR.M. Takeuchi
R.M. Takeuchi
ASAndré Santos
André Santos

11 April 2023 in Talanta
Verified
Journal Article
Closed access
CLCarlos E.C. Lopes
Carlos E.C. Lopes
LFLucas V. de Faria
Lucas V. de Faria
DADiele A.G. Araújo
Diele A.G. Araújo
EREduardo M. Richter
Eduardo M. Richter
Thiago PaixaoThiago Paixao
Thiago Paixao
ISIranaldo S. da Silva
Iranaldo S. da Silva

11 February 2024 in Electrochimica Acta
Verified
Journal Article
Closed access
MDMarina Di-Oliveira
Marina Di-Oliveira
DADiele A.G. Araújo
Diele A.G. Araújo
DRDavid L.O. Ramos
David L.O. Ramos
LFLucas de Faria
Lucas de Faria
RRRaquel G. Rocha
Raquel G. Rocha
Rodrigo A. A. MunozRodrigo A. A. Munoz
Rodrigo A. A. Munoz

21 November 2016 in Analytical Methods
Verified
Journal Article
Closed access
PDF file
MFM. A. Franco
M. A. Franco
DAD. A. G. Araújo
D. A. G. Araújo
LOL. H. Oliveira
L. H. Oliveira
MTM. A. G. Trindade
M. A. G. Trindade
RTR. M. Takeuchi
R. M. Takeuchi
ASAndré Santos
André Santos
In this study, a carbon paste electrode was used for the amperometric detection of atenolol (ATN) in a Flow Injection Analysis (FIA) system with recirculation of the carrier solution. Under optimized conditions, the FIA method presented a linear range from 50 to 1000 μmol L−1, with a limit of detection of 8 μmol L−1 and a limit of quantification of 50 μmol L−1. The proposed method was successfully employed for ATN determination in five pharmaceutical formulation samples without interference from pharmaceutical excipients or the concomitant drugs chlortalidone and nifedipine. Recirculation of the carrier solution combines the advantages of using high flow rates (7 mL min−1), i.e. high sensitivity and high analytical frequency (240 injections per h), with very low reagent consumption and waste generation. A non-modified carbon paste electrode as an amperometric detector provides simplicity and low cost to the analytical method. Therefore, the proposed FIA method allows ATN quantification in pharmaceutical formulation samples in a very fast, inexpensive, reliable and environmentally friendly way.

1 November 2021 in Analytica Chimica Acta
Verified
Journal Article
Closed access
DADiele A.G. Araújo
Diele A.G. Araújo
AOAna C.M. Oliveira
Ana C.M. Oliveira
LPLauro A. Pradela-Filho
Lauro A. Pradela-Filho
RTRegina M. Takeuchi
Regina M. Takeuchi
ASAndré Santos
André Santos