Ronald H. Silverman

Ronald H. Silverman

Auto-generated profile, based on publicly available information

Ronald H. Silverman

Department of Ophthalmology, Columbia University Irving Medical Center, New York, NY, USA

Research Focus & Metrics

Academic Career Length

31Years (1996-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2016 in Clinical Ophthalmology
Verified
Journal Article
Open access
PDF file
RSRonald H Silverman
Ronald H Silverman
The use of focused ultrasound to obtain diagnostically significant information about the eye goes back to the 1950s. This review describes the historical and technological development of ophthalmic ultrasound and its clinical application and impact. Ultrasound, like light, can be focused, which is crucial for formation of high-resolution, diagnostically useful images. Focused, single-element, mechanically scanned transducers are most common in ophthalmology. Specially designed transducers have been used to generate focused, high-intensity ultrasound that through thermal effects has been used to treat glaucoma (via cilio-destruction), tumors, and other pathologies. Linear and annular transducer arrays offer synthetic focusing in which precise timing of the excitation of independently addressable array elements allows formation of a converging wavefront to create a focus at one or more programmable depths. Most recently, linear array-based plane-wave ultrasound, in which the array emits an unfocused wavefront and focusing is performed solely on received data, has been demonstrated for imaging ocular anatomy and blood flow. While the history of ophthalmic ultrasound extends back over half-a-century, new and powerful technologic advances continue to be made, offering the prospect of novel diagnostic capabilities.

8 August 2016 in European Journal of Ophthalmology
Verified
Journal Article
Closed access
RSRonald H. Silverman
Ronald H. Silverman
RURaksha Urs
Raksha Urs
ARArindam RoyChoudhury
Arindam RoyChoudhury
TATimothy J. Archer
Timothy J. Archer
MGMarine Gobbe
Marine Gobbe
DRDan Z. Reinstein
Dan Z. Reinstein
Purpose: Scanning Scheimpflug provides information regarding corneal thickness and 2-surface topography while arc-scanned high-frequency ultrasound allows depiction of the epithelial and stromal thickness distributions. Both techniques are useful in detection of keratoconus. Our aim was to develop and test a keratoconus classifier combining information from both methods. Methods: We scanned 111 normal and 30 clinical keratoconus subjects with Artemis-1 and Pentacam data. After selecting one random eye per subject, we performed stepwise linear discriminant analysis on a dataset combining parameters generated by each method to obtain classification models based on each technique alone and in combination. Results: Discriminant analysis resulted in a 4-variable model (R2 = 0.740) based on Artemis data alone and a 4-variable model (R2 = 0.734) using Pentacam data alone. The combined model (R2 = 0.828) consisted of 3 Artemis- and 4 Pentacam-derived variables. The combined model R value was significantly higher than either model alone (p = 0.031, one-tailed). In cross-validation, Artemis had 100% sensitivity and 99.2% specificity, Pentacam had 97.3% sensitivity and 98.0% specificity, and the combined model had 97.3% sensitivity and 100% specificity. Conclusions: Pentacam, Artemis, and combined models were all effective in distinguishing normal from clinical keratoconus subjects. From the standpoint of variance explained by the model (R2 values), the combined model was most effective. Application of the model to early and subclinical keratoconus will ultimately be required to assess the effectiveness of the combined approach.

4 September 2018 in Translational Vision Science & Technology
Verified
Journal Article
Open access
PDF file
RURaksha Urs
Raksha Urs
JKJeffrey A. Ketterling
Jeffrey A. Ketterling
AYAlfred C. H. Yu
Alfred C. H. Yu
HLHarriet O. Lloyd
Harriet O. Lloyd
BYBilly Y. S. Yiu
Billy Y. S. Yiu
RSRonald H. Silverman
Ronald H. Silverman
Purpose: The choroid is a vascular network providing the bulk of the oxygen and nutrient supply to the retina and may play a pivotal role in retinal disease pathogenesis. While optical coherence tomography angiography provides an en face depiction of the choroidal vasculature, it does not reveal flow dynamics. In this report, we describe the use of plane-wave ultrasound to image and characterize choroidal blood flow. Methods: We scanned both eyes of 12 healthy subjects in a horizontal plane superior to the optic nerve head using an 18-MHz linear array. Plane-wave data were acquired over 10 transmission angles that were coherently compounded to produce 1000 images/sec for 3 seconds. These data were processed to produce a time series of power Doppler images and spectrograms depicting choroidal flow velocity. Analysis of variance was used to characterize peak systolic, and end diastolic velocities and resistive index, and their variability between scans, eyes, and subjects. Results: Power Doppler images showed distinct arterioles within a more diffuse background. Choroidal flow was moderately pulsatile, with peak systolic velocity averaging approximately 10 mm/sec and resistive index of 0.55. There was no significant difference between left and right eyes, but significant variation among subjects. Conclusions: Plane-wave ultrasound visualized individual arterioles and allowed measurement of flow over the cardiac cycle. Characterization of choroidal flow dynamics offers a novel means for assessment of the choroid's role in ocular disease. Translational Relevance: Characterization of choroidal flow dynamics offers a novel means for assessment of the choroid's role in ocular disease.

1 May 2015 in The Journal of the Acoustical Society of America
Verified
Journal Article
Closed access
DRDaniel Rohrbach
Daniel Rohrbach
HLHarriet O. Lloyd
Harriet O. Lloyd
RSRonald H. Silverman
Ronald H. Silverman
JMJonathan Mamou
Jonathan Mamou
Ex vivo assessment of microscale tissue biomechanical properties of the mammalian retina could offer insights into diseases such as keratoconus, and macular degeneration. A 250-MHz scanning acoustic microscope (7-μm resolution) has been constructed to derive two-dimensional quantitative maps of attenuation (α), speed of sound (c), acoustic impedance (Z), bulk modulus (B), and mass density (ρ). The two-dimensional maps were compared to coregistered hematoxylin-and-eosin stained sections. This study is the first to quantitatively assess α, c, Z, B, and ρ of individual retinal layers of mammalian animals at high ultrasound frequencies. Significant differences in these parameters between the layers were demonstrated.

1 December 1996 in British Journal of Ophthalmology
Verified
Journal Article
Open access
PDF file
JDJ Danias
J Danias
Ioannis M. AslanidesIoannis M. Aslanides
Ioannis M. Aslanides
JEJ W Eichenbaum
J W Eichenbaum
RSR H Silverman
R H Silverman
DRD Z Reinstein
D Z Reinstein
DCD J Coleman
D J Coleman
AIMS: To elucidate changes in the anatomy of the anterior chamber associated with iridoschisis, a rare form of iris atrophy, and their potential contribution to angle closure glaucoma. METHODS: Both eyes of a 71-year-old woman with bilateral iridoschisis and fibrous dysplasia and her asymptomatic 50-year-old daughter were scanned with a very high frequency (50 MHz) ultrasound system. RESULTS: The symptomatic patient exhibited diffuse changes in the iris stoma with an intact posterior iris pigmented layer in both eyes. These changes were clinically compatible with the lack of iris transillumination defects. Additionally, iris bowing with a resultant narrowing of the angle occurred. The asymptomatic daughter showed discrete, but less severe iris stromal changes. CONCLUSION: This is the first detailed study of high frequency ultrasonic imaging of the iris in iridoschisis. The observed structural changes suggest angle narrowing by forward bowing of the anterior iris stroma may be a mechanism of IOP elevation in this condition. The ultrasonic detection of iris changes in the asymptomatic daughter of the symptomatic patient and the association of iridoschisis with fibrous dysplasia suggest a possible genetic component in the pathogenesis of this condition.

30 November 2017 in Scientific Reports
Verified
Journal Article
Open access
PDF file
JKJeff Ketterling
Jeff Ketterling
OAOrlando Aristizábal
Orlando Aristizábal
BYBilly Y. S. Yiu
Billy Y. S. Yiu
DTDaniel H. Turnbull
Daniel H. Turnbull
CPColin K. Phoon
Colin K. Phoon
RSRonald H. Silverman
Ronald H. Silverman
Real-time imaging of the embryonic murine cardiovascular system is challenging due to the small size of the mouse embryo and rapid heart rate. High-frequency, linear-array ultrasound systems designed for small-animal imaging provide high-frame-rate and Doppler modes but are limited in regards to the field of view that can be imaged at fine-temporal and -spatial resolution. Here, a plane-wave imaging method was used to obtain high-speed image data from in utero mouse embryos and multi-angle, vector-flow algorithms were applied to the data to provide information on blood flow patterns in major organs. An 18-MHz linear array was used to acquire plane-wave data at absolute frame rates ≥10 kHz using a set of fixed transmission angles. After beamforming, vector-flow processing and image compounding, effective frame rates were on the order of 2 kHz. Data were acquired from the embryonic liver, heart and umbilical cord. Vector-flow results clearly revealed the complex nature of blood-flow patterns in the embryo with fine-temporal and -spatial resolution.