Li Sun

Li Sun

Auto-generated profile, based on publicly available information

Li Sun

Polyclinic for Operative Dentistry and Periodontology, University of Cologne, Faculty of Medicine and University Hospital Cologne, Kerpener Str. 32, 50931, Cologne, Germany

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 July 2025 in The Journal of the American Dental Association
Verified
Journal Article
Open access
CSChristoph Matthias Schoppmeier
Christoph Matthias Schoppmeier
MKMax von Kohout
Max von Kohout
LSLi Sun
Li Sun
MJMalin Janson
Malin Janson
IDIsabel Deeg
Isabel Deeg
MWMichael Jochen Wicht
Michael Jochen Wicht
The authors investigated the color stability of resin-infiltrated white-spot lesions (WSL) after in-office tooth bleaching (IB) or home tooth bleaching (HB) and assessed the potential for staining and rebleaching. Sixty caries-free third molars were demineralized to create WSLs and then divided into 4 groups: (1) no treatment (control) group; (2) demineralization plus resin infiltration group; (3) demineralization plus resin infiltration plus IB group; (4) and demineralization plus resin infiltration plus HB group. After exposure to coffee solution to simulate 12-month staining potential, a second bleaching procedure was performed. Color measurements were obtained at 10 defined time points using standardized digital imaging and analyzed in the Commission Internationale de l'Eclairage-L∗a∗b∗ (lightness, red-green axis, yellow-blue axis) color space. To precisely document color changes, time points included baseline, after WSL creation, after resin infiltration, after bleaching procedures, after thermocycling (aging), after coffee exposure, and after rebleaching. No significant differences in bleaching effectiveness were observed between IB and HB after initial (P = .127) or subsequent (P = .111) bleaching. Similarly, there were no significant differences (P = .867) in staining potential between the IB and HB groups after 12 days. Both bleaching methods restored the WSL color close to the baseline after staining. Both IB and HB restored the color of resin-infiltrated WSLs to near-baseline levels after staining in vitro, with no significant differences between the 2 methods. Although results of the treatments showed responsiveness to whitening protocols, color stability under staining conditions remained limited, highlighting the need for further investigation into long-term maintenance strategies. Both IB and HB approaches may be clinically viable for maintaining the esthetic stability of treated WSLs over time once sufficient evidence from clinical studies becomes available.

23 January 2026 in The Saudi Dental Journal
Verified
Journal Article
Open access
CSChristoph Matthias Schoppmeier
Christoph Matthias Schoppmeier
MJMalin Janson
Malin Janson
LSLi Sun
Li Sun
GCGustav Leo Classen
Gustav Leo Classen
ABAnna Greta Barbe
Anna Greta Barbe
Purpose: Nickel–titanium (NiTi) instruments have advanced root canal preparation through enhanced precision. Thermal pretreatment improves both flexibility and cyclic fatigue resistance (CFR). While irrigating solutions are essential for decontamination, they may also affect the properties of heat-treated NiTi instruments. This study aimed to evaluate the impact of different irrigating solutions on the cyclic fatigue resistance of heat-treated NiTi files. Methods: Four heat-treated reciprocating NiTi-files were analyzed: EdgeOne R-Utopia, Reciproc Blue, Procodile Q and CC One Blue. Files were immersed (5 min; 37 °C and 60 °C) in 5.25% sodium hypochlorite (NaOCl), 17% ethylenediaminetetraacetic acid (EDTA), 96% ethanol, NaOCl + EDTA, distilled water, or left in a no-immersion control group. CFR was measured in an artificial root canal (60° curvature, 5 mm radius), and fragment length (FL) was documented. The surface features of the fragments were assessed through scanning electron microscopy. Results: File system, irrigating solution, and temperature significantly influenced CFR (p < 0.001). Across all immersion conditions, the CFR reached its highest value with Procodile Q (37 °C distilled water) and its lowest with EdgeOne R-Utopia (60 °C NaOCl + EDTA). EDTA reduced CFR across all files, particularly at elevated temperatures and when combined with NaOCl. Microscopy revealed micropitting and roughened surfaces, particularly on CC One Blue (60 °C NaOCl), as well as material degradation and heterogeneous surfaces with NaOCl + EDTA. Conclusions: Heat-treated NiTi instruments are influenced in their mechanical and metallurgical behavior by the chemical and thermal impact of irrigating solutions. Heated EDTA and NaOCl + EDTA were detrimental, while Procodile Q demonstrated the highest CFR. Within the limitations of this study, exposure to irrigating solutions, particularly heated EDTA and NaOCl + EDTA, reduced the cyclic fatigue resistance of heat-treated NiTi files. Clinically, prudent selection and temperature control of irrigants may help preserve instrument performance and reduce the risk of file fracture during root canal preparation.