29 October 2023 in Magnetic Resonance in Medicine
8 December 2020 in Magnetic Resonance in Medicine
16 March 2023 in NeuroImage
Velocity-selective inversion (VSI) based velocity-selective arterial spin labeling (VSASL) has been developed to measure cerebral blood flow (CBF) with low susceptibility to the prolonged arterial transit time and high sensitivity to brain perfusion signal. The purpose of this magnetic resonance imaging study is to evaluate the test-retest reliability of a VSI-prepared 3D VSASL protocol with whole-brain coverage to detect baseline CBF variations among cognitively normal participants in different brain regions. Coefficients of variation (CoV) of both absolute and relative CBF across scans or sessions, subjects, and gray matter regions were calculated, and corresponding intraclass correlation coefficients (ICC) were computed. The higher between-subject CoV of absolute CBF (13.4±2.0%) over within-subject CoV (within-session: 3.8±1.1%; between-session: 4.9±0.9%) yielded moderate to excellent ICC (within-session: 0.88±0.08; between-session: 0.77±0.14) to detect normal variations of individual CBF. The higher between-region CoV of relative CBF (11.4±3.0%) over within-region CoV (within-session: 2.3±0.9%; between-session: 3.3±1.0%) yielded excellent ICC (within-session: 0.92±0.06; between-session: 0.85±0.12) to detect normal variations of regional CBF. Age, blood pressure, end-tidal CO2, and hematocrit partially explained the variability of CBF across subjects. Together these results show excellent test-retest reliability of VSASL to detect both between-subject and between-region variations supporting its clinical utility.
1 May 2023 in Magnetic Resonance in Medicine
Purpose: The most‐used 3D acquisitions for ASL are gradient and spin echo (GRASE)– and stack‐of‐spiral (SOS)–based fast spin echo, which require multiple shots. Alternatively, turbo FLASH (TFL) allows longer echo trains, and SOS‐TFL has the potential to reduce the number of shots to even single‐shot, thus improving the temporal resolution. Here we compare the performance of 3D SOS‐TFL and 3D GRASE for ASL at 3T.Methods: The 3D SOS‐TFL readout was optimized with respect to fat suppression and excitation flip angles for pseudo‐continuous ASL– and velocity‐selective (VS)ASL–derived cerebral blood flow (CBF) mapping as well as for VSASL‐derived cerebral blood volume (CBV) mapping. Results were compared with 3D GRASE readout on healthy volunteers in terms of perfusion quantification and temporal SNR (tSNR) efficiency. CBF and CBV mapping derived from 3D SOS‐TFL–based ASL was demonstrated on one stroke patient, and the potential for single‐shot acquisitions was exemplified.Results: SOS‐TFL with a 15° flip angle resulted in adequate tSNR efficiency with negligible image blurring. Selective water excitation was necessary to eliminate fat‐induced artifacts. For pseudo‐continuous ASL– and VSASL‐based CBF and CBV mapping, compared to the employed four‐shot 3D GRASE with an acceleration factor of 2, the fully sampled 3D SOS‐TFL delivered comparable performance (with a similar scan time) using three shots, which could be further undersampled to achieve single‐shot acquisition with higher tSNR efficiency. SOS‐TFL had reduced CSF contamination for VSASL‐CBF.Conclusion: 3D SOS‐TFL acquisition was found to be a viable substitute for 3D GRASE for ASL with sufficient tSNR efficiency, minimal relaxation‐induced blurring, reduced CSF contamination, and the potential of single‐shot, especially for VSASL.
15 May 2024 in Magnetic Resonance in Medicine