Hong Shen

Hong Shen

Auto-generated profile, based on publicly available information

Hong Shen

North China Electric Power University

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 March 2022 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
YSYan Shi
Yan Shi
XCXiang Cui
Xiang Cui
LQLei Qi
Lei Qi
XZXiangyu Zhang
Xiangyu Zhang
XLXuebao Li
Xuebao Li
HSHong Shen
Hong Shen
Due to the lack of alternating electric fields and alternating magnetic fields in HVdc transmission system, there has been no sustainable and stable energy harvesting method compatible with them up to now, hindering the application of HVdc sensors. In this letter, we proposed a novel dc energy harvesting method using corona current, and an energy harvesting circuit is constituted with space ion flow generated by dc corona. The feasibility of the proposed method is increased by adding an artificial corona electrode and placing the load before the corona electrode. In addition, it can flexibly operate at any position in an HVdc transmission system according to actual demand. Then the output power is further maximized by adopting a capacitor with high working voltages. The detailed measurement results based on the experimental system validate the effectiveness of the proposed method, with a stable output power as high as 10.15 mW in a dc system of 22 kV. A detailed discussion of the overall performance is finally carried out.

4 July 2023 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
YLYuanfang Lu
Yuanfang Lu
XZXiangyu Zhang
Xiangyu Zhang
HSHong Shen
Hong Shen
WZWuyu Zhang
Wuyu Zhang
LQLei Qi
Lei Qi
Press pack insulated-gate bipolar transistor (PP IGBT) play an essential role in high-capacity power electronic transmission equipment. Due to the influence of various factors such as structural pressure and temperature in practical operation, the internal parallel chips of the IGBT may experience inevitable current imbalance, which can not be detected by existing method. This letter proposes a segmented Rogowski coil (SRC) based non-invasive monitoring method of current imbalance in Press Pack IGBT. By segmenting the standard Rogowski coils around the IGBT device and measuring them individually, the general distribution of the current inside the device can be perceived. After detailed analysis of the mutual inductance characteristics and transfer function, a prototype of SRC was developed. The theoretical model of SRC has been verified by measuring a single current-carrying wire, with an error of only 1.21%. The effectiveness of the proposed scheme was demonstrated by using it to monitor the current distribution in different directions for the same IGBT device.

4 July 2022 in High Voltage
Verified
Journal Article
Open access
LQLei Qi
Lei Qi
MWMuxue Wang
Muxue Wang
XZXiangyu Zhang
Xiangyu Zhang
HSHong Shen
Hong Shen
HWHongyu Wang
Hongyu Wang
CJChongqing Jiao
Chongqing Jiao
The standardised design and operational reliability enhancement of the flexible DC converter valve are impending with the construction of high shares of renewables and power electronics power system. A power frequency magnetic field calculation model able to obtain the electromagnetic disturbance at the submodule (SM) drive board during normal operation of a flexible DC converter valve is presented. Hundreds of SMs with complex structures in a converter valve tower are simplified by the equivalent to the line current to fulfil calculation accuracy requirements. In addition, a random function is employed to simulate the non‐sequential switching process of the SMs. By comparing the calculated results with the measured data obtained from the SM equivalent operation experiment of 2200 V/2150 A, the validity of the calculation model is confirmed. According to the final calculations, the influence of non‐sequential switching cannot be ignored when recognising the time‐domain distribution features of the power frequency magnetic field of the drive board. However, engineering design can be guided only by the power frequency magnetic field intensity of the drive board calculated based on SM’s full removal in the valve tower.

1 August 2023 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
HSHong Shen
Hong Shen
XZXiangyu Zhang
Xiangyu Zhang
LQLei Qi
Lei Qi
SZSheng Zhang
Sheng Zhang
The modular multilevel converter (MMC) will be subjected to transient impacts, such as switch operation in gas-insulated switchgear and wall bushing flashover, resulting in MMC submodules' ports suffering from fast transient overvoltage (FTO), posing a threat to the safe operation of power devices. This letter proposed an FTO suppression method using gap- RC as an additional snubber circuit and provided a method for selecting RC parameters that can reduce the FTO peak to below the device breakdown voltage. Among them, the gap could avoid additional oscillation processes generated by RC during normal operation of the submodule. Finally, an equivalent experimental circuit for the FTO injection submodule port was designed to verify the effectiveness of gap- RC in suppressing FTO.

5 February 2024 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
LQLei Qi
Lei Qi
YLYiyang Liu
Yiyang Liu
XZXiangyu Zhang
Xiangyu Zhang
YLYuanfang Lu
Yuanfang Lu
HSHong Shen
Hong Shen
Press pack power devices serve as critical components in various high-power applications. However, the closed structure of these devices poses challenges in sensing their internal current distribution. This letter addresses this issue by proposing a noninvasive current distribution sensing method based on magnetic field analysis. By strategically placing a limited number of magnetic field sensors near the devices, the proposed method enables the estimation of various forms of nonuniform current distribution. After developing a custom four-point magnetic field measurement setup based on Hall sensors, the current distribution measurement of a commercial insulate gate bipolar transistor (IGBT) under different pressure excursion conditions was performed. Experimental results demonstrate the effectiveness and reliability of the proposed method.

16 November 2021 in High Voltage
Verified
Journal Article
Open access
PDF file
SWSihang Wu
Sihang Wu
HSHong Shen
Hong Shen
LQLei Qi
Lei Qi
BZBei Zhang
Bei Zhang
XCXiang Cui
Xiang Cui
LCLonglong Chen
Longlong Chen
The high current of hybrid DC circuit breaker (HCB) in the process of breaking generates strong transient magnetic field (MF), which may interfere with the normal operation of driver control units (DCUs). Therefore, the analysis for transient MF disturbance is of great significance. Due to the large space scale of HCB, with the large number of power electronic devices, the numerical calculation method has the disadvantages of large consumption of resources and slow calculation speed in solving the transient MF inside the HCB. In this study, the current generation mechanism of a 500 kV HCB is analysed, and the equivalent current path is obtained by considering the skin effect. Combined with the temporal and spatial distribution of transient current, the multi‐process transient equivalent model of transient MF calculation is established, and the model has the advantages of high precision and high speed. Then, the breaking experiment of HCB is carried out, and the transient MF near the DCU is measured. The experiment results verify the validity of the model. Furthermore, the disturbance of transient MF at the DCU of the transfer branch during breaking 25 kA current is analysed.