11 May 2022 in IEEE Transactions on Industrial Electronics
Condition monitoring of insulated gate bipolar transistor (IGBT) modules is an effective way to improve the transient performance and reliability of modular multilevel converters (MMC). This article proposes a novel bond wire failure monitoring method for the multichip IGBT modules in the MMC half-bridge submodule (SM) structure. The collector voltage undershoot V CA(np) of the complementary IGBT switch is measured during the turn- off switching transition of the controlled IGBT switch. V CA(np) is sensitive to the induced voltage over the stray inductance of the IGBT bond wires and provides high sensitivity as a health indicator. The non-intrusive measurement technique is demonstrated using a half-bridge circuit during the turn- off transition of the controlled IGBT, while its complementary switch (i.e., the device under test) is in the off state. Theoretical analysis and experimental results show that the parametric drift due to wire bonding failures can be effectively monitored with high specific relative sensitivity and granularity. To ensure its effectiveness in practical applications, the influence of load current, SM capacitor voltage, and junction temperature is discussed. In addition, a readout circuit is designed featuring the integrated desaturation detection and voltage peak detection, which offers both the short-term overcurrent fault protection and long-term bond wire aging monitoring functions.
20 December 2022 in IEEE Transactions on Power Electronics
Despite that many temperature-sensitive electrical parameters (TSEPs) have been discovered for the online estimation of the junction temperature of IGBT devices, their wide adoption in the field is yet to come. This is because they are most susceptible to both the aging status and operating points of IGBTs, which can result in inaccurate results if not attended. In this study, a novel dynamic TSEP, the gate voltage undershoot V GE(np) of the complementary IGBT switch, is proposed. It is based on the crosstalk effect and measured during the turn- off switching transition of the controlled IGBT switch for its temperature estimation. Its monotonic temperature dependence has been identified with implications for the changing load current and bus voltage, which are experimentally verified using a 1200 V/450 A IGBT module. The theoretical analysis and experimental results also show that V GE(np) is independent of bond wire failures while providing comparatively high relative sensitivity. The MMC power equivalent experimental results are given to verify the feasibility of the proposed method in commercial engineering applications. Finally, the multivariate linear regression method is used to improve the ability to estimate the IGBT's temperature by accounting for the operating point.
16 September 2021 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Introducing bond wire diagnosis for multichip insulated gate bipolar transistor (IGBT) modules is key to the health monitoring of modular multilevel converters (MMCs), which allow for improved field robustness, reliability, and reduced maintenance cost. This article leverages the crosstalk phenomenon during switching transitions to detect the chip open-circuit faults caused by the bond wire lift-off using typical half-bridge IGBT modules in a multichip-parallel configuration. The cycle-controlled, nonintrusive measurement is conducted under normal operation, when the device under test is in OFF-state and its complementary switch is during switching transitions. Two specialized health-sensitive parameters arising from the dynamic gate loop waveforms are identified and evaluated, including: 1) the gate voltage $V_{\mathrm {GE(t3)}}$ when the declining collector voltage reaches zero and 2) the negative peak gate voltage $V_{\mathrm {GE(t4)}}$ . The sensitivity and stability of these two parameters are compared through theoretical analysis, circuit simulation, and practical verification. The results show that $V_{\mathrm {GE(t4)}}$ is more suitable for online monitoring, while $V_{\mathrm {GE(t3)}}$ is more sensitive than $V_{\mathrm {GE(t4)}}$ . With managed complexity in gate drives, this proposed health awareness approach is feasible in the submodules of MMC applications, but it can also be used in other power converter topologies incorporating the half-bridge structure.
4 July 2023 in IEEE Transactions on Power Electronics
Press pack insulated-gate bipolar transistor (PP IGBT) play an essential role in high-capacity power electronic transmission equipment. Due to the influence of various factors such as structural pressure and temperature in practical operation, the internal parallel chips of the IGBT may experience inevitable current imbalance, which can not be detected by existing method. This letter proposes a segmented Rogowski coil (SRC) based non-invasive monitoring method of current imbalance in Press Pack IGBT. By segmenting the standard Rogowski coils around the IGBT device and measuring them individually, the general distribution of the current inside the device can be perceived. After detailed analysis of the mutual inductance characteristics and transfer function, a prototype of SRC was developed. The theoretical model of SRC has been verified by measuring a single current-carrying wire, with an error of only 1.21%. The effectiveness of the proposed scheme was demonstrated by using it to monitor the current distribution in different directions for the same IGBT device.
6 July 2023 in IEEE Transactions on Components, Packaging and Manufacturing Technology
The online detection of aging bond wires is key to the health status awareness of smart power converters. In this paper, a new health precursor of the gate voltage undershoot V GE(pk) of the complementary switch in the half-bridge structure is proposed. It can be used to identify and distinguish multi-site bonding wire failures for both insulated gate bipolar transistors (IGBTs) and freewheeling diodes (FWDs) in multichip IGBT modules. A theoretical analysis is conducted to derive this novel precursor, which is then verified by experimental results. Then, a dedicated read-out circuit is designed for the data acquisition front end that can be integrated into gate drivers for in-situ monitoring. Finally, the effectiveness of this method is evaluated under changing operating conditions including the DC-bus voltage, the load current, and the junction temperature. The effects of their fluctuations are studied and quantified, with corresponding calibration relationships provided to improve precursor accuracy.
12 May 2023 in IET Power Electronics
Capacitance and Insulated gate bipolar transistor (IGBT) junction temperature are two critical healthy parameters for modular multilevel converters (MMC) sub‐modules (SMs) condition monitoring. This paper proposes an integrated monitoring method for capacitance degradation and IGBT junction temperature variation. By measuring multiple characteristics of the same port voltage, the capacitance and the junction temperature can be obtained simultaneously, which greatly simplifies the measurement unit required for condition evaluation and realizes the submodule‐level condition monitoring at a lower cost. The capacitance is characterized by voltage changes during capacitor discharging and the junction temperature is monitored by capacitor voltage overshoot (peak value) during IGBT turn‐off. Theoretical analysis and experimental results verify the effectiveness of the proposed method and articulated the influence of load current, SM capacitor pre‐discharge voltage, and junction temperature. Moreover, an online data‐acquisition circuit for time‐specific capacitor voltage characterization is devised.