Objective: Microvascular anastomosis is challenging, and training surgeons to develop and maintain skills is imperative. Current training models either miss the simulation of the surgical workflow, lack 3D key-hole space, need ethical approval, require special preparation, or lack realism. To circumvent these issues, this study describes the use of a mixed reality 3D printed model with integrated blood flow for training cerebral anastomosis and assesses its validity. Methods: Different-sized 3D-printed artificial micro artery models in a 3D brain space with a keyhole opening were used. The model was connected to a 4D simulator to induce pulsatile blood flow. Neurosurgical microscopes and exoscopes were used for visualization. Nine participants (n = 6 board-certified cerebrovascular neurosurgeons; n = 3 in-training) participated in the study and practiced anastomosis techniques with the simulator. Two senior, experienced vascular neurosurgeons mentored live teaching activity on the simulator. Participants completed a survey to score the face and content validity of the simulation on a 5-point Likert scale. Simulation time and anastomosis score differences between in-training and board-certified participants were compared for construct validity. Results: Participants scored the simulation difficulty similar to actual surgery, proving face validity. All participants agreed that practice on the provided simulator models would improve bypass techniques (μ = 4.67/5 ± 0.47) and instrument handling (μ = 4.56/5 ± 0.68). Board-certified participants had better anastomosis scores than in-training participants (non-significant difference). Conclusions: The 4D simulator and the high-fidelity artificial 3D printed model effectively simulated actual bypass surgery in a key-hole fashion with blood flow abilities. Limited resources and preparation time are needed for the training setup. The model provides benefits in learning and maintaining anastomosis skills and allows for easy adaptation to different microanatomical scenarios.
Despite recent advances in diagnosis and treatment, atherosclerotic coronary artery diseases remain a leading cause of death worldwide. Various imaging modalities and metrics can detect lesions and predict patients at risk; however, identifying unstable lesions is still difficult. Current techniques cannot fully capture the complex morphology-modulated mechanical responses that affect plaque stability, leading to catastrophic failure and mute the benefit of device and drug interventions. Finite Element (FE) simulations utilizing intravascular imaging OCT (Optical Coherence Tomography) are effective in defining physiological stress distributions. However, creating 3D FE simulations of coronary arteries from OCT images is challenging to fully automate given OCT frame sparsity, limited material contrast, and restricted penetration depth. To address such limitations, we developed an algorithmic approach to automatically produce 3D FE-ready digital twins from labeled OCT images. The 3D models are anatomically faithful and recapitulate mechanically relevant tissue lesion components, automatically producing morphologies structurally similar to manually constructed models whilst including more minute details. A mesh convergence study highlighted the ability to reach stress and strain convergence with average errors of just 5.9% and 1.6% respectively in comparison to FE models with approximately twice the number of elements in areas of refinement. Such an automated procedure will enable analysis of large clinical cohorts at a previously unattainable scale and opens the possibility for in-silico methods for patient specific diagnoses and treatment planning for coronary artery disease.