P J Markiewicz

P J Markiewicz

Auto-generated profile, based on publicly available information

P J Markiewicz

School of Cancer and Enabling Sciences, MAHSC, The University of Manchester, Wolfson Molecular Imaging Centre, Manchester, UK

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2009 in NeuroImage
Verified
Journal Article
Closed access
PMP.J. Markiewicz
P.J. Markiewicz
JMJ.C. Matthews
J.C. Matthews
JDJ. Declerck
J. Declerck
KHK. Herholz
K. Herholz

7 October 2011 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PMP J Markiewicz
P J Markiewicz
GAG I Angelis
G I Angelis
FKF Kotasidis
F Kotasidis
MGM Green
M Green
WLW R Lionheart
W R Lionheart
JMJ C Matthews
J C Matthews
This note presents a practical approach to a custom-made design of PET phantoms enabling the use of digital radioactive distributions with high quantitative accuracy and spatial resolution. The phantom design allows planar sources of any radioactivity distribution to be imaged in transaxial and axial (sagittal or coronal) planes. Although the design presented here is specially adapted to the high-resolution research tomograph (HRRT), the presented methods can be adapted to almost any PET scanner. Although the presented phantom design has many advantages, a number of practical issues had to be overcome such as positioning of the printed source, calibration, uniformity and reproducibility of printing. A well counter (WC) was used in the calibration procedure to find the nonlinear relationship between digital voxel intensities and the actual measured radioactive concentrations. Repeated printing together with WC measurements and computed radiography (CR) using phosphor imaging plates (IP) were used to evaluate the reproducibility and uniformity of such printing. Results show satisfactory printing uniformity and reproducibility; however, calibration is dependent on the printing mode and the physical state of the cartridge. As a demonstration of the utility of using printed phantoms, the image resolution and quantitative accuracy of reconstructed HRRT images are assessed. There is very good quantitative agreement in the calibration procedure between HRRT, CR and WC measurements. However, the high resolution of CR and its quantitative accuracy supported by WC measurements made it possible to show the degraded resolution of HRRT brain images caused by the partial-volume effect and the limits of iterative image reconstruction.

1 June 2011 in NeuroImage
Verified
Journal Article
Closed access
PMP.J. Markiewicz
P.J. Markiewicz
JMJ.C. Matthews
J.C. Matthews
JDJ. Declerck
J. Declerck
KHK. Herholz
K. Herholz

16 October 2006 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
MTMahbubunnabi Tamal
Mahbubunnabi Tamal
ARA.J. Reader
A.J. Reader
PMP.J. Markiewicz
P.J. Markiewicz
PJP.J. Julyan
P.J. Julyan
DHD.L. Hastings
D.L. Hastings
Conventional methods for dealing with attenuation and scatter in PET can limit the reconstructed image quality, particularly if the attenuating medium is large (as in whole body 3D PET). In such cases, often a substantial scatter subtraction is performed followed by amplification of the remaining data (to correct for attenuation) resulting in noisy reconstructions. More recent iterative reconstruction methods include the attenuation in the system model in conjunction with either pre-scatter subtraction or a separate addition of the scatter component after each application of the forward model. This work compares these more conventional approaches of including attenuation and scatter to the case where attenuation and scatter information are both included within the system matrix used by the expectation maximization maximum likelihood (EM-ML) algorithm. For this case all acquired data are used and regarded as a source of information by the reconstruction algorithm. Multiple realisations of simulated data sets have been used to compare the performance of the unified attenuation and scatter model with other methods. For a large attenuating medium and low counts there are notable differences between the four main ways of including attenuation and scatter within the reconstruction-with full pre-correction of the data being inferior compared to all the other methods, and the method which models scatter and attenuation within the system matrix showing some advantages. This work suggests that if regularisation of the EM algorithm is carried out by early termination of the iterative process, the subtraction method is the better approach among the techniques considered. In contrast, if a post-reconstruction smoothing approach to regularisation is to be used (whereby highly iterated, noisy image estimates are smoothed), the full modeling method for attenuation and scatter yields the better results, albeit at the computational cost of many more iterations being required

15 May 2011 in NeuroImage
Verified
Journal Article
Closed access
PMP.J. Markiewicz
P.J. Markiewicz
JMJ.C. Matthews
J.C. Matthews
JDJ. Declerck
J. Declerck
KHK. Herholz
K. Herholz